RoHS-Non-HF Test Report

Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Page 1 of 19
Applicant:
Zhejiang Rectron Electronic Co.,Ltd
Address:
28# Lizheng Road,Jia Shan Economic Development Zone,Zhe
Jiang,China
The following sample(s) was/were submitted and identified on behalf of the client as:
Sample Name:
Please refer to next page(s)
Manufacturer:
RECTRON
Applies to the following packages: SMA(L) /SMB(L) /SMC(L) / SMX /SlimPAQ (P) /ThinPAQ /
SOD123 / SOD123F(L) / MELF / MINI MELF / R1 / A405 /
DO41 / DO15 / R3 / R6 / R7 / 1.5KE / DO201 / DO204 /
HVM / HVP / DBS / DB / DBLS / SLDBS / MDS / MD /
BDB / RS1 / RS2(L) / RS4L / RS6 / RS8 / RB15 / WOM /
RC2 / BR3 / BR6 / BR8 / BR10 / BR15(W)-25(W)-35(W) /
MB15(W)-25(W)-35(W) / MP15(W)-25(W)-35(W) /
RS1M-2M-4M-6M-8M-10M-15M-20M-25M-35M /
RBU4M-6M-8M-10M-15M / (I)TO220A / (I)TO220 /DPAK /
D2PAK / TO247 / SOT23/SMAF/MDSJ/LMDS/SOD323/MB
Sample Received Date: 2015.06.12
Test Period:
2015.06.12 To 2015.06.30
Reference Method:
(1) IEC 62321-5 Edition 1.0:2013 method, Lead Analysis is performed by AAS
(2) IEC 62321-5 Edition 1.0:2013 method, Cadmium Analysis is performed by AAS
(3) IEC 62321-4 Edition 1.0:2013 method,
Mercury Analysis is performed by ICP-OES
(4) IEC 62321 Edition 1.0:2008 method, Hexavalent Chromium Analysis is
performed by UV-Vis/Hexavalent Chromium Analysis is performed By
Spot-test/Boiling-water- extraction Method
(5) IEC 62321 Edition 1.0:2008 method,
PBBs and PBDEs Analysis is performed by GC-MS
(6) EN 14582:2007 method, F, Cl, Br, I Analysis is performed by IC
(7) EPA8061A:1996 method, Phthalate Analysis is performed by GC-MS
(8) EPA8270D:2007 method,HBCDD Analysis is performed by GC-MS
(9) EPA 3540C:1996 method,PFOS,PFOA Analysis is performed by LC-MS/MS
(10) ZLS,ZEK 01.4-08 method:PAHs Analysis is performed by GC-MS
(11) ICP General Rule JY/T015-1996 and EPA6010C:2007 method,
P、Sb Analysis is performed by ICP-OES
(12) ISO17070:2006 method,TBBP-A Analysis is performed by GC-MS
(13) DBT、TPHT、TBT、DOT Analysis is performed by GC-MS
Test Result:
Please refer to next page(s)
Approved by:
Code: un3tq7vdn
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Test Result (Unit:mg/kg)
NO.:A71801704
Test Item
Lead (Pb)
Cadmium (Cd)
Mercury (Hg)
Hexavalent Chromium (Cr6+)
Sum of PBBs
Bromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Sum of PBDEs
Bromodiphenyl ether
Dibromodiphenyl ether
Tribromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Octabromodiphenyl ether
Nonabromodiphenyl ether
Decabromodiphenyl ether
Date:2015.06.30
Sample Name:Molding
MDL
Test Result
1
N.D.
1
N.D.
1
N.D.
1
N.D.
—
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
—
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
Page 2 of 19
RoHS Limit
1000
100
1000
1000
1000
—
—
—
—
—
—
—
—
—
—
1000
—
—
—
—
—
—
—
—
—
—
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Test Result (Unit:mg/kg)
NO.:A71803704
Test Item
Lead (Pb)
Cadmium (Cd)
Mercury (Hg)
Hexavalent Chromium (Cr6+)
Sum of PBBs
Bromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Sum of PBDEs
Bromodiphenyl ether
Dibromodiphenyl ether
Tribromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Octabromodiphenyl ether
Nonabromodiphenyl ether
Decabromodiphenyl ether
Date:2015.06.30
Sample Name:Silicon Rubber
MDL
Test Result
1
N.D.
