Download

1W DC-DC Converter P1T-Series
●
●
●
●
●
●
16 Pin DIL
Wide 2:1 input range
Up to 3000 VDC isolation
MTBF > 2.7 MHours.
Continuous short circuit protection
Metal case optional
Model selection guide
Typ
Single output
P1T053R3S
P1T0505S
P1T0509S
P1T0512S
P1T0515S
P1T0524S
P1T123R3S
P1T1205S
P1T1209S
P1T1212S
P1T1215S
P1T1224S
P1T243R3S
P1T2405S
P1T2409S
P1T2412S
P1T2415S
P1T2424S
P1T483R3S
P1T4805S
P1T4809S
P1T4812S
P1T4815S
P1T4824S
Dual output
P1T053R3D
P1T0505D
P1T0509D
P1T0512D
P1T0515D
P1T0524D
P1T123R3D
P1T1205D
P1T1209D
P1T1212D
P1T1215D
P1T1224D
P1T243R3D
P1T2405D
P1T2409D
P1T2412D
P1T2415D
P1T2424D
P1T483R3D
P1T4805D
P1T4809D
P1T4812D
P1T4815D
P1T4824D
Input voltage
range
Input current
no-load
Input current
full-load
Output
voltage
Output current
min. (1)
Output current
max.
Efficiency typ.
@ full load
Capacitive
output load
[VDC]
mA]
[mA]
[VDC]
[mA]
[mA]
[%]
[µF]
4.5…9
4.5…9
4.5…9
4.5…9
4.5…9
4.5…9
9…18
9…18
9…18
9…18
9…18
9…18
18…36
18…36
18…36
18…36
18…36
18…36
36...72
36...72
36...72
36...72
36...72
36...72
35
35
40
55
55
70
15
15
15
15
15
15
8
8
8
8
8
8
6
6
6
6
6
6
298
298
285
285
285
294
126
123
116
116
116
119
64
61
60
58
58
60
33
32
31
30
30
31
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
76
50
28
21
17
10
76
50
28
21
17
10
76
50
28
21
17
10
76
50
28
21
17
10
303
200
111
83
67
42
303
200
111
83
67
42
303
200
111
83
67
42
303
200
111
83
67
42
67
67
70
70
70
68
70
72
77
77
77
73
70
72
75
75
75
75
66
68
70
70
70
68
3300
3300
470
470
470
220
3300
3300
470
470
470
220
3300
3300
470
470
470
220
3300
3300
470
470
470
220
4.5…9
4.5…9
4.5…9
4.5…9
4.5…9
4.5…9
9…18
9…18
9…18
9…18
9…18
9…18
18…36
18…36
18…36
18…36
18…36
18…36
36...72
36...72
36...72
36...72
36...72
36...72
35
35
40
55
55
70
15
15
15
15
15
15
8
8
8
8
8
8
6
6
6
6
6
6
298
298
285
285
285
294
119
115
108
108
108
114
59
57
55
55
55
55
31
30
29
29
29
30
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±38
±25
±14
±10
±8
±5
±38
±25
±14
±10
±8
±5
±38
±25
±14
±10
±8
±5
±38
±25
±14
±10
±8
±5
±152
±100
±56
±42
±33
±21
±152
±100
±56
±42
±33
±21
±152
±100
±56
±42
±33
±21
±152
±100
±56
±42
±33
±21
70
74
74
75
70
67
70
72
76
76
74
67
70
70
76
77
75
70
70
70
74
76
72
70
2 x 1000
2 x 1000
2 x 220
2 x 220
2 x 220
2 x 100
2 x 1000
2 x 1000
2 x 220
2 x 220
2 x 220
2 x 100
2 x 1000
2 x 1000
2 x 220
2 x 220
2 x 220
2 x 100
2 x 1000
2 x 1000
2 x 220
2 x 220
2 x 220
2 x 100
Suffix: “H” for 3kV isolation voltage (only for plastic case version)
(1) Operation without load will not damage these devices, but they will not meet all listed parameters.
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W DC-DC Converter P1T-Series
Part number structure
Output power Series
P1
1 Watt
Input voltage
T
05
12
24
48
05
4.5..9 V
9..18 V
18..36 V
36..72 V
Output
voltage
3R3
3R3
3.3 V
05
5V
7R2
7.2 V
09
9V
12
12 V
15
15 V
18
18 V
24
24 V
Outputs
S
D
S
single
dual
Isolation
Case
H
M
blanc plastic
M
metal
M only for 1kV
blanc
H
1 kV
3 kV
Remote control
C
C
control
Input
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W DC-DC Converter P1T-Series
Specifications
Input
Absolute max. voltage for
100 ms
Filter
Isolation:
Rated voltage for 60 s,
input / output
Tested for 3 s
Metal case / input &
output
Resistance
Capacitance
Output
Voltage accuracy
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Current limiting
Line voltage regulation
Output voltage regulation
at 25…100% loading
Temperature coefficient
5 V type –0.7..12 VDC
12 V type –0.7..24 VDC
24 V type –0.7..40 VDC
48 V type –0.7..80 VDC
Capacitors
1000 VDC, standard
3000 VDC, option “H”
1000 VDC
109 Ω
60 pF, typ.
±2%
80 mVp-p, max.
Continuous
Automatic
110 %
± 0.5 %
±1%
General
Switching frequency
Safety standard in
accordance with
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
100...650 kHz
IEC60950-1:2001
-40 °C to +85 °C
Cooling
Physical
Dimensions DIP16
Weight
Case material standard
version
Case material metal
version
Potting material
Pin soldering temperature
Epoxy UL94-V0
260 C° for 10 s, 1.5 mm
distance from body
Pin connections
23.4
PHI-CON
P1T1205S
10.16
3.05
2.8
17.8
1
23.4 x 14 x 10.16 mm
6 g (Metal version 8 g)
non-conductive black
plastic, UL94-V0
Copper, nickel plated
± 0.02 % / °C
Dimensions
14.0
100 °C, max.
-40 °C ... +125 °C
See curve
Up to 95 %,
non-condensing
Free-air convection
2
10.2
Ø 0.5
6
11
Dual
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Life Support Policy: HY-LINE does
not authorize the use of any of its
products for use in life support
devices or systems without the
express written approval of an
officer of the Company. Life support
systems are devices which support
or sustain life, and whose failure to
perform, when properly used in
accordance with instructions for use
provided in the labeling, can be
reasonably expected to result in
significant injury to the user.
Rev: 4.08 f
9
1.9
2.54
Single
-V Input
-V Input
N.C.
N.C.
+V Output
-V Output
+V Input
+V Input
All dimensions in mm
Tolerance ±0.25 mm
8
bottom view
16 15
Pin
1
2
6
8
9
11
15
16
0.5
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]