Wirewound Resistors, Flameproof, Bath-tub Type Wirewound Resistors, Flameproof, Bath-tub Type Type: ERF Discontinued Axial leads type ERFA Radial insertion type ERFT(L) Off PC board type ERFZX ERFZY ERFZ ■ Features ● ● ● ● ● Flameproof Exclusive surge characteristics Uniform quality Reference standards to IEC 60115-4, EIAJ RC-2123A RoHS compliant ■ Explanation of Part Numbers 1 2 3 4 5 6 7 8 9 10 11 & 3 ' ; : , 3 Product Code Fixed Wirewound Resistor Bath-tub Power Rating Code Rated power 2 2W 3 3W 5 5W 7 7W 10 10 W 5 7 10 15 20 Style of Terminal with Fixture Style Code Axial leads A T (L) Radial insertion (Low resistance) Short terminal ZX Long terminal ZY Long terminal (Dual nail) Z 5W 7W 10 W 15 W 20 W Resistance Tolerance Code Tol. J ±5 % K ±10 % Standard Resistance Tolerance 10 ? : J <10 ?: K 12 Suffix for Special Features or Packing Code Nil. Std. Packing Resistance Value The first two digits are significant figures of resistance and the third one denotes number of zeros following. Decimal point is expressed by R as 4.7 = 4R7 ■ Construction Flameproo ceramic case Flame proof & Insulation cement Marking Automatically clamped termination and lead welding Resistance wire Nickel-Chromium or Copper-Nickel alloy resistance wire Lead wire Fiber-Glass core Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 Aug. 2012 61 Wirewound Resistors, Flameproof, Bath-tub Type Discontinued Power Rating at 70 °C (W) Type Power Derating Curve For resistors operated in ambient temperatures above 70 °C, power rating shall be derated in accordance with the figure below. Dielectric Withstanding Standard Quantity Voltage (pcs.) (VAC) Resistance Range (Ω) min. max. ERF2A 2 0.1 390 1000 1000 ERF3A 3 0.18 680 1000 1000 ERF5A 5 0.18 680 1000 1000 ERF7A 7 0.22 1.5 k 1000 500 ERF10A 10 0.33 2.4 k 1000 500 120 Rated Load (%) ERFA (Axial Lead Type) ■ Ratings 100 –55 °C 70 °C 80 60 40 275 °C 20 0 –60 –40 –20 0 155 °C max. 20 40 60 80 100 120 140 160 180 200 220 240 260 Ambient Temperature (°C) ■ Dimensions in mm (not to scale) W±1.0 H±1.0 d±0.1 Mass (Weight) [g/pc.] ERF2A 18.0±1.0 6.4 6.4 0.8 2 ERF3A 22.0±1.0 8.0 8.0 0.8 4 ERF5A 22.0±1.0 9.5 9.0 0.8 5 ERF7A 35.0±1.5 9.5 9.0 0.8 8 ERF10A 48.0±2.0 9.5 9.0 0.8 12 fd H 35.0±3.0 Dimensions (mm) L Type (Marking) L 35.0±3.0 Lead Forming W W Recommended PWB hole Type L±1 ERF2A...P 18 6.4 6.4 25 1.4 f1.00±0.05 ERF3A...H 22 8.0 8.0 27.5 1.4 ERF5A...H 22 9.0 9.5 27.5 1.4 10 W±1.0 H±1.0 W±0.2 h1±2 P±2 h2±1 h3±1 6 4 13.2 10 4 18 4 18.75 h3 L h2 h1 H P f0.8±0.1 3.0 max. W Power Derating Curve Radial Inser tion Type ■ Ratings Resistance Range (Ω) min. max. 120 Dielectric Withstanding Standard Quantity Voltage (pcs.) (VAC) ERF2T(L) 