1
N.D.
1
N.D.
1
N.D.
—
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
—
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
Page 3 of 19
RoHS Limit
1000
100
1000
1000
1000
—
—
—
—
—
—
—
—
—
—
1000
—
—
—
—
—
—
—
—
—
—
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Test Result (Unit:mg/kg)
NO.:A71804704
Test Item
Lead (Pb)
Cadmium (Cd)
Mercury (Hg)
Hexavalent Chromium (Cr6+)
Sum of PBBs
Bromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Sum of PBDEs
Bromodiphenyl ether
Dibromodiphenyl ether
Tribromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Octabromodiphenyl ether
Nonabromodiphenyl ether
Decabromodiphenyl ether
Date:2015.06.30
Sample Name:Uv Ink
MDL
Test Result
1
N.D.
1
N.D.
1
N.D.
1
N.D.
—
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
—
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
5
N.D.
Page 4 of 19
RoHS Limit
1000
100
1000
1000
1000
—
—
—
—
—
—
—
—
—
—
1000
—
—
—
—
—
—
—
—
—
—
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Test Result (Unit:mg/kg)
NO.:A71801704
Date:2015.06.30
Page 5 of 19
Sample Name:Molding
Test Item
Test Result
Naphthalene
Not Detected(<0.2)
Acenaphthylene
Not Detected(<0.2)
Acenaphthene
Not Detected(<0.2)
Fluorene
Not Detected(<0.2)
Phenanthrene
Not Detected(<0.2)
Anthracene
Not Detected(<0.2)
Fluoranthene
Not Detected(<0.2)
Pyrene
Not Detected(<0.2)
Benzo(a)Anthracene
Not Detected(<0.2)
Chrysene
Not Detected(<0.2)
Benzo(b)Fluoranthene
Not Detected(<0.2)
Benzo(k)Fluoranthene
Not Detected(<0.2)
Benzo(e)Pyrene
Not Detected(<0.2)
Benzo(j)Fluoranthene
Not Detected(<0.2)
Benzo(a)Pyrene
Not Detected(<0.2)
Indeno(1,2,3-cd) Pyrene
Not Detected(<0.2)
Dibenzo(a,h)Anthracene
Not Detected(<0.2)
Benzo(g,h,i)Perylene
Not Detected(<0.2)
PAHs
Sum PAHs
Not Detected(<0.2)
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Test Result (Unit:mg/kg)
NO.:A71803704
Date:2015.06.30
Page 6 of 19
Sample Name:Silicon Rubber
Test Item
Test Result
Naphthalene
Not Detected(<0.2)
Acenaphthylene
Not Detected(<0.2)
Acenaphthene
Not Detected(<0.2)
Fluorene
Not Detected(<0.2)
Phenanthrene
Not Detected(<0.2)
Anthracene
Not Detected(<0.2)
Fluoranthene
Not Detected(<0.2)
Pyrene
Not Detected(<0.2)
Benzo(a)Anthracene
Not Detected(<0.2)
Chrysene
Not Detected(<0.2)
Benzo(b)Fluoranthene
Not Detected(<0.2)
Benzo(k)Fluoranthene
Not Detected(<0.2)
Benzo(e)Pyrene
Not Detected(<0.2)
Benzo(j)Fluoranthene
Not Detected(<0.2)
Benzo(a)Pyrene
Not Detected(<0.2)
Indeno(1,2,3-cd) Pyrene
Not Detected(<0.2)
Dibenzo(a,h)Anthracene
Not Detected(<0.2)
Benzo(g,h,i)Perylene
Not Detected(<0.2)
PAHs
Sum PAHs
Not Detected(<0.2)
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Test Result (Unit:mg/kg)
NO.:A71801704
Sample Name:Molding
Test Item
Test Result
HBCDD
Not Detected(<5)
DBP
Not Detected(<50)
BBP
Not Detected(<50)
DEHP
Not Detected(<50)
DIBP
Not Detected(<50)
DNOP
Not Detected(<50)
DINP
Not Detected(<50)
DIDP
Not Detected(<50)
P
120
Sb
8.06×103
Test Result (Unit:mg/kg)
NO.:A71801704
Test Item
F
Cl
Br
I
PFOS
PFOA
TBBP-A
DBT
TPHT
TBT
DOT
Sample Name:Molding
MDL
50
50
50
50
2
2
10
0.2
0.2
0.2
0.2
Page 7 of 19
Test Result
N.D.
