LCP Series - Miniature Low Cost Inductors

LCP Series • Miniature Low Cost Toroidal Inductors
LCP Series surface mount toroidal inductors are designed for
use in applications where energy storage is required for
maintenance of a highly stable inductance when a rapid change
in load current occurs. These inductors are excellent for filtering
high frequency signals while supporting a substantial DC
current as well as for AC ripple, switch mode power supplies
and for use with DC-DC Converters.
Features
• Operating frequency to 1 MHz
• High energy storage with minimum saturation
• High stability from no load to full load
• Designed as 1:1 Coupled Inductor (Series or Parallel)
or as 1:1 Isolation Transformer
• Manufactured in ISO-9001:2000, TS-16949:2002
and ISO-14001:2004 certified Talema facility
• Meets lead free reflow level J-STD-020C
• Fully RoHS compliant
Applications
DC-DC Converters • Common Mode Filter • Computer Note Books
Pulse Modulation Switching Regulators: Step-up, Step-down,
Inverting or dual output • Filtering Battery Powered Equipment
Parallel Connected
Series Connected
(ADC)
L0 (µH)
±15%
N o L o ad
LCP1-3.00-2.2
LCP1-2.10-4.7
LCP1-1.40-10
LCP1-1.10-15
LCP1-0.92-22
LCP1-0.76-33
LCP1-0.64-47
LCP1-0.54-68
LCP1-0.44-100
LCP1-0.36-150
LCP1-0.30-220
LCP2-4.40-2.2
LCP2-3.10-4.7
LCP2-2.08-10
LCP2-1.68-15
LCP2-1.40-22
LCP2-1.32-33
LCP2-1.08-47
LCP2-0.80-68
LCP2-0.66-100
LCP2-0.54-150
3.00
2.10
1.40
1.10
0.92
0.76
0.64
0.54
0.44
0.36
0.30
4.40
3.10
2.08
1.68
1.40
1.32
1.08
0.80
0.66
0.54
2.2
4.7
10
15
22
33
47
68
100
150
220
2.2
4.7
10
15
22
33
47
68
100
150
9
16
37
58
86
133
205
307
376
719
866
7
13
28
52
70
83
139
241
295
521
1.50
1.05
0.70
0.55
0.46
0.38
0.32
0.27
0.22
0.18
0.15
2.20
1.55
1.04
0.84
0.70
0.66
0.54
0.40
0.33
0.27
LCP2-0.44-220
LCP2-0.36-330
LC P 3-6.64-2.2
LC P 3-4.46-4.7
LC P 3-3.00-10
LC P 3-2.42-15
LC P 3-2.00-22
LC P 3-1.62-33
LC P 3-1.34-47
LC P 3-1.12-68
LC P 3-0.94-100
LC P 3-0.76-150
LC P 3-0.62-220
LC P 3-0.50-330
LC P 3-0.42-470
LC P 3-0.36-680
0.44
0.36
6.64
4.46
3.00
2.42
2.00
1.62
1.34
1.12
0.94
0.76
0.62
0.50
0.42
0.36
220
330
2.2
4.7
10
15
22
33
47
68
100
150
220
330
470
680
784
960
5
12
26
37
55
84
127
188
250
346
478
671
1003
1500
0.22
0.18
3.32
2.23
1.5
1.21
1.00
0.81
0.67
0.56
0.47
0.38
0.31
0.25
0.21
0.18
Part Number
Full Load
Current
Electrical Specifications @ 25°C
Test voltage between windings: 500 Vrms
Operating temperature range: -40°C to +125°C
Climatic Category: IEC68-1 40/125/56
Test frequency: Inductance measured @ 10kHz/10mV
DCR
mOhm
mOhm
Energy
Storage
(µJ) *
8.8
18.8
40
60
88
132
188
272
400
600
880
8.8
18.8
40
60
88
132
188
272
400
600
36
64
148
232
344
532
820
1228
1504
2876
3464
28
52
112
208
280
332
556
964
1180
2084
7.0
7.2
7.2
7.0
7.1
7.2
7.1
7.2
7.2
7.2
7.3
16.4
16.0
16.4
16.0
16.2
16.0
21.2
20.2
15.8
16.1
880
1320
8.8
18.8
40
60
88
132
188
272
400
600
880
1320
1880
2720
3136
3840
20
48
104
148
220
336
508
752
1000
1384
1912
2684
4012
6000
15.8
15.8C
31.7
32.2
32.8
31.8
32.7
32.1
32.3
32.4
32.2
31.8
31.2
30.4
30.5
32.3
Full Load
Current
(ADC)
L0 (µH)
±15%
N o L o ad
THE TALEMA GROUP
•
DCR
Dimensions
Inches(Millimeters)
A
B
C
D
H
0.276
(7.0)
0.276
(7.0)
0.236
(6.0)
0.059
(1.5)
0.201
(5.1)
