Features
Applications
■ Protects up to eight lines
■ Power Over Ethernet (POE)
■ Fast and easy installation
■ Wireless access points
■ High surge-energy handling
■ IP telephony & cameras
■ Long service life
■ High-speed applications
■ Midspan PSE
7205 Series Standard-Size Surge Protection Assembly
Bourns® standard-size Model 7205 is a high quality surge protection device that is designed to prevent damage to equipment and
personnel from electrical transients up to rated limits. It incorporates Bourns® Gas Discharge Tube (GDT) surge protection for high
surge-energy handling with Insulation Displacement Connectors (IDCs) which simplify installation. Unstripped copper 22-26 AWG
wire is inserted and the connecter is closed – no tools required. The board-mounted components are enclosed in a UL Listed,
weather-resistant enclosure. A #10 stud is provided for connection to ground. The cover may be embossed with an optional custom
logo.
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE80, Telcordia GR-1361.
DC Sparkover ±20% ................................................................100 V/s ........................................................................ 150 V
Impulse Sparkover ...................................................................100 V/μs ...................................................................... 350 V
1000 V/μs .................................................................... 575 V
Impulse Transverse Delay.........................................................1000 V/μs ....................................................................< 75 ns
Insulation Resistance ...............................................................100 V ...........................................................................> 1010 Ω
Glow Voltage ............................................................................10 mA ..........................................................................~ 70 V
Arc Voltage ...............................................................................1 A ...............................................................................~ 10 V
Glow-Arc Transition Current .......................................................................................................................................... < 0.5 A
Capacitance .............................................................................1 MHz ..........................................................................< 2 pF
DC Holdover Voltage1 ..............................................................> 80 V ..........................................................................< 150 ms
Impulse Discharge Current .......................................................20000 A, 8/20 μs .........................................................> 10 operations
1000 A, 10/1000 μs .....................................................> 400 operations
Alternating Discharge Current ..................................................130 Arms, 11 cycles2 .................................................. 1 operation min.
20 Arms, 1 s ................................................................> 10 operations
Operating and Storage Temperature ............................................................................................................................. -40 to +85° C
Notes:
• Model number marking on part: 26-xxx V.
• The rated discharge current is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108 Ω.
• GDT is a UL Recognized component, file E153537.
1
2
Network applied.
DC sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
Europe: Tel: +41-41 768 5555 • Fax: +41-41 768 5510
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
7205 Series Standard-Size Surge Protection Assembly
Product Dimensions
10.2 x 5.1
(.40 x .20)
SLOT
Installation Diagram
RU
170.2
(6.7)
EQUIPMENT
DRIP LOOP
OUTDOOR
ETHERNET CABLE
190.5
(7.5)
160.0
(6.3)
OUTDOOR
SURGE ARRESTER
27.9
(1.1)
139.7
(5.5)
DIMENSIONS:
MM
(INCHES)
GROUND WIRE
GROUND WIRE
GROUND ROD
72.9
(2.87)
How to Order
7205 - 0X - 26 X 15
Model Number Designator
Number of GDTs
07 = Seven
08 = Eight
GDT Type
26 = Model 2026
Fail-Short Option
F = Fail-Short Device
N = No Fail-Short Device
Voltage (Divided by 10)
15 = 150 V
REV. A 03/10
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.