104
4.30×103
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Test Result (Unit:mg/kg)
NO.:A71803704
Date:2015.06.30
Page 8 of 19
Sample Name:Silicon Rubber
Test Item
Test Result
HBCDD
Not Detected(<5)
DBP
Not Detected(<50)
BBP
Not Detected(<50)
DEHP
Not Detected(<50)
DIBP
Not Detected(<50)
DNOP
Not Detected(<50)
DINP
Not Detected(<50)
DIDP
Not Detected(<50)
P
6
Sb
Not Detected(<1)
Test Result (Unit:mg/kg)
NO.:A71803704
Test Item
F
Cl
Br
I
PFOS
PFOA
TBBP-A
DBT
TPHT
TBT
DOT
Sample Name:Silicon Rubber
MDL
Test Result
50
N.D.
50
N.D.
50
N.D.
50
N.D.
2
N.D.
2
N.D.
10
N.D.
0.2
N.D.
0.2
N.D.
0.2
N.D.
0.2
N.D.
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Test Result (Unit:mg/kg)
NO.:A71804704
Date:2015.06.30
Page 9 of 19
Sample Name:Uv Ink
Test Item
Test Result
HBCDD
Not Detected(<5)
DBP
Not Detected(<50)
BBP
Not Detected(<50)
DEHP
Not Detected(<50)
DIBP
Not Detected(<50)
Test Result (Unit:mg/kg)
NO.:A71804704
Test Item
F
Cl
Br
I
TBBP-A
DBT
TPHT
TBT
Sample Name:Uv Ink
MDL
50
50
50
50
10
0.2
0.2
0.2
Test Result
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Test Results (Unit:mg/kg)
NO.:A71797704
Sample Name:Lead Wire
Test Item
MDL
Lead (Pb)
RoHS Limit
1
Test Result
N.D.
Cadmium (Cd)
1
N.D.
100
Mercury (Hg)
1
N.D.
1000
Hexavalent Chromium (Cr6+)
NO.:A71798704
Test Item
See Note (6)
Negative
Sample Name:Solder Wafer
MDL
Test Result
9.73×10
1000
—
RoHS Limit
5*
Lead (Pb)
1
Cadmium (Cd)
1
N.D.
100
Mercury (Hg)
1
N.D.
1000
6+
Hexavalent Chromium (Cr )
NO.:A71799704
Test Item
Lead (Pb)
Cadmium (Cd)
Mercury (Hg)
6+
Hexavalent Chromium (Cr )
NO.:A71800704
Test Item
Lead (Pb)
Cadmium (Cd)
Mercury (Hg)
6+
Hexavalent Chromium (Cr )
Note:
Page 10 of 19
See Note (6)
Negative
Sample Name:Dice Wafer
MDL
Test Result
N.D.
1
1000
—
RoHS Limit
1000
1
N.D.
100
1
N.D.
1000
1
N.D.
Sample Name:Plating
MDL
Test Result
46
1
N.D.
1
1000
RoHS Limit
1000
100
1
N.D.
1000
See Note (6)
Negative
—
(1) mg/kg = ppm
(2) “—” = Does not stipulate
(3) N.D. = Not Detected (<MDL)
(4) MDL = Method Detection Limit
(5) The most allowable limit value reference to RoHS Directive 2011/65/EU Annex Ⅱ
(6) Spot-test:
Negative = Not Detected of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result cannot be
confirmed or negative)
Boiling-water-extraction:
Negative = Not Detected of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal
or greater than 0.02 mg/kg with 50cm2 sample surface area used.
Storage conditions and production date of the tested sample are unavailable and thus results of CrVI represent
status of the sample at the time of testing.