0.354
(9.0)
0.354
(9.0)
0.299
(7.6)
0.067
(1.7)
0.248
(6.3)
0.433
0.433
0.370
0079
0.268
(11.0)
(11.0)
(9.4)
(2.0)
(6.8)
World Wide Toroidal Specialists
LCP Series • Miniature High Current Toroidal Inductors
LO (µH )
±15%
N o L o ad
DCR
Energy
Storage
mOhm
(µJ) *
3.70
2.40
1.68
1.40
1.15
0.93
0.78
0.66
0.54
0.44
0.36
0.30
0.25
0.20
0.17
3.20
8.8
18.8
40
60
88
132
188
272
400
600
880
1320
1880
2720
4000
18.8
20
36
84
140
200
304
448
668
1000
1228
1880
2628
3600
5420
8168
28
42.5
43.2
43.2
43.2
43.6
43.9
43.1
43.4
42.9
42.8
42.0
44.0
43.6
40.2
42.5
73.9
16
2.25
40
64
71.6
28
38
52
72
86
128
218
298
451
604
934
1629
2483
3773
1.75
1.50
1.22
1.02
0.85
0.70
0.58
0.47
0.39
0.32
0.27
0.22
0.18
0.15
60
88
1.32
188
272
400
600
880
1320
1880
2720
4000
6000
8800
112
152
2.08
288
344
512
872
1192
1804
2416
3736
6516
9932
15092
71.6
71.6
72.6
72.1
71.3
71.6
73.4
71.5
73.8
70.9
73.2
71.4
71.6
72.9
LO (µH )
mOhm
C urrent
(ADC)
5
9
21
35
50
76
112
167
250
307
470
657
900
1355
2042
7
10
15
22
33
47
68
100
150
220
330
470
680
1000
1500
2200
±15%
N o L o ad
L C P 4-7 .40 -2 .2
L C P 4-4.8 0 -4.7
L C P 4-3 .3 6 -10
L C P 4-2 .8 0 -15
L C P 4-2 .3 0 -2 2
L C P 4-1.8 6 -3 3
L C P 4-1.5 6 -47
L C P 4-1.3 2 -6 8
L C P 4-1.0 6 -10 0
L C P 4-0 .8 8 -15 0
L C P 4-0 .7 2 -2 2 0
L C P 4-6 0 -3 3 0
L C P 4-0 .5 0 -47 0
L C P 4-0 .40 -6 8 0
L C P 4-0 .3 4-10 0 0
L C P 5 -6 .40 -4.7
7.40
4.80
3.36
2.80
2.30
1.86
1.56
1.32
1.08
0.88
0.72
0.60
0.50
0.40
0.34
6.40
2.2
4.7
10
15
22
33
47
68
100
150
220
330
470
680
1000
4.7
L C P 5 -4.5 0 -10
4.50
L C P 5 -3 .5 0 -15
L C P 5 -3 .0 0 -2 2
L C P 5 -2 .44-3 3
L C P 5 -2 .0 4-47
L C P 5 -1.7 0 -6 8
L C P 5 -1.40 -10 0
L C P 5 -1.16 -15 0
L C P 5 -0 .9 4-2 2 0
L C P 5 -0 .7 8 -3 3 0
L C P 5 -0 .6 4-47 0
L C P 5 -0 .5 4-6 8 0
L C P 5 -0 .44-10 0 0
L C P 5 -0 .3 6 -15 0 0
L C P 5 -0 .3 0 -2 2 0 0
3.50
3.00
2.44
2.04
1.70
1.40
1.16
0.94
0.78
0.64
0.54
0.44
0.36
0.30
Part N umber
Series C onnected
Full Load
DCR
D imensions
Inches(Millimeters)
A
B
2
Top View
Bottom View
D
4
Talema In
LCP4-4.80-4.7
Date Code
0.472
0.402
0.082
0.276
(12.0)
(10.2)
(2.2)
(7.0)
0.472
(12.0)
0.472
(12.0)
0.402
(10.2)
0.082
(2.2)
0.358
(9.1)
2
2
4
1
4
3
2
3
Series
Parallel
100%
D
100
A
80%
80
60%
60
A
3
% of Initial
Inductance
Curve A
A
H
0.472
Transformer
Pad Layout
Pin 1
1
3
D
(12.0)
Talema's engineering staff can assist in the design of other inductance values and sizes.
Notes:
Schematic
1. L(µH): Inductance is tested at 10mV and 10 kHz.
1
1
4
2. The µJoule rating (½LI²) is the ability of the
inductor to store energy.
Dimensions
C
40%
C
B
B
Front View
Side View
40
B
20%
20
0%
H
C
Dimensions: Inches (Millimeters)
Tolerance: ±0.010 (0.25) unless specified otherwise
Surface Coplanarity will be <0.006(0.15)
0
0 25% 50% 75% 100% 125% 150% 175% 200%
% OF RATED ADC CURRENT
Type
LCP-1
LCP-2
LCP-3
LCP-4 & 5
Pad Dimensions
A
B
8.0
7.0
10.0
9.0
12.0
11.0
13.0
12.0
C
2.5
3.0
3.0
3.5
Temperature Rise in °C from
Ambient
with ADC Current
Curve B
Parallel C onnected
Full Load
C urrent
(ADC)
D
2.5
3.0
3.0
3.5
Germany: Int.+4989-841 00-0 • Ireland: Int.+35 374 - 954 8666 • Czech Rep: Int.+420 377 - 338 351 • India: Int.+91 427 - 244 1325
http://www.talema-nuvotem.com
(02-07) LCP Series