5W DC-DC Converter P5A-Series
●
●
●
●
Wide 2:1 input range
Up to 3500 VDC isolation
MTBF >1.121 MHours
Continuous short circuit protection
Model selection guide
Typ
Input nominal
voltage
[VDC]
Single output
P5A123R3S
9...18
P5A1205S
9...18
P5A1209S
9...18
P5A1212S
9...18
P5A1215S
9...18
P5A1224S
9...18
P5A243R3S
18...36
P5A2405S
18...36
P5A2409S
18...36
P5A2412S
18...36
P5A2415S
18...36
P5A2424S
18...36
P5A483R3S
36...72
P5A4805S
36...72
P5A4809S
36...72
P5A4812S
36...72
P5A4815S
36...72
P5A4824S
36...72
Dual output
P5A123R3D
9...18
P5A1205D
9...18
P5A1209D
9...18
P5A1212D
9...18
P5A1215D
9...18
P5A1224D
9...18
P5A243R3D
18...36
P5A2405D
18...36
P5A2409D
18...36
P5A2412D
18...36
P5A2415D
18...36
P5A2424D
18...36
P5A483R3D
36...72
P5A4805D
36...72
P5A4809D
36...72
P5A4812D
36...72
P5A4815D
36...72
P5A4824D
36...72
Suffix: “H” for 3.5kV isolation voltage
Output voltage
Output current
Efficiency typ.
[VDC]
[mA]
[%]
Capacitor load
max.
[mA]
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
1300
1000
556
417
333
209
1300
1000
556
417
333
209
1300
1000
556
417
333
209
73
77
78
81
80
80
75
80
82
80
82
82
75
80
82
80
83
83
1000
1000
680
330
220
68
1000
1000
680
330
220
68
1000
1000
680
330
220
68
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±750
±500
±278
±208
±167
±105
±750
±500
±278
±208
±167
±105
±750
±500
±278
±208
±167
±105
73
77
80
80
79
80
75
78
83
80
80
80
73
79
79
80
80
80
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W DC-DC Converter P5A-Series
Specifications
Input
no load current
Filter
Isolation:
Rated voltage (1 minute,
input to output)
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Current limiting
Line voltage regulation
Load voltage regulation
Temperature coefficient
12 V series 30 mADC, typ.
24 V series 20 mADC, typ.
48 V series 12 mADC, typ.
Pi Network
1500 VDC, Standard
3500 VDC, Suffix “H”
9
10 Ω
470 pF, typ.
± 1%
± 1%
60 mVp-p, max.
Continuous (automatic restart)
120% of full load
± 0.5%, max.
± 0.5%, max.
± 1.5%, [email protected] Types
± 0.02% / °C
General
Efficiency
Switching frequency
Safety in accordance with
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical
Dimensions
Weight
Base material
Case material
Absolute maximum ratings
Input voltage < 100 ms
Vin 12 V types
Vin 24 V types
Vin 48 V types
Lead soldering Temperature
73% to 83%
270 kHz, typ.
IEC60950-1:2001
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 95%,
non-condensing
Free-air convection
31.75x20.32x10.16 mm
17 g metal, standard
Epoxy (UL94-V-0 rated)
Standard, nickel-coated
copper metal
-0.7..24 V
-0.7.. 40 V
-0.7..80 V
260°C for 10 s, distance from
package 1.5 mm
Efficiency versus output currrent
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W DC-DC Converter P5A-Series
Dimensions
Pin connections
Pin
2
3
9
11
14
16
22
23
Standard & 3.5kV
Single
Dual
-V Input
-V Input
-V Input
-V Input
Omitted
Common
N.C.
-V Output
+V Output
+V Output
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Life Support Policy: HY-LINE does not
authorize the use of any of its products
for use in life support devices or systems
without the express written approval of
an officer of the Company. Life support
systems are devices which support or
sustain life, and whose failure to perform,
when properly used in accordance with
instructions for use provided in the
labeling, can be reasonably expected to
result in significant injury to the user.
Rev: 02.11 f