PL IA NT Features CO M ■ *R oH S ■ ■ ■ ■ ■ Industry standard SIP package Output voltage programmable from 0.75 Vdc to 5.5 Vdc via external resistor 3 A output current Up to 95 % efficiency Small size, low profile Cost-efficient ■ ■ ■ ■ Low output ripple and noise High reliability Remote on/off Output overcurrent protection (non-latching) SX3A-12SA(-P) SIP Non-Isolated Power Module Description Bourns® Model SX3A-12SA(-P) is a non-isolated DC-DC converter offering designers a cost and space-efficient solution with standard features such as remote on/off, precisely regulated programmable output voltage and overcurrent protection. Specifications Parameter Min. Nom. Max. Units Notes 8.3 12 14 Vdc Adc 18 V max. for -W version INPUT Voltage Current Remote ON/OFF: Low or Open = High = 2.0 Standard On Off OUTPUT Voltage Adjustment Range Current Voltage Setpoint Accuracy Line Regulation Load Regulation Temperature Regulation E T E L O S B O -P Option Off On 2.4 0.4 Vin Vdc Vdc 0.75 5.5 Vdc 0.0 3.0 -2.5 2.5 Adc % Vo,set 0.3 % Vo,set 0.4 % Vo,set 0.4 10 µA max. 1 mA max. Ripple (pk-pk) (20 MHz Bandwidth) 30 50 % Vo,set mVpk-pk 1 µF ceramic//10 µF tantalum capacitors Ripple (rms) 10 15 mVrms 1 µF ceramic//10 µF tantalum capacitors 1 µF ceramic//10 µF tantalum capacitors Dynamic Load Response: 50 % to 100 % Load or 100 % to 50 % Load; (∆i/∆t = 2.5 A/µs; 25 °C) 200 25 mV µs 50 % to 100 % Load or 100 % to 50 % Load; (∆i/∆t = 2.5 A/µs; 25 °C) 75 100 mV µs 13,000 kHrs 0 to +85 °C 2 x 100 µF polymer capacitors GENERAL MTBF Operating Temperature -40 +85 °C Storage Temperature -55 +125 °C Switching Frequency 300 kHz Efficiency 86.0 % Vo,set = 1.2 Vdc 88.0 % 90.0 % Vo,set = 1.5 Vdc Vo,set = 1.8 Vdc 91.0 % Vo,set = 2.5 Vdc 93.0 % Vo,set = 3.3 Vdc 95.0 % Vo,set = 5.0 Vdc (Vin = 12 Vdc, TA= 25 °C, Full Load) Applications ■ ■ ■ Intermediate Bus architecture Distributed power applications Workstations and servers ■ ■ ■ Telecom equipment Enterprise networks including LANs/WANs Latest generation ICs (DSP, FPGA, ASIC) and microprocessor powered applications *RoHS Directive 2002/95/EC Jan 27 2003 including Annex. Specifications are subject to change without notice. Customers should verify device performance in their specific applications. Output Voltage Programming Via external trim resistor between Trim and GND: Rtrim = [ Via application of external voltage between Trim and GND: ] 10.5 - 1.0 kΩ Vo - 0.7525 Vtrim = (0.7 - 0.0667 x {Vo - 0.7525}) SX3A-12SA(-P) SIP Non-Isolated Power Module Product Dimensions Recommended Hole Pattern BACK VIEW OF BOARD COMPONENT SIDE FOOTPRINT 22.9 (0.90) 23.4 (0.92) OUTLINE AREA 10.2 (0.40) 9.8 (0.385) 5 4 3 2 1 5 PINS Die-Tech 315-0969-00 0.64 0.38 X (0.025) (0.015) 4.9 (0.19) 5.7 (0.23) 1.5 (0.06) 2.54 (0.100) 7.6 (0.30) E T E L O S B O 1.09 (0.043) PLATED THROUGH-HOLE 1.63 (0.064) PAD SIZE BOTH SIDES 15.24 (0.600) 17.78 (0.700) 1.3 (.005) 2.54 (0.100) 20.32 (0.800) 15.24 (0.600) 17.78 (0.700) 20.32 (0.800) Pinout Detail PIN 1 2 3 4 5 SIDE VIEW 6.6 (0.260) MAX. 6.36 (0.250) REF. DIMENSIONS: MM (INCHES) L1 (REF.) FUNCTION VOUT TRIM GND VIN ON/OFF How to Order S X 3A - 12 S A (-P) Configuration • S = SIP TOLERANCES: 0.5 (0.02) 0.25 DECIMAL .XX ± (0.010) DECIMAL .X ± Internal Identifier Output Current (Amps) Input Voltage (V) Outputs • S = Single Output Voltage (V) • A = Adjustable 0.64 (0.025) 4.62 (0.182) Optional Positive On/Off Logic Fixed output voltage parts and optional features available; contact factory. Derating Output Current vs. Local Ambient Temp & Airflow (Vin = 12 Vdc, Vo = 3.3 Vdc) 3.5 Output Current (A) 3.0 2.5 NC (0 LFM) 2.0 1.5 Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116 Europe: Tel: +41-41 768 5555 • Fax: +41-41 768 5510 The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700 www.bourns.com 1.0 0.5 0.0 25 30 35 40 45 50 55 60 65 70 Ambient Temperature (°C) 75 80 85 REV. A 11/06 Specifications are subject to change without notice. Customers should verify device performance in their specific applications.