(7) *:According to applicant’s declaration,samples comply with exempted Items of RoHS Directive, “7(a)Lead in
high melting temperature type solders (i.e. lead- based alloys containing 85 % by weight or more lead).”
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Page 11 of 19
Sample No. & Photo:
Pony authenticate the photo on original report only
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Measurement Flow-chart
Page 12 of 19
Tested by:Zhao Ting
Checked by:Cao Jia
Person in charge of the lab:Zhang Daiqin
These Samples Were Dissolved Totally By Pre-conditioning Method According To Below Flow Chart. (Cr6+
And PBBs/PBDEs Test Method Excluded)
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/hotplate
Sample solvent
extraction
Filtration
Concentration/
Dilution
Solution
Cr6+
PBBs/PBDEs
Residue
Nonmetallic
material
Negative
Adding
extraction
solution
Filtration
dissolved totally
Heating to
90-95℃ for
extraction
GC-MS
Filtration and
AAS/ICP-OES
Metallic
material
pH
Spot test
Boiling
water
Filtration
and pH
Positive
Adding 1,5diphenylcarbazi
de for color
development
DATA
UV-Vis
DATA
DATA
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Halogen measurement flow-chart
Tested by: Zhang Tianyu
Checked by:Cao Jia
Person in charge of the lab:Zhang Daiqin
Page 13 of 19
Sample preparation
Weighing sample
Oxygen bomb method preparation
IC analysis
Data
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Phthalate Measurement Flow-chart
Page 14 of 19
Tested by:Jin Ling
Checked by:Cao Jia
Person in charge of the lab:Zhang Daiqin
Sample preparation
Weighing samples
Extraction in organic solvent
Concentration / Dilution of extraction solution
GC/MS analysis
data
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
HBCDD Flow Chart
Page 15 of 19
Tested by:Zhao Haiyun
Checked by:Cao Jia
Person in charge of the lab:Zhang Daiqin
Sample preparation
Weighing samples
Extraction in organic solvent
Concentration / Dilution of extraction solution
GC/MS analysis
data
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
PFOS,PFOA Measurement Flow-chart
Page 16 of 19
Tested by:Zhou Liguang
Checked by:Cao Jia
Person in charge of the lab:Zhang Daiqin
Sample preparation
Weighing samples
Extraction in organic solvent
Cleanup and concentration
LC-MS/MS analysis
data
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Page 17 of 19
PAHs Measurement Flow-chart
Tested by:Jin Ling
Checked by:Cao Jia
Person in charge of the lab:Zhang Daiqin
Sample preparation
Weighing samples
Extraction in organic solvent
Concentration / Dilution of extraction
GC/MS analysis
data
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
Element Measurement Flow-chart
Page 18 of 19
Tested by:Fu Hao
Checked by:Cao Jia
Person in charge of the lab:Zhang Daiqin
Sample Preparation
Weigh and prepare sample according to the request.
Sample Pre-condition
Digest the samples completly with appropriate mix acid at
appropriate condition, Filter the solution into a flask and make
up to mark.
Sample Analyse
Analysis elements content in the sample solution with
ICP-OES.
Result
Calculate the instrument reading and give the final result.
The page below is blank。
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127
Test Report
NO.:BZC2VFWAA71807744
Date:2015.06.30
TBBP-A Flow Chart
Page 19 of 19
Tested by:Huang Wenjun
Checked by:Cao Jia
Person in charge of the lab:Zhang Daiqin
Sample preparation
measure
Sample extraction of
organics ultrasonic
GC/MS analysis
data
***End of Report***
www. ponytest. com
Hotline 400-819-5688
BeijingLab:(010)82618116
ChangchunLab:(0431)85150908
ShanghaiLab:(021)64851999
ShenzhenLab:(0755)26050909
QingdaoLab:(0532)88706866
DalianLab:(0411)84650820
NingboLab:(0574)87736499
GuangzhouLab:(020)89224310
TianjinLab:(022)27360730
ZhengzhouLab:(0371)69350670
HangzhouLab:(0571)87219096
WuhanLab:(027)83997127