Download

Data Sheet – EFOY Pro Fuel Cells
EFOY Pro 800
EFOY Pro 800
Duo
EFOY Pro 2400
EFOY Pro 2400
Duo
45 W
45 W
110 W
110 W
25 W
25 W
80 W
80 W
12 V dc / 24 V dc
12 V dc / 24 V dc
12 V dc / 24 V dc
12 V dc / 24 V dc
max.:
3,75 A / 1,88 A
3,75 A / 1,88 A
9,17 A / 4,58 A
9,17 A / 4,58 A
min.:
2,1 A / 1,05 A
2,1 A / 1,05 A
6,7 A / 3,3 A
6,7 A / 3,3 A
Recommended battery capacity 2 at 12 V
40 to 160 Ah
40 to 160 Ah
60 to 350 Ah
60 to 350 Ah
(Lead acid, gel and AGM)
10 to 100 Ah
10 to 100 Ah
30 to 175 Ah
30 to 175 Ah
8,0 kg / 17.6 lbs
8,3 kg / 18.3 lbs
9,0 kg / 19.8 lbs
9,3 kg / 20.5 lbs
24 Month /
24 Month /
24 Month /
24 Month /
4.500 hours
4.500 hours
4.500 hours
4.500 hours
1 (2)
2 (4)
1 (2)
2 (4)
Fuel Cells
Max. nominal power
Min. nominal power
1
Nominal voltage
Charging current at 12 V / 24 V
at 24 V
Weight
Warranty 3
Connectable cartridges (with DCS1)
Length fuel cartridge connector
70 cm / 27.6 in
Switching threshold for automatic
battery charging at 12 V / 24 V 4
On: <12,3 V / <24,6 V
Off: >14,2 V / >28,4 V
Required start-up voltage at 12 V /24 V
>9 V / >18,5 V
Maximum battery voltage
<16 V / <32 V
Noise level (at 1m / 7m distance)
42 dB(A) / 25 dB(A)
Nominal consumption 5
0,9 l/kWh
Quiescent current draw at 12 V
20 mA
Operating temperature
-20 °C to +50 °C / -4°F to +122°F
Start-up temperature
+3 °C to +50 °C / +37.4 °F to +122°F
Storing temperature
Recommended altitude
+1 °C to +50 °C / +34°F to +122°F
4
Standard: ≤1500 m / ≤4920 ft (up to 2000m / 6561 ft)
Dimensions L x W x H
433 x 188 x 278 mm / 17 x 8 x 11 in
International Protection (IP-Class)
Inclination along the roll axis
IP 21
Permanent: max. 35°; temporary (<10 min): max. 45°
Inclination along the lateral axis
Permanent: max. 20°
User-Interface
At the unit or via Operating Panel OP2 with text display
Data-Interface
RJ-45 plug for accessories (e.g. Interface adapter)
Electrical Interface
MNL-plug 4-pins (e.g. Tyco Electronics Universal Mate-N-Lok – Nr. 350779)
Certificates
Standard Equipment
 Operating panel OP2 with cable
 Exhaust hose
 Mounting plate for EFOY Pro
 Off heat duct
 Charge line for battery connection
 Service fluid and user manual
 Fuel cartridge holder with belt
SFC Energy AG
Tel.: +49 89 673 592 – 0
Fax: +49 89 673 592 – 369
Email: [email protected]
Web: www.efoy-pro.com
All technical data at test conditions of 20 °C / 68 °F
Data sheet not valid in USA and Canada
Subject to modifications and errors
Valid from: 03rd April 2013
1/2
Data Sheet – EFOY Pro Fuel Cells
Accessories 6
DuoCartSwitch DCS1
Dimensions L x W x H
174 x 119 x 96 mm / 6.9 x 4.7 x 3.8 in
Weight
0,7 kg / 1.54 lbs
International Protection (IP-Class)
IP 20
Quiescent current draw
GSM modem GSM-2-SMS
7.5 mA
Dimensions L x W x H
72 x 32 x 65 mm / 2.8 x 1.3 x 2.6 in
Weight
0,5 kg / 1.1 lbs
Input Voltage
8 – 30 V dc
Max. peak current
3,2 A
Average current draw (Quiescent / SMS / GPRS)
30 / 100 / 100 mA
Fuel cartridge sensor FS1
Dimensions L x W x H
50 x 20 x 5 mm / 19.7 x 7.9 x 2.0 in
Interface adapter IA1
Dimensions L x W x H
60 x 33 x 16 mm / 2.4 x 1.3 x 0.6 in
Dimensions L x W x H
149 x 77 x 270 mm / 58.7 x 30.1 x 106.3 in
Cluster controller CC1
Weight
M28 adapter
0,16 kg / 1.3 lbs
Dimensions L x W x H
70 x 70 x 61 mm / 2.8 x 2.8 x 2.4 in
Fuel Cartridges
M5
M10
M28 (only with M28-Adapter)
Volume
Weight
Nominal capacity
Dimensions L x W x H
5 litre / 1.32 US gallons
4,3 kg / 9.5 lbs
5,5 kWh
190 x 145 x 283 mm /
7.5 x 5.7 x 11.1 in
10 litre / 2.64 US gallons
8,4 kg / 18.5 lbs
11,1 kWh
230 x 193 x 318 mm /
9.1 x 7.6 x 12.5 in
28 litre / 7.4 US gallons
22 kg / 48.5 lbs
31,1 kWh
370 x 285 x 395 mm / 14.6 x 11.2 x 15.6 in
with M28 Adapter:
370 x 285 x 425 mm / 14.6 x 11.2 x 16.7 in
1
Nominal power varies by ±10 %, decreases with the operation hours. Specification valid within warranty period.
Depends on battery type and application - bigger batteries possible, if additional energy source available (e.g. solar)
3
Regional warranty conditions for EFOY Pro fuel cells apply.
4
Factory Setting - can be modified with Interface Adapter and PC or operating panel OP2.
5
Effective consumption depends on operating conditions.
6
All EFOY Pro accessories are for operating in following temperature ranges: -20 °C to +50 °C / -4 °F to +122°F
2
SFC Energy AG
Tel.: +49 89 673 592 – 0
Fax: +49 89 673 592 – 369
Email: [email protected]
Web: www.efoy-pro.com
All technical data at test conditions of 20 °C / 68 °F
Data sheet not valid in USA and Canada
Subject to modifications and errors
Valid from: 03rd April 2013
2/2