Sentinel Command Workstation

Sonardyne Global Headquarters
T. +44 (0) 1252 872288
F. +44 (0) 1252 876100
E. [email protected]
www.sonardyne.com
Datasheet
Sentinel Command Workstation
Description
The Command Workstation is
composed of three, separate, 2U
high units: the System Router (SRU);
Control & Display Processor (C&D);
and the slide-out display. Each of
these components is a COTS based
ruggedized item.
Display Images, Track Data and
System Status are received by the
System Router from each Sonar
Router uplink, with the internal switch
transferring this data to the C&D,
where it is aggregated and prepared
for display. Raw data from all
sonars is overlaid on either a
calibrated background image
(satellite photograph or chart) or a
blank background. Tracks are
assigned colours and symbols based
on alert-state and classification and
placed as the top layer above raw
sonar and background images.
A user interface is provided, along
with a mouse and keyboard, that
allows the operator to configure the
system, control its operation and
request further detail on a selected
track.
The Sentinel Control & Display
software also provides servers for
track, status and display data as well
as remote control; traffic to these is
routed, via the System Router, to an
external uplink port for connection to
an external Command and Control
system.
Router and the C&D SPU is
configured to auto-start on power-up.
The slide-out display is a ruggedized
LCD panel, supporting resolutions up
to 1280x1024. It is a full marine
grade display with high viewing
angles and high contrast even in
high ambient light conditions.
Key Features
• Ruggedised COTS Based
Processing
• Standard 19”/482.6mm IEC
60297 Rack Mounting
The Sentinel Processing Unit (SPU)
used is configured at runtime in the
C&D role by use of a coded dongle
and, in keeping with the rest of the
system, is fully interchangeable with
any other SPU.
• Performs system control and
provides user interface
Power for the C&D and the slide-out
display is supplied via the System
• Switchable Power Input,
115/230 V
• Exports tracks, status and images
to external Command and Control
• Includes marine grade LCD panel
Sonardyne Global Headquarters
T. +44 (0) 1252 872288
F. +44 (0) 1252 876100
E. [email protected]
www.sonardyne.com
Specifications
Sentinel Command Workstation
System Router
Front
System Router
Back
C&D Front
C&D Rear
Feature
Power Supply
Environmental
Specifications
Dimensions (LxWxH)
Operating
Storage
Relative Humidity
Shock
Type 8161-003-01
Auto-Switching 115/230VAC, 6/3A, 50/60 Hz
0º to 35º C (32º to 95ºF)
-40º to 65º C (-40º to 149º F)
20% - 80% (non-condensing)
10G acceleration peak to peak
5-17Hz, 0.1” double amplitude displacement
17-640Hz, 1.5G acceleration peak to peak
384mm (15.1”) x 482mm (18.9”) x 88mm (3.4”)
Specifications subject to change without notice - 03/2010