bat54aw.pdf

RECTRON
BAT54AW
SEMICONDUCTOR
TECHNICAL SPECIFICATION
SOT-323 SURFACE MOUNT SCHOTTKY
BARRIER DIODE
FEATURES
* Low forward voltage drop
* Fast switching
* Uitra - small surface mount package
* PN Junction guard ring for transient and ESD protection
Marking: KL6
SOT-323
0.053(1.35)
0.045(1.15)
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: UL 94V-O rate flame retardant
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.006 gram
0.006(0.15)
0.003(0.08)
0.043(1.10)
0.035(0.90)
REF 0.021(0.53)
0.016(0.40)
0.004(0.10)
0.000(0.00)
0.096(2.45)
0.085(2.15)
0.008(0.20)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
0.055(1.40)
0.047(1.20)
0.087(2.20)
0.079(2.00)
Ratings at 25 o C ambient temperature unless otherwise specified.
Dimensions in inches and (millimeters)
o
MAXIMUM RATINGS ( @ TA = 25 C unless otherwise noted )
SYMBOL
VALUE
Peak repetitive reverse voltage
CHARACTERISTICS
VRRM
30
working peak reverse voltage
VRWM
30
VR
30
DC blocking voltage
IF
200
µA
300
µA
IFSM
600
µA
PD
200
µW
RθJA
625
Κ/Ω
Tj, Tstg
-65~+125
Repetitive peak forward current (Note 1)
@ t < 1.0 s
Power dissipation (Note 1)
Thermal resistance, Junction to ambient air (Note 1)
Operating and storage temperature range
V
IFRM
Forward contiunous current (Note 1)
Forward surge current (Note 1)
UNITS
o
C
o
ELECTRICAL CHARACTERISTICS ( @ TA = 25 C unless otherwise noted )
SYMBOL
MIN
TYP
MAX
UNITS
V(BR)R
30
-
-
V
(IF= 0.1mA)
-
-
240
(IF= 1mA)
-
-
320
(IF= 10mA)
-
-
400
(IF= 30mA)
-
-
500
(IF= 100mA)
-
-
1000
IR
-
-
2.0
µA
Junction capacitance (VR= 1.0V, f= 1.0MHz)
Cj
-
-
10
PF
Reveres recovery time (IF=10mA through IR=10mA to IR=1.0mA,RL=100Ω)
trr
-
-
5.0
CHARACTERISTICS
Reveres breakdown voltage (IRS= 100µA)
Forward voltage (Note 2)
Reverse leakage current (VR= 25V) (Note 2)
Notes: 1. Valid provided that terminals are kept at ambient temperature.
2. tp <300µs, duty cycle <2%.
DS30065 Rev. 2P-1
VF
mV
ns
2006-3
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
RECTRON