T PL IA N M CO *R oH S Features Applications ■ Size: 8 mm diameter, 10 mm length ■ Balanced and symmetrical TRIGARD® ■ Telecommunications electronics ■ Industrial electronics ■ Consumer electronics ■ ■ ■ ■ ■ design High surge current rating Stable breakdown throughout life Long life Fail-Short available RoHS compliant* 2028 Series Long Life Heavy-Duty 3-Electrode Gas Discharge Tube Characteristics Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards. Model No. Characteristic 2028-23 DC Sparkover ±20 % @ 100 V/s 230 V 2028-25 2028-35 2028-42 250 V 350 V 420 V < 450 V/550 V < 650 V/750 V < 700 V/800 V < 850 V/950 V < 850 V/950 V < 1050 V/1150 V (1) Impulse Sparkover 100 V/µs (Typical/99 %) 1000 V/µs (Typical/99 %) (1) < 450 V/550 V < 650 V/750 V Impulse Sparkover voltage is defined as typical values of distribution. Impulse Transverse Delay ............................... 1000 V/µs..........................................................< 75 ns Insulation Resistance (IR) ............................... 100 V ................................................................> 1 GΩ Capacitance..................................................... 1 MHz ...............................................................< 2 pF Glow Voltage ................................................... 10 mA................................................................~ 70 V Arc Voltage ...................................................... 1 A .....................................................................~ 10 V DC Holdover Voltage (2) ................................... 135 V ................................................................< 150 ms Impulse Discharge Current (3) .......................... 30,000 A, 8/20 µs .............................................. 1 operation 20,000 A, 8/20 µs .............................................. 10 operations 5,000 A, 10/350 µs ............................................ 1 operation 200 A, 10/1000 µs ............................................. 300 operations 20 A, 10/1000 µs ............................................... 1500 operations Alternating Discharge Current ......................... 20 Arms, 1 second ............................................ 10 operations Operating Temperature............................................................................................................... -55 to +85 °C Climatic Category (IEC 60068-1)................................................................................................ 40 / 90 / 21 An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering process that does not exceed 210 °C. Notes: Network applied. (3) The Rated Impulse Discharge Current for TRIGARD® