303M Hybrid Series

Features
■ True hybrid technology vs. hybrid with MOV
backup
This model is available but not
recommended for new designs.
The 2410, 2420 and 2430 Series
are preferred.
■ Self-resetting sneak current protection
■ Long service life
■ GR-974-CORE Issue 3 compliant - medium
voltage limiting (600 volts maximum over
life vs. 1000 volts maximum for gas tube
alone)
Model 303M Hybrid 5-Pin Protector Modules
The Bourns® Hybrid 5-Pin Protector Module design combines solid-state semiconductor technology and gas tube technology. The
hybrid protector (gas tube with coordinated MOV) provides the fastest response to damaging overvoltage transients as well as high
energy handling capability.
The hybrid design technology provides optimum overvoltage protection for both primary and secondary protection applications. Since
the hybrid is designed as a 5-pin configuration, it can easily be interchanged with all other standard 5-pin protectors.The hybrid design
also includes a fail-safe mechanism that operates under sustained or high-current power cross conditions to permanently short the line
to ground.
The hybrid design provides protection for data transmission over copper pairs. The solid-state semiconductor technology combined with
the gas tube technology will allow the hybrid protector to respond quickly to protect sensitive equipment.The hybrid is ideal for
providing protection for broadband voice and data circuits (ADSL, ADSL 2+, VDSL2) due to its solid-state speeds and low capacitance.
The Bourns® Hybrid 5-Pin Protector Module is also available with an option for a positive temperature coefficient (PTC) device to
provide resettable sneak current protection.This feature protects digital equipment line cards against overheating caused by prolonged
currents (commonly called sneak currents). Sneak currents are often caused by direct contact with low-voltage power lines; they may
result from induction on telephone lines caused by fault currents, overloads or unbalanced loads on nearby power lines. The Bourns®
Hybrid 5-Pin PPTC Resistor Module is unique in design because it has minimal signal loss in the ADSL, ADSL 2+, VDSL, CAT 3 and
higher frequency ranges.
Specifications
E
T
E
L
O
S
B
O
Insertion Loss
Hybrid – no sneak current ...................................................0-26 MHz ............................................. < 0.1 dB
Hybrid – no sneak current ...................................................0-42 MHz ............................................. < 0.3 dB
Hybrid with sneak current ...................................................0-50 MHz ............................................. < 0.4 dB
Hybrid with sneak current ...................................................0-90 MHz ............................................. < 0.9 dB
Resistance (sneak current).......................................................4.5 Ohms Max.
Hybrid with sneak current imbalance........................................< 0.5 Ohms
Response time (with sneak current)
+65 ºC .................................................................................Operates within 210 seconds .............. 300 mA
+20 ºC .................................................................................Operates within 210 seconds .............. 540 mA
-40 ºC ..................................................................................Operates within 210 seconds .............. 800 mA
Hold Time (with sneak current)
Hold for > three hours .........................................................100 mA for -40, +20 and +65 ºC
Hold for five seconds ..........................................................260 mA for -40, +20 and +65 ºC
DC Limiting Voltage ..................................................................-40 ˚C, +20 ˚C, +65 ˚C ........................ 350 V at 2000 V/sec
Leakage Current (Rated Voltage)
(Minimum Voltage Limit) ...........................................................-40 ˚C, +20 ˚C, +65 ˚C ........................ 20 mA max. at 265 VDC,
100 V/µsec
Impulse Breakdown (Vimp) .......................................................-40 ˚C, +20 ˚C, +65 ˚C ........................ 500 V max. at 100 V/µsec
600 V max at 1000 V/µsec
Insulation Resistance (IR) ........................................................-40 ˚C, +20 ˚C, +65 ˚C ........................ 1000 Mohms min. at
50 to 200 VDC
DC Holdover (Impulse Reset)
@ 260 mA, ±52.5 VDC .......................................................-40 ˚C, +20 ˚C, +65 ˚C ........................ 20 ms max.
@ 200 mA, ±135 VDC ........................................................-40 ˚C, +20 ˚C, +65 ˚C ........................ 20 ms max.
@ 1.0 A, ±135 VDC (1.0 µF Network Capacitance) ............25 ms max.
@ 450 mA, ±135 VDC (0 µF Network Capacitance)...........90 ms max.
Impulse Life (-20 °C, +65 °C) Criteria: ......................................±10 A, 10/1000 µsec ........................... 1500 surges
IR>109 and at 50 VDC .............................................................±100 A, 10/1000 µsec ......................... 100 surges
Limiting Voltage during Surge <600 V .....................................±300 A, 10/1000 µsec ......................... 50 surges
Impulse Reset/DC Holdover < 30 ms .......................................±2000 A, 10/250 µsec ......................... 5 surges
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Features (Continued)
■ Exceeds GR-974 requirements for central
office protection by meeting station
protection requirements
■ Compatible with temperature extremes in
the outside plant environment
■
Listed
Model 303M Hybrid 5-Pin Protector Modules
Specifications (Continued)
End-of-Life Criteria
100 V/µs Breakdown < 1000 V ...........................................±10 A, 10/1000 µsec ........................... 3000 surges
±100 A, 10/1000 µsec ......................... 300 surges
±300 A, 10/1000 µsec ........................ 100 surges
±500 A, 10/1000 µsec ........................ 500 surges
±2000 A, 10/250 µsec ........................ 100 surges
±5000 A, 20/100 µsec ........................ 10 surges
±20000 A, 8/20 µsec .......................... 1 surge
120 A, 0.1 sec ..................................... 1 surge
AC Life, 60 Hz ..........................................................................10 Arms, 1 sec...................................... 5 surges
1 Arms, 1 sec........................................ 60 surges
0.5 A, 30 sec ....................................... 1 surge
Safety .......................................................................................60 A, 3 sec .......................................... Fail-safe
120 A, 0.6 sec .................................... Does not cause a fire hazard
350 A, 0.04 sec .................................. Does not cause a fire hazard
30 A, 15 min ....................................... Fail-safe, does not cause a fire
hazard
Capacitance........................................................................................................................................... 35 pF max.
