PViQ Global Networked Power Outlet Units for Nexus 7.5 Power Supply: PUSP07--WW-ENG

PViQ™ Global Networked Power Outlet Units
for Nexus 7.5 Power Supply
S P E C I F I C AT I O N S H E E T
specifications
PIM
PViQ™ Power Outlet Units shall integrate with the Panduit ®
PIM™ Software Platform to enable intelligent management
of the in-cabinet current usage. This system helps to
quickly identify and resolve issues, find and reclaim
available or underutilized capacity, and automate collection
of real-time and accurate information. The units shall be
Cisco compatible and designed to meet the Nexus 7000
series power requirements. The units shall have local and
remote monitoring for current consumption and easy
upgradable firmware updates and be capable of mounting
vertically to the Net-Access™ and Net-SERV ® Cabinets or
Panduit 4-post rack. The power outlet units shall have
multiple outlet options with standard IEC compliant
receptacles. Power outlet units shall have a black powdercoated finish and include a 3 meter cord using IEC 309
PViQ
QZ1D2P2BN22AD1
Vertical 3~230V, 32A (3) 32A IEC 2P/3W Outlets
Phase (X,Y,Z)
monitoring:
QZ1D2P0BA03AC1
Vertical 3~230V, 32A (6) 32A IEC 2P/3W Outlets
PY
19.0"H x 3.4"W x 9.0"D (483mm x 86mm x 229mm)
66.3"H x 4.75"W x 3.5D (1683mm x 121mm x 89mm)
33"H x 3.50"W x 3.0"D (978mm x 89mm x 76mm)
66.3"H x 4.75"W x 3.0"D (1683mm x 121mm x 76mm)
F
C
All power outlet units include 3 meter power cords, mounting brackets,
screws and tool-less button mounting
O
O
key features and benefits
Web-based GUI provides global network access to real-time
information to improve data center energy efficiency and reduce
operating costs through analysis of current usage and trends
PR
Aggregates information through a single web based GUI to facilitate
easy analysis of data
On unit display provides true RMS input current load (in amps)
for each circuit or phase to properly load balance and maximize
circuits, improving data center management and planning
Alarm messaging capability
Provides user-defined alarm/messaging capabilities for specific
events that exceeded thresholds to help minimize network downtime
Mounting buttons
Allows tool-less mounting of power strips for faster installations
Certification/agency approvals
Complies with IEC 60950-1, EN 55022, EN 55024 and CE Marked
applications
Panduit’s® PViQ™ Networked Power Outlet Units can
either be utilized standalone for smaller installations
or centrally managed by the Physical Infrastructure
Manager™ (PIM™) Software Platform for larger data
centers. The Panduit POUs provide continuous
real-time monitoring via the network for enhanced
system management and reliability.
PZ1D2P0BA03AC1
Phase (X,Y,Z)
monitoring:
Power outlet
unit packaging:
Integrated monitoring
and management
PVQ-C14ADPTR-S
PVQ-C14ADPTR-J
Vertical 3~230V, 320A 16 IEC-13,
4 IEC-19 & (2) 32A IEC 2P/3W Outlets
Horizontal power strips provide up to 3 outlets and mount to any EIA 19"
rack or cabinet. Vertical power strips provide up to 22 outlets and do not
occupy any rack spaces.
Integrates with Panduit ®
PIM ™ Software
C14 Power Cord Adapter
Phase (X,Y,Z)
monitoring:
Power outlet
unit mounting:
Remote access to
current consumption data
™
PIM-BASE
PIM-POWER
Horizontal 3~230V, 32A (3) 32A IEC 2P/3W Outlets
O
PZ1D2P0BA03AC1:
QZ1D2P2BN22AD1:
QZ1D2P0BA03AC1:
QZ1D2P0BA06AE1:
Software Platform and ModulesBase
US:
Japan:
technical information
Dimensions:
™
functionality
module:
Power module:
The Panduit POUs safely and efficiently manage
and distribute power to allow multiple pieces of
equipment to share a single power connector to
enhance scalability of network build outs. Mounting
flexibility allows quick and easy installation and when
used with Panduit Net-Access™ and Net-SERV®
Cabinets the user receives a complete networking
solution that will satisfy data center requirements
today and into the future.
Phase (X,Y,Z)
monitoring:
QZ1D2P0BA06AE1
Net-Access ™ 7018 Cabinets for Use in
Hot Aisle/Cold Aisle Applications
45 RU, no doors, no side
panels, 7018 inlet, and
exhaust ducting:
CN3847018NU
45 RU, perforated split doors,
no side panels, 7018
inlet, and exhaust ducting: CN5847018NU
45 RU, perforated split
doors, side panels, 7018
inlet, and exhaust ducting: CN4847018NU
42 RU, perforated split doors,
side panels, 7018
inlet, and exhaust ducting: CN48470182NU
45 RU, perforated split doors,
no side panels, 7018
inlet, exhaust ducting,
and cage nut rails:
CN5847018CNNU
Net-Access ™ 7018 Cabinets for Use in
Cold Aisle Containment Applications
45 RU, perforated split
doors, side panels,
vertical blanking panels,
7018 inlet ducting:
CN484C7018NU
42 RU, perforated split
doors, side panels, vertical
blanking panels,
7018 inlet ducting, and
cage nut rails:
CN484C70182CNNU
™
Net-Access 7018 Cabinet for Use
with Vertical Exhaust Duct Applications
45 RU, front perforated
split door, rear solid split
door, no side panels,
vertical blanking panels,
7018 inlet ducting:
CN584H7018
7018 vertical exhaust
ducting height adjustable
from 21" to 45"
(534mm to 1143mm):
CVED40VEN
7018 vertical exhaust
ducting height adjustable
from 42" to 70"
(1067mm to 1778mm):
CVED40VE
Power Cord C13 — C14 end:
PC14C13BL1.5
PC14C13BL2
PC14C13BL3
Power Cord Retainers
C13
C13
C19
C19
for
for
for
for
2.00"
2.25"
2.00"
2.25"
POU
POU
POU
POU
Body
Body
Body
Body
PRPC13W-2.0-X
PRPC13W-2.25-X
PRPC19Y-2.0-X
PRPC19Y-2.25-X
For additional power cord information, refer to
Power Outlet Unit Power Cords Spec Sheet,
WASP27--WW-ENG.
w w w. pa n d u it.c o m
PViQ™ Global Networked Power Outlet Units for Nexus 7.5 Power Supply
2
1
F
C
O
PY
3
Network Connection
2
Integrated power 4 digit LED
PR
O
O
1
• RJ45 connections for remote monitoring
• Displays true RMS current
• Provides real-time current consumption at the power
strip, for improved manageability and network reliability
• Scrolls through the most recent current measurement
(in amps) for each circuit, one at a time
3
Pause scroll/IP reset button
• Pause the display on the current measurement, to read
circuit name and current reading
• View the currently configured IP address on the unit or
reset the IP address to the default
PViQ™ Global Networked Power Outlet Units for Nexus 7.5 Power Supply
Current Monitoring
• Provides real time current
information via a standard
web browser
Display
Alarms
PR
O
O
• Alarm status provided if current
is greater than entered threshold
F
C
O
PY
• Name and location information
can be stored for easy
identication of POU and
individual outlets
Configuration
• Name and location
information can be stored for
easy indentification of POU
and individual outlets
• Simple network configuration
for easy setup
PViQ™ Global Networked Power Outlet Units for Nexus 7.5 Power Supply
Front
Back
C
O
PY
PZ1D2P0BA03AC1
PR
O
O
F
QZ1D2P0BA03AC1
QZ1D2P2BN22AD1
QZ1D2P0BA06AE1
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario
[email protected]
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
[email protected]
Phone: 44.20.8601.7200
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
[email protected]
Phone: 65.6305.7575
PANDUIT JAPAN
Tokyo, Japan
[email protected]
Phone: 81.3.6863.6000
PANDUIT LATIN AMERICA
Guadalajara, Mexico
[email protected]
Phone: 52.33.3777.6000
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
[email protected]
Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
Visit us at www.panduit.com
Contact Customer Service by email: [email protected]
or by phone: 800.777.3300
©2012 Panduit Corp.
ALL RIGHTS RESERVED.
PUSPXX--WW-ENG
12/2012