2 (0.01) 0.1 (0.082) 390 1000 500 ERF3T(L) 3 (0.01) 0.18 (0.082) 680 1000 500 ERF5T(L) 5 (0.01) 0.18 (0.082) 680 1000 500 ERF7T(L) 7 (0.01) 0.22 (0.1) 1.5 k 1000 500 ERF10T(L) 10 (0.01) 0.33 (0.1) 2 k 1000 500 Rated Load (%) Type Power Rating at 70 °C (W) 100 –55 °C 70 °C 80 60 40 275 °C 20 0 –60 –40 –20 0 155 °C max. 20 40 60 80 100 120 140 160 180 200 220 240 260 Ambient Temperature (°C) ● TL (2TL to 10TL) are series of low resistance value. ■ Dimensions in mm (not to scale) D Type L H W 0d Dimensions (mm) W D H L P 0d Mass (Weight) [g/pc.] ERF2T(L) 11.0±1.0 7.0±1.0 20.5±1.5 4.5 –1.0 +2.0 5.0 –1.0 +2.0 0.8±0.1 3.9 ERF3T(L) 12.0±1.0 8.0±1.0 25.0±1.5 4.5 –1.0 +2.0 5.0 –1.0 +2.0 0.8±0.1 5.5 ERF5T(L) 13.0±1.0 9.0±1.0 25.5±1.5 4.5 –1.0 +2.0 5.0 –1.0 +2.0 0.8±0.1 6.7 ERF7T(L) 16.0±1.0 9.0±1.0 29.0±1.5 +2.0 –1.0 4.5 +2.0 –1.0 7.5 0.8±0.1 (1.0±0.1) 8.8 ERF10T(L) 16.0±1.0 9.0±1.0 34.0±1.5 4.5 –1.0 +2.0 7.5 –1.0 0.8±0.1 (1.0±0.1) 10.7 P +2.0 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 Aug. 2012 62 Wirewound Resistors, Flameproof, Bath-tub Type ERFZ (Off PC Board Type) ■ Ratings Discontinued max. Dielectric Withstanding Voltage (VAC) Standard Quantity pcs. 0.22 820 1000 500 0.39 1.5k 1000 500 Resistance Range (Ω) Power Rating (W) min. ERF5Z X Y 5 ERF7Z X Y 7 ERF10Z X Y 10 0.39 2.2k 1000 500 ERF15Z X Y 15 0.51 2.2k 1000 500 ERF20Z X Y 120 20 0.51 2.4k 1000 –55 °C 100 Rated Load (%) Type Power Derating Curve For resistors operating in ambient temperatures above 70 °C (25 °C) power rating shall be derated in accordance with the figure below. 25 °C 70 °C 5, 7,10Z, ZX, ZY 80 15, 20Z, ZX, ZY 60 40 20 0 –60 –40 –20 500 155 °C max. 0 20 40 60 275 °C 80 100 120 140 160 180 200 220 240 260 Ambient Temperature (°C) ■ Dimensions in mm (not to scale) (Z) W ( ZX, ZY ) W (H1) H4 (t) H3 H3 (H1) H2 H2 ( Z, ZX, ZY ) T2 T3 L Type ERF5Z ERF7Z H4 P T1 T2 T4 T1 T3 Dimensions (mm) L P±1.5 W±1.0 (H1) H2±1.0 +2 H3 H4±0.5 T1±0.3 T2±0.2 T3±0.2 T4 (t) Mass (Weight) [g/pc.] 6 X 27.0±1.0 15.0 9.5 24 9.5 10 4.5 7.3 1.6 1.4 — 0.5 Y 27.0±1.0 15.0 9.5 39 9.5 25 4.5 7.3 1.6 1.4 — 0.5 7 27.0±1.0 (15.0) 9.5 36 9.5 22 4.5 7.3 1.5 1.0 3.5 0.5 6.9 X 35.0±1.0 22.5 9.5 24 9.5 10 4.5 7.3 1.6 1.4 — 0.5 7.6 Y 35.0±1.0 22.5 9.5 39 9.5 25 4.5 7.3 1.6 1.4 — 0.5 8.6 35.0±1.0 (22.5) 9.5 36 9.5 22 4.5 7.3 1.5 1.0 3.5 0.5 8.5 (1) (2) X 48.0±1.5 35.0 9.5 24 9.5 10 4.5 7.3 1.6 1.4 — 0.5 10 ERF10Z Y 48.0±1.5 35.0 9.5 39 9.5 25 4.5 7.3 1.6 1.4 — 0.5 10.8 (3) 48.0±1.5 (35.0) 9.5 36 9.5 22 4.5 7.3 1.5 1.0 3.5 0.5 10.6 X 48.0±1.5 32.5 12.5 32.5 12.5 15 5.0 10.0 3.0 2.7 — 0.5 17 ERF15Z Y 48.0±1.5 32.5 12.5 47.5 12.5 30 5.0 10.0 3.0 2.7 — 0.5 20 48.0±1.5 (32.5) 12.5 47.5 12.5 30 5.0 10.0 2.0 1.5 