Features Applications ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ GDT/TBU® High-Speed Protector technology Low impulse let-through High surge current rating Available in isolated and grounded versions 10/100/1000 data compatibility 5 kV isolation Listed per UL 497B (File: E153537) Data communications Highly exposed Ethernet 1000 Base-T Gigabit Ethernet Indoor/controlled environment installations Telecommunications and industrial installations 1500 Series Gigabit Ethernet SPD The 1500 Series Ethernet Surge Protective Device (SPD) incorporates multiple Bourns® circuit protection technologies. These technologies are designed to work together to provide an unmatched level of surge protection for exposed Ethernet applications. The 1500 Series is designed to meet key surge and AC power cross requirements of GR-1089-Core Issue 6. The isolated model is designed to withstand voltages up to 5 kV. The 1500 Series is available as a wall mount unit with optional DIN Rail hardware. Characteristics Test methods per UL 497B, GR-1089 Issue 6, and CSA C22.2. Parameter DC Breakdown Line to Line DC Breakdown Line to Ground Line Series Resistance (Loop) Line Series Balance Capacitance Line to Line @ 1 MHz Time-to-block (tblock) First Level Surge 1 kV – 10/1000 μs, 100 A 2.5 kV – 2/10 μs, 500 A 800 V – 1.2/50 μs, 8/20 μs Combo Wave Second Level Surge 2.5 kV – 2/10 μs, 500 A, Inductive Kick 6 kV / 3 kA – 1.2/50 μs, 8/20 μs Combo Wave First Level Power Fault 220 mA Below Protection Threshold 600 V / 1 A / 1 Second 1000 V / 1 A / 1 Second 425 V / 0.5 A / 4 Seconds Second Level Power Fault 120 V / 25 A 1 425 V / 40 A / 1.5 Second 1 425 V / 7 A / 5 Seconds 1 425 V / 2.2 A BER Performance Testing 10/100 Mbps 1 Gbps Storage and Operating Temperature Ground Connection Isolated Version Grounded Version 150 V Typical Input / 7 V Typical Output N/A 150 V Typ. 12 Ω Typ. 0.5 Ω Typ. / 1.0 Ω Max N/A 10 pF Typ. <1 μs >10 operations >10 operations >10 operations > 1 operation > 1 operation 15 minutes > 60 operations > 60 operations > 1 operation 15 minutes 1 operation 1 operation 15 minutes > 100 meters Up to 100 meters -40 to +65 °C Screw Lug or DIN Rail Clip Notes: Isolated version does not require a ground connection. 1) Fuse may fail open and disconnect from circuit. Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116 EMEA: Tel: +36 88 520 390 • Fax: +36 88 520 211 The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700 www.bourns.com Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. 1500 Series Gigabit Ethernet SPD Product Dimensions DIN Rail Hardware Dimensions 65.10 (2.563) 25.12 (0.989) 107.01 (4.213) 15.75 (0.62) 40.64 (1.60) 46.48 (1.83) DIMENSIONS: MM (INCHES) 16.25 (0.65) How To Order 1500 - X Y - W Model Number Designator Configuration 1 = Isolated* 2 = Grounded Hardware Options S = Screw Lug D = DIN Rail Ground Wire (Optional) W = #14 AWG Ground Wire, 3 Ft. * Isolated unit requires no ground. REV. C 04/15 “Bourns” is a registered trademark of Bourns, Inc. in the United States and other countries. “TBU” is a registered trademark of Bourns, Inc. in the U.S. and other countries, except Japan. All references to TBU® in this document for use in Japan shall be deemed to be replaced with Bourns® TBU™. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications.