6W DC-DC Converter P6B-Series
●
●
●
●
●
●
Wide 4:1 input range
-40...+85°C operation temperature range
Isolation up to 3500 VDC
MTBF > 1.12 MHours
Continuous short circuit protection
Efficiency up to 84%
Model guide
Type
Single output
P6B243R3S
P6B2405S
P6B247R2S
P6B2409S
P6B2412S
P6B2415S
P6B2418S
P6B2424S
P6B483R3S
P6B4805S
P6B487R2S
P6B4809S
P6B4812S
P6B4815S
P6B4818S
P6B4824S
Dual output
P6B243R3D
P6B2405D
P6B247R2D
P6B2409D
P6B2412D
P6B2415D
P6B2418D
P6B2424D
P6B483R3D
P6B4805D
P6B487R2D
P6B4809D
P6B4812D
P6B4815D
P6B4818D
P6B4824D
Input voltage
range
[VDC]
Input current
No-load
Full-load
[mA]
[mA]
Output
voltage
[VDC]
Output current
Efficiency typ.
[mA]
[%]
Capacitive
load (*1)
[µF]
9...36
9...36
9...36
9...36
9...36
9...36
9...36
9...36
18...72
18...72
18...72
18...72
18...72
18...72
18...72
18...72
12
10
18
12
15
18
15
18
15
10
15
10
10
10
10
12
253
312
312
300
300
300
300
305
130
156
155
155
150
149
150
150
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
0...1400
0...1200
0...833
0...666
0...500
0...400
0...333
0...250
0...1400
0...1200
0...833
0...666
0...500
0...400
0...333
0...250
76
80
80
83
83
83
83
82
76
80
80
82
83
84
83
83
1000
1000
470
220
100
47
47
47
1000
1000
470
220
100
47
47
47
9...36
9...36
9...36
9...36
9...36
9...36
9...36
9...36
18...72
18...72
18...72
18...72
18...72
18...72
18...72
18...72
12
10
18
18
20
22
18
18
10
10
15
15
10
15
15
15
340
315
315
310
300
305
305
315
165
160
155
155
150
150
155
155
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
0...±910
0...±600
0...±416
0...±333
0...±250
0...±200
0...±166
0...±125
0...±910
0...±600
0...±416
0...±333
0...±250
0...±200
0...±166
0...±125
74
80
80
81
83
82
82
80
77
79
80
81
82
84
80
81
2 x 470
2 x 680
2 x 220
2 x 100
2 x 100
2 x 100
2 x 22
2 x 22
2 x 470
2 x 680
2 x 220
2 x 100
2 x 100
2 x 100
2 x 22
2 x 22
Add suffix “H” for 3.5 kV isolation voltage
Add suffix “P” for plastic case
Page 1 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6B-Series
Specifications
Input :
Filter
Input reflected ripple current
Isolation:
Rated voltage
Input / output 3 sec.
Input or output to case 3 sec.
Resistance input to output
Capacitance
Output:
Voltage accuracy
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple and noise
(at 20 MHz BW)
Short circuit protection
General:
Switching frequency
Safety in accordance with
Reliability calc. MTBF
Environmental:
Operating temperature
Storage temperature
Case temperature max.
Derating
Humidity
Cooling
Physical :
Dimensions
Weight
Case material
Pi Network
35 mAp-p (*2)
Standard. 1500 VDC
Suffix “H”: 3500 VDC
1000 VDC
9
10 Ω
500 pF, typ.
±1%
± 0.5 %, max.
± 0.5 %, max.
P6Bxx3R3x: 1.5 %, max.
± 0.02 % / °C
60 mVp-p, max. (*3)
Continuous, automatic restart
270 kHz, typ.
IEC 60950-1
1.12 Mio. h, MIL-HDBK-217 F
EMI filter circuit
Potting material
EMC in accordance with
Radiated emissions
Conducted emissions
ESD
RS
EFT
Surge (*5)
CS
PFMF
Absolute maximum ratings
Input voltage P6B24xxx
P6B48xxx
Soldering temperature
+ Vin
-40…+85 °C ambient
-40…+125 °C
100 °C
see diagram
95 %, max., not condensing
Free air convection
31.75 x 20.32 x 10.16 mm
Metal 17 g, Plastic 14 g
Nickel coated copper
Suffix “P”: Plastic
UL94V-0 rated epoxy resin
EN55022 class A
EN55022 class A (*4)
IEC61000-4-2 perf. criteria A
IEC61000-4-3 perf. criteria A
IEC61000-4-4 perf. criteria A
IEC61000-4-5 perf. criteria A
IEC61000-4-6 perf. criteria A
IEC61000-4-8 perf. criteria A
-0.7...+40 Vp, 0.1 s max.
-0.7...+80 Vp, 0.1 s max.
260 °C for 10 s
distance 1.5 mm from case
Note:
All specifications at Ta 25 °C, nominal input voltage
and full load unless otherwise specified!
L 12 µH
C1
C2
68 µF
33 µF
ESR <1 Ω
at 100 kHz
Load
- Vin
*1 Test by nominal input voltage and constant resistor
load
*2 Measured input reflected ripple current with a
simulated source inductance of 12 µH
*3 Typical value at nominal input voltage, full load and
output ceramic chip capacitor 1 µF
Test circuit for reflected input ripple current
*4 It is recommended to add C1, C2 and L on input
and to achieve EN 55022 conducted class A,
see “EMI filter circuit”
oscilloscope current probe
+ Vin
4.7µH
Measure
point
*5 Only with external input capacitor 220 µF, 100 V,
Nippon Chemicon, KY series
47 µF
ESR <1 Ω
at 100 kHz
Load
- Vin
Test circuit for output ripple and noise
+Vout
Cout
1 µF
Resistive
load
Measure
points for
oscilloscope
-Vout
Page 2 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6B-Series
Page 3 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6B-Series
Dimensions (metal case)
Pin connections
Pin
2
3
9
11
14
16
22
23
Isolation 1.5 / 3.5 kVDC
Single
Dual
-V Input
-V Input
-V Input
-V Input
Omitted
Common
N.C.
-V Output
+V Output
+V Output
-V Output
Common
+V Input
+V Input
+V Input
+V Input
PHI-CON is a trademark of HY-LINE Holding GmbH.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions
carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user. Rev: 01.15 f
Page 4 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages