Flex Conductor, Two-Hole, Long Barrel with Window Lug

ELECTRICAL SOLUTIONS
A.
System
Overview
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
Flex Conductor, Two-Hole, Long Barrel with Window Lug, 90° Angle
For Use with Flexible, Extra-Flexible, and Code Stranded Copper Conductors
Type LCCX-F
• Can be used with code conductor and flex conductor class: G, H, I,
K, M and Diesel Locomotive
• Long barrel maximizes number of crimps and provides premium
wire pull-out strength and electrical performance
• Generously beveled wire entry prevents bent back strands when
inserting conductor into barrel
• Color-coded barrels marked with Panduit and specified competitor
die index numbers for proper crimp die selection
C1.
Wiring
Duct
• Inspection window to visually assure full conductor insertion
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated to
90°C when crimped with Panduit and specified competitor
crimping tools and dies
• Meets J-STD-607-A and TIA-942 requirements for network
systems grounding applications
• Available with NEMA hole sizes and spacing
INSPECTION
WINDOW
W
HOLE
SPACING
C2.
Surface
Raceway
T
90˚
B
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
L
Part Number
LCCX8-10AF-L
E1.
Labeling
Systems
0.75
0.41 0.70 0.08 1.65
Red
P21
49
21
3/4
50
1/4
0.63
0.48 0.70 0.07 1.62
Red
P21
49
21
3/4
50
1/4
0.75
0.48 0.70 0.07 1.74
Red
P21
49
21
3/4
50
LCCX8-14DF-L
1/4
1.00
0.48 0.70 0.07 1.99
Red
P21
49
21
3/4
50
LCCX8-38DF-L
3/8
1.00
0.60 0.70 0.05 2.21
Red
P21
49
21
3/4
50
LCCX6-10BF-L
#10
0.75
0.46 1.07 0.08 1.69
Blue
P24
7
24
1 1/8
50
LCCX6-14AF-L
1/4
0.63
0.48 1.07 0.08 1.66
Blue
P24
7
24
1 1/8
50
1/4
0.75
0.48 1.07 0.08 1.78
Blue
P24
7
24
1 1/8
50
1/4
1.00
0.48 1.07 0.08 2.03
Blue
P24
7
24
1 1/8
50
LCCX6-38AF-L
3/8
0.63
0.62 1.07 0.06 1.88
Blue
P24
7
24
1 1/8
50
LCCX6-38CF-L
3/8
0.88
0.62 1.07 0.06 2.13
Blue
P24
7
24
1 1/8
50
LCCX6-38DF-L
3/8
1.00
0.62 1.07 0.06 2.25
Blue
P24
7
24
1 1/8
50
LCCX4-14AF-L
1/4
0.63
0.55 1.05 0.09 1.74
Gray
P29
8
29
1 1/8
50
1/4
0.75
0.55 1.05 0.09 1.87
Gray
P29
8
29
1 1/8
50
3/8
0.75
0.62 1.05 0.08 2.09
Gray
P29
8
29
1 1/8
50
LCCX4-38DF-L
3/8
1.00
0.62 1.05 0.08 2.34
Gray
P29
8
29
1 1/8
50
LCCX2-14AF-E
1/4
0.63
0.70 1.36 0.11 1.94
Brown
P33
10
33
1 7/16
20
1/4
0.75
0.70 1.36 0.11 2.06
Brown
P33
10
33
1 7/16
20
3/8
1.00
0.70 1.36 0.11 2.51
Brown
P33
10
33
1 7/16
20
LCCX2-12F-E
1/2
1.75
0.75 1.36 0.09 3.68
Brown
P33
10
33
1 7/16
20
LCCX1-14AF-X
1/4
0.63
0.76 1.44 0.12 2.08
Green
P37
11
37
1 1/2
10
LCCX1-14BF-X
1/4
0.75
0.76 1.44 0.12 2.20
Green
P37
11
37
1 1/2
10
LCCX6-14DF-L
#8 AWG
#6 AWG
LCCX4-14BF-L
#8 AWG
#8 AWG
#4 AWG
#6 AWG
#5, #4, #3
AWG
#6 AWG
#4 AWG
LCCX2-14BF-E
LCCX2-38DF-E
E3.
Pre-Printed
& Write-On
Markers
#2 AWG
#2 AWG
#2 AWG
LCCX1-14DF-X
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
Burndy T&B
Wire
Panduit Panduit
Die
Die
Strip Std.
Color Die Index Index Index Length Pkg.
No.
No.
(In.)
Code
No.‡
Qty.
Red
P21
49
21
3/4
50
#10
LCCX4-38BF-L
E2.
Labels
Figure Dimensions
Stud
(In.)
Hole
Spacing
(In.)
W
B
T
L
0.63
0.41 0.70 0.08 1.53
LCCX8-14AF-L
LCCX6-14BF-L
D3.
Grounding
Connectors
Stud
Hole
Size
(In.)
#10
LCCX8-10BF-L
LCCX8-14BF-L
D2.
Power
Connectors
Flex Conductor Size
Code
Class G,
Diesel
Conductor
H, I, K, M Locomotive
Size
1/4
1.00
0.76 1.44 0.12 2.45
Green
P37
11
37
1 1/2
10
5/16
0.88
0.76 1.44 0.12 2.38
Green
P37
11
37
1 1/2
10
LCCX1-56DF-X
5/16
1.00
0.76 1.44 0.12 2.51
Green
P37
11
37
1 1/2
10
LCCX1-38DF-X
3/8
1.00
0.76 1.44 0.12 2.58
Green
P37
11
37
1 1/2
10
LCCX1/0-14AF-X
1/4
0.63
0.85 1.50 0.13 2.22
Pink
P42
12
42
1 9/16
10
LCCX1/0-14BF-X
1/4
0.75
0.85 1.50 0.13 2.34
Pink
P42
12
42
1 9/16
10
3/8
1.00
0.85 1.50 0.13 2.66
Pink
P42
12
42
1 9/16
10
1/2
1.75
0.85 1.50 0.13 3.82
Pink
P42
12
42
1 9/16
10
LCCX1-56CF-X
LCCX1/0-38DF-X
LCCX1/0-12F-X
#1 AWG
1/0 AWG
#1 AWG
1/0 AWG
#1 AWG
1/0 AWG
F.
Index
‡See pages D3.70 – D3.73
for tool and die information.
*Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
D2.94
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
Flex Conductor, Two-Hole, Long Barrel with Window Lug, 90° Angle (continued)
Part Number
LCCX2/0-14AF-X
Flex Conductor Size
Code
Conductor
Class G,
Diesel
H, I, K, M Locomotive
Size
LCCX2/0-14BF-X
Stud
Hole
Size
(In.)
1/4
Figure Dimensions
Stud
(In.)
Hole
Spacing
(In.)
W
B
T
L
0.63
0.96 1.50 0.13 2.29
Burndy T&B
Wire
Panduit Panduit
Die
Die
Strip Std.
Color Die Index Index Index Length Pkg.
Code
No.‡
No.
No.
(In.)
Qty.
Black
P45
13
45
1 9/16 10
1/4
0.75
0.96 1.50 0.13 2.42
Black
P45
13
45
1 9/16
10
3/8
1.00
0.96 1.50 0.13 2.73
Black
P45
13
45
1 9/16
10
LCCX2/0-12F-X
1/2
1.75
0.96 1.50 0.13 3.89
Black
P45
13
45
1 9/16
10
LCCX3/0-14BF-X
1/4
0.75
1.06 1.56 0.14 2.50
Orange
P50
14
50
1 5/8
10
LCCX2/0-38DF-X
LCCX3/0-38DF-X
2/0 AWG
2/0 AWG
3/0 AWG
3/0 AWG
2/0 AWG
3/0 AWG
LCCX4/0-14BF-X
LCCX4/0-38DF-X
4/0 AWG
4/0 AWG
4/0 AWG
◆ LCCX4/0-12F-X
LCCX250-14BF-X
LCCX250-38DF-X
250 kcmil
262.6 kcmil
—
LCCX300-38DF-6
LCCX300-12F-6
300 kcmil
313.1 kcmil
—
350 kcmil
373.7 kcmil
—
LCCX350-14BF-6
LCCX350-38DF-6
◆ LCCX350-12F-6
3/8
1.00
1.06 1.56 0.14 2.84
Orange
P50
14
50
1 5/8
10
1/4
0.75
1.19 2.24 0.16 2.69
Purple
P54
15
54
2 5/16
10
3/8
1.00
1.19 2.24 0.16 2.88
Purple
P54
15
54
2 5/16
10
1/2
1.75
1.19 2.24 0.16 4.06
Purple
P54
15
54
2 5/16
10
1/4
0.75
1.28 2.24 0.17 2.46
Yellow
P62
16
62
2 5/16
10
3/8
1.00
1.28 2.24 0.17 2.94
Yellow
P62
16
62
2 5/16
10
3/8
1.00
1.39 2.30 0.18 3.02
Red
P71
18
71H
2 3/8
6
1/2
1.75
1.39 2.30 0.18 3.95
Red
P71
18
71H
2 3/8
6
1/4
0.75
1.54 2.50 0.22 2.65
Blue
P76
19
76H
2 9/16
6
3/8
1.00
1.54 2.50 0.22 3.13
Blue
P76
19
76H
2 9/16
6
1/2
1.75
1.54 2.50 0.22 4.31
Blue
P76
19
76H
2 9/16
6
‡See pages D3.70 – D3.73 for tool and die information.
*Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
◆NEMA hole sizes and spacing.
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
Flex Conductor, Two-Hole, Long Barrel with Window, Narrow
Tongue Lug
D1.
Terminals
For use with Flexible and Extra-Flexible Stranded Copper Copper Conductors
• Inspection window to visually assure full conductor insertion
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated to
90°C when crimped with Panduit and specified competitor
crimping tools and dies
• Meets J-STD-607-A and TIA-942 requirements for network
systems grounding applications
• Available with NEMA hole sizes and spacing
• Narrow tongue width for limited space applications
• Can be used with flex conductor class: G, H, I, K, M and Diesel
Locomotive
• Long barrel maximizes number of crimps and provides premium
wire pull-out strength and electrical performance
• Generously beveled wire entry prevents bent back strands when
inserting conductor into barrel
• Color-coded barrels marked with Panduit and specified competitor
die index numbers for proper crimp die selection
A.
System
Overview
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
W
HOLE
SPACING
E2.
Labels
L
B
INSPECTION
WINDOW
E3.
Pre-Printed
& Write-On
Markers
T
Flex Conductor Size
Diesel
Locomotive
444.4 kcmil
Stud
Hole
Size
(In.)
1/2
Stud
Hole
Spacing
(In.)
1.75
Figure Dimensions
(In.)
Panduit Panduit
Color Die Index
Code
No.‡
Brown
P87
Burndy
Die
Index
No.‡
20
T&B
Die
Index
No.‡
87H
Wire
Strip Std.
Length Pkg.
Qty.
(In.)
2 3/4
6
Part Number
◆ LCCXN450-12-6
Class
G,H, I, K, M
450 kcmil
◆ LCCXN500-12-6
500 kcmil
535.3 kcmil
1/2
1.75
1.30
2.88
0.32
6.71
Pink
P99
L99
99H
2 15/16
6
◆ LCCXN650-12-6
—
646.4 kcmil
1/2
1.75
1.35
2.94
0.36
6.78
Black
P106
24
106
3
6
W
1.19
B
2.69
T
0.33
L
6.41
‡See pages D3.70 – D3.73 for tool and die information.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
◆NEMA hole sizes and spacing.
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
D2.95