ELECTRICAL SOLUTIONS A. System Overview Code Conductor, Heavy Duty, CTAP B1. Cable Ties For Use with Solid and Stranded Copper Code Conductors Type CTAP B2. Cable Accessories B3. Stainless Steel Ties • For tapping into unbroken continuous main, as a wire joint or two-way splice • Wide wire range-taking capability minimizes inventory requirements • Made from heavy wall, extruded, high conductivity copper; provides high strength and premium electrical properties • UL Listed per UL 486 for use up to 35 KV** and temperature rated 90°C when crimped with Panduit and specified competitor crimping tools and dies • UL Listed per UL 467 for grounding and bonding suitable for direct burial in earth or concrete when crimped with Panduit and specified competitor crimping tools and dies^ L W C1. Wiring Duct H C2. Surface Raceway C3. Abrasion Protection C4. Cable Management D1. Terminals D2. Power Connectors D3. Grounding Connectors E1. Labeling Systems Figure Dimensions In. (mm) Copper Conductor Size Part Number CTAP4-8-L AWG Run (mm ) #6 – #4 AWG SOL or STR (16 SOL or STR) CTAP4-6-L #6 AWG STR, #4 AWG SOL or STR (16 SOL or STR) CTAP4-4-L #4 AWG SOL or STR (16 SOL or STR) CTAP2-4-Q #2 AWG SOL or STR (35 SOL or STR) CTAP2-2-X #2 AWG SOL or STR (35 SOL or STR) CTAP2/0-2-X 1/0 – 2/0 AWG STR (70 STR) CTAP2/0-2/0-X 1/0 – 2/0 AWG STR (70 STR) CTAP4/0-2-X 3/0 – 4/0 AWG STR (95 STR) CTAP4/0-2/0-X 3/0 – 4/0 AWG STR (95 STR) CTAP4/0-4/0-X 3/0 – 4/0 AWG STR (95 STR) 2 AWG Tap (mm ) #8 AWG SOL or STR (10 SOL or STR) #6 AWG SOL or STR (95 STR) L 0.46 (11.7) 0.48 (12.2) W 0.63 (16.0) 0.63 (16.0) H 0.73 (18.5) 0.76 (19.3) #4 AWG STR (16 STR) #8 – #4 AWG SOL or STR (10 – 16 SOL or STR) #2 AWG SOL or STR (25 SOL or STR) #8 – #2 AWG SOL or STR (10 – 25 SOL or STR) 1/0 – 2/0 AWG STR (50 STR) #6 – #2 AWG SOL or STR (16 – 35 SOL or STR) 1/0 – 2/0 AWG STR (50 – 70 STR) 3/0 – 4/0 AWG STR (95 STR) 0.46 (11.7) 0.60 (15.2) 0.60 (15.2) 0.80 (20.3) 0.80 (20.3) 0.94 (23.9) 1.00 (25.4) 1.00 (25.4) 0.63 (16.0) 0.76 (19.3) 0.75 (19.0) 0.93 (23.6) 0.93 (23.6) 1.08 (27.4) 1.08 (27.3) 1.08 (27.4) 0.81 (20.6) 0.96 (24.4) 1.05 (26.7) 1.32 (33.5) 1.37 (34.8) 1.66 (42.2) 1.57 (39.9) 1.57 (39.9) 2 Panduit Die Index No.‡ PBG Burndy Die Index No.‡ BG PBG BG PBG BG PC C PC C PO O PO O PD3 F PD3 F PD3 F Wire Strip Length In. (mm) 3/4 (19) 3/4 (19) 3/4 (19) 7/8 (22) 7/8 (22) 1 1/16 (27) 1 1/16 (27) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) Tap Cover* CVR6-1 Std. Pkg. Qty. 50 CVR6-1 50 CVR6-1 50 CVR2-1 25 CVR2-1 10 CVR2-1 10 CVR250-1 10 CVR500-1 10 CVR500-1 10 CVR500-1 10 ‡See page D3.91 for tool and die information. *See page D3.13 for type CVR CTAP covers. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. ^Note: CTAP parts are UL Listed and CSA Certified with AWG wire only. E2. Labels E3. Pre-Printed & Write-On Markers E4. Permanent Identification E5. Lockout/ Tagout & Safety Solutions F. Index Prime items appear in BOLD.