1W DC-DC Converter P1T-Series ● ● ● ● ● ● 16 Pin DIL Wide 2:1 input range Up to 3000 VDC isolation MTBF > 2.7 MHours. Continuous short circuit protection Metal case optional Model selection guide Typ Single output P1T053R3S P1T0505S P1T0509S P1T0512S P1T0515S P1T0524S P1T123R3S P1T1205S P1T1209S P1T1212S P1T1215S P1T1224S P1T243R3S P1T2405S P1T2409S P1T2412S P1T2415S P1T2424S P1T483R3S P1T4805S P1T4809S P1T4812S P1T4815S P1T4824S Dual output P1T053R3D P1T0505D P1T0509D P1T0512D P1T0515D P1T0524D P1T123R3D P1T1205D P1T1209D P1T1212D P1T1215D P1T1224D P1T243R3D P1T2405D P1T2409D P1T2412D P1T2415D P1T2424D P1T483R3D P1T4805D P1T4809D P1T4812D P1T4815D P1T4824D Input voltage range Input current no-load Input current full-load Output voltage Output current min. (1) Output current max. Efficiency typ. @ full load Capacitive output load [VDC] mA] [mA] [VDC] [mA] [mA] [%] [µF] 4.5…9 4.5…9 4.5…9 4.5…9 4.5…9 4.5…9 9…18 9…18 9…18 9…18 9…18 9…18 18…36 18…36 18…36 18…36 18…36 18…36 36...72 36...72 36...72 36...72 36...72 36...72 35 35 40 55 55 70 15 15 15 15 15 15 8 8 8 8 8 8 6 6 6 6 6 6 298 298 285 285 285 294 126 123 116 116 116 119 64 61 60 58 58 60 33 32 31 30 30 31 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 76 50 28 21 17 10 76 50 28 21 17 10 76 50 28 21 17 10 76 50 28 21 17 10 303 200 111 83 67 42 303 200 111 83 67 42 303 200 111 83 67 42 303 200 111 83 67 42 67 67 70 70 70 68 70 72 77 77 77 73 70 72 75 75 75 75 66 68 70 70 70 68 3300 3300 470 470 470 220 3300 3300 470 470 470 220 3300 3300 470 470 470 220 3300 3300 470 470 470 220 4.5…9 4.5…9 4.5…9 4.5…9 4.5…9 4.5…9 9…18 9…18 9…18 9…18 9…18 9…18 18…36 18…36 18…36 18…36 18…36 18…36 36...72 36...72 36...72 36...72 36...72 36...72 35 35 40 55 55 70 15 15 15 15 15 15 8 8 8 8 8 8 6 6 6 6 6 6 298 298 285 285 285 294 119 115 108 108 108 114 59 57 55 55 55 55 31 30 29 29 29 30 ±3.3 ±5.0 ±9.0 ±12.0 ±15.0 ±24.0 ±3.3 ±5.0 ±9.0 ±12.0 ±15.0 ±24.0 ±3.3 ±5.0 ±9.0 ±12.0 ±15.0 ±24.0 ±3.3 ±5.0 ±9.0 ±12.0 ±15.0 ±24.0 ±38 ±25 ±14 ±10 ±8 ±5 ±38 ±25 ±14 ±10 ±8 ±5 ±38 ±25 ±14 ±10 ±8 ±5 ±38 ±25 ±14 ±10 ±8 ±5 ±152 ±100 ±56 ±42 ±33 ±21 ±152 ±100 ±56 ±42 ±33 ±21 ±152 ±100 ±56 ±42 ±33 ±21 ±152 ±100 ±56 ±42 ±33 ±21 70 74 74 75 70 67 70 72 76 76 74 67 70 70 76 77 75 70 70 70 74 76 72 70 2 x 1000 2 x 1000 2 x 220 2 x 220 2 x 220 2 x 100 2 x 1000 2 x 1000 2 x 220 2 x 220 2 x 220 2 x 100 2 x 1000 2 x 1000 2 x 220 2 x 220 2 x 220 2 x 100 2 x 1000 2 x 1000 2 x 220 2 x 220 2 x 220 2 x 100 Suffix: “H” for 3kV isolation voltage (only for plastic case version) (1) Operation without load will not damage these devices, but they will not meet all listed parameters. Page 1 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W DC-DC Converter P1T-Series Part number structure Output power Series P1 1 Watt Input voltage T 05 12 24 48 05 4.5..9 V 9..18 V 18..36 V 36..72 V Output voltage 3R3 3R3 3.3 V 05 5V 7R2 7.2 V 09 9V 12 12 V 15 15 V 18 18 V 24 24 V Outputs S D S single dual Isolation Case H M blanc plastic M metal M only for 1kV blanc H 1 kV 3 kV Remote control C C control Input Page 2 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W DC-DC Converter P1T-Series Specifications Input Absolute max. voltage for 100 ms Filter Isolation: Rated voltage for 60 s, input / output Tested for 3 s Metal case / input & output Resistance Capacitance Output Voltage accuracy Ripple and noise (at 20 MHz BW) Short circuit protection Short circuit restart Current limiting Line voltage regulation Output voltage regulation at 25…100% loading Temperature coefficient 5 V type –0.7..12 VDC 12 V type –0.7..24 VDC 24 V type –0.7..40 VDC 48 V type –0.7..80 VDC Capacitors 1000 VDC, standard 3000 VDC, option “H” 1000 VDC 109 Ω 60 pF, typ. ±2% 80 mVp-p, max. Continuous Automatic 110 % ± 0.5 % ±1% General Switching frequency Safety standard in accordance with Environmental Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity 100...650 kHz IEC60950-1:2001 -40 °C to +85 °C Cooling Physical Dimensions DIP16 Weight Case material standard version Case material metal version Potting material Pin soldering temperature Epoxy UL94-V0 260 C° for 10 s, 1.5 mm distance from body Pin connections 23.4 PHI-CON P1T1205S 10.16 3.05 2.8 17.8 1 23.4 x 14 x 10.16 mm 6 g (Metal version 8 g) non-conductive black plastic, UL94-V0 Copper, nickel plated ± 0.02 % / °C Dimensions 14.0 100 °C, max. -40 °C ... +125 °C See curve Up to 95 %, non-condensing Free-air convection 2 10.2 Ø 0.5 6 11 Dual -V Input -V Input Common -V Output +V Output Common +V Input +V Input Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 4.08 f 9 1.9 2.54 Single -V Input -V Input N.C. N.C. +V Output -V Output +V Input +V Input All dimensions in mm Tolerance ±0.25 mm 8 bottom view 16 15 Pin 1 2 6 8 9 11 15 16 0.5 Page 3 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]