5 0.5 19.2 X 63.5±1.5 47.5 12.5 32.5 12.5 15 5.0 10.0 3.0 2.7 — 0.5 23.5 ERF20Z Y 63.5±1.5 47.5 12.5 47.5 12.5 30 5.0 10.0 3.0 2.7 — 0.5 26.5 30 5.0 10.0 2.0 1.5 5 0.5 25.7 (4) (5) 12.5 47.5 12.5 63.5±1.5 (47.5) Note: (1) to (3); Tolerance +2 to +6, (4) to (5); Tolerance 0 to +4. Recommended PWB Hole Dimensions (mm) Power Rating (W) 2–0.8L2 R0.2 P Z 15 R0.2 3.5 5 ZX · ZY 22.5 2 7 P P 10 2–1.0L3.5 R0.2 2.5 20 R0.2 5 15 35 1 P P 32.5 47.5 1.2 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 Aug. 2012 63 Wirewound Resistors, Flameproof, Bath-tub Type ■ Temperature Rising Data Discontinued Axial Leads Type (Hot Spot Temperature) Radial Insertion Type (Hot Spot Temperature) (Terminal Temperature of PC Board Conjunction Point) measurement position (M.P) 200 5A 3A 2A 100 0 50 100 Percent of Rated Load (%) (t=1.6 mm) P.C.B 1.6t Phenolic 7T 3T 50 0 measurement (t=1.6 mm) position (M.P) P.C.B 1.6t Phenolic 10T 5T 7T 100 2T 3T 50 0 100 50 Percent of Rated Load (%) 2T 100 50 Percent of Rated Load (%) (Terminal Temperature of PC Board Conjunction Point) 150 20Z 15Z 10Z 7Z measurement position (M.P) 5Z Temperature Rise 6T (°C) Temperature Rise 6T (°C) 10T 100 Off PC Board Type (Hot Spot Temperature) 300 Temperature Rise 6T (°C) 10A 7A 150 5T 200 100 0 50 100 150 200 Percent of Rated Load (%) 100 m po eas sit ure ion m (M ent .P) 300 Temperature Rise 6T (°C) Temperature Rise 6T (°C) 150 measurement position (M.P) (t=1.6 mm) P.C.B 1.6t Phenolic 20ZX 15ZX 10ZX 20ZY 7ZX 5ZX 15ZY 10ZY 7ZY 5ZY 50 0 50 100 150 200 Percent of Rated Load (%) ■ Packaging Methods Please contact the factory for packaging methods Safety Precautions The following are precautions for individual products. Please also refer to the common precautions for Fixed Resistors shown on this catalog. 1. Since Wirewound Resistors (hereafter called the resistors) generate heat during use, mount them on your product and carefully check the effect of heat on other components. Provide for adequate safety when designing your product. Otherwise, when a short circuit or other abnormality occurs, or when a voltage or current exceeding the rating is applied, the resistors may overheat without breaking, or may generate smoke or red-heat, breaking the ceramic case and thus exposing the red-heating resistor element. 2. Carefully check the inductance effect of the resistors when using them in a high-frequency circuit. 3. If a transient load (heavy load in a short time) like a pulse is expected to be applied, check and evaluate the operations of the resistors when installed in your products under the most adverse conditions before use. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 01 Aug. 2012 64