Storage and Operating Temperature ........................................-40 ˚C to + 65 ˚C
Safety Standards Listing........................................................................................................................ cULus
E
T
E
L
O
S
B
O
Notes: All values at 20 ˚C except where noted.
Nominal voltages provided, except where noted.
Frequency Distribution of Impulse Breakdown Voltages (100 V/μs)
SSOVP, Hybrid, Gas and Carbon
(New Condition)
60
Percentage of Breakdown
Hybrid
SSOVP
50
40
30
Gas
20
Carbon
10
0
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
Breakdown Voltage
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 303M Hybrid 5-Pin Protector Modules
Frequency Distribution of Impulse Breakdown Voltages (100 V/μs)
SSOVP, Hybrid, Gas and Carbon
(Over Time)
60
SSOVP
Percentage of Breakdown
50
Hybrid
40
30
G as
20
E
T
E
L
O
S
B
O
Carbon
10
0
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
Breakdown Voltage
How to Order
Part Number
303M-07G1G0
303M-07G3G0
303M-07H1G0
303M-07H3G0
303M-07G1T0
303M-07G3T0
303M-07H1T0
303M-07H3T0
303M-09G1G0
303M-09G3G0
303M-09H1G0
303M-09H3G0
303M-09G1T0
303M-09G3T0
303M-09G1GP
303M-09G3GP
303M-09H1GP
303M-09H3GP
303M-09G1TP
303M-09G3TP
Description
5-Pin Hybrid, 350 V, gold pins, black case
5-Pin Hybrid, 350 V, gold pins, red case
5-Pin Hybrid, 350 V, gold pins, black case, front test
5-Pin Hybrid, 350 V, gold pins, red case, front test
5-Pin Hybrid, 350 V, tin pins, black case
5-Pin Hybrid, 350 V, tin pins, red case
5-Pin Hybrid, 350 V, tin pins, black case, front test
5-Pin Hybrid, 350 V, tin pins, red case, front test
5-Pin Hybrid, 350 V, gold pins, black case
5-Pin Hybrid, 350 V, gold pins, red case
5-Pin Hybrid, 350 V, gold pins, black case, front test
5-Pin Hybrid, 350 V, gold pins, red case, front test
5-Pin Hybrid, 350 V, tin pins, black case
5-Pin Hybrid, 350 V, tin pins, red case
5-Pin Hybrid, 350 V, gold pins, black case, with PPTC
5-Pin Hybrid, 350 V, gold pins, red case, with PPTC
5-Pin Hybrid, 350 V, gold pins, black case, front test, with PPTC
5-Pin Hybrid, 350 V, gold pins, red case, front test, with PPTC
5-Pin Hybrid, 350 V, tin pins, black case, with PPTC
5-Pin Hybrid, 350 V, tin pins, red case, with PPTC
For additional information or ordering assistance, please contact Bourns Inside Sales at [email protected].
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 303M Hybrid 5-Pin Protector Modules
Product Dimensions
Part Number
303M-07G1G0
303M-07G3G0
303M-07H1G0
303M-07H3G0
303M-07G1T0
303M-07G3T0
303M-07H1T0
303M-07H3T0
303M-09G1G0
303M-09G3G0
303M-09H1G0
303M-09H3G0
303M-09G1T0
303M-09G3T0
Test Points
No test
No test
Test
Test
No test
No test
Test
Test
No test
No test
Test
Test
No test
No test
Type
3B1H
3B3H
3C1H
3C3H
3B1H
3B3H
3C1H
3C3H
3B1H
3B3H
3C1H
3C3H
3B1H
3B3H
Figure
1
1
2
2
1
1
2
2
3
3
4
4
3
3
Part Number
303M-09G1GP
303M-09G3GP
303M-09H1GP
303M-09H3GP
303M-09G1TP
303M-09G3TP
Test Points
No test
No test
Test
Test
No test
No test
E
T
E
L
O
S
B
O
Type
4B1H
4B3H
4C1H
4C3H
4B1H
4B3H
Figure
3
3
4
4
3
3
Test
Points
42
(1.65)
18
(0.75)
10
(0.4)
12.7
(0.50)
46
(1.80)
10
(0.4)
18
(0.75)
12.7
(0.50)
Figure 1
Figure 2
Test
Points
54.4
(2.14)
10
(0.4)
18
(0.75)
10
(0.4)
18
(0.75)
12.7
(0.50)
DIMENSIONS:
54.4
(2.14)
12.7
(0.50)
MM
(INCHES)
REV. C 01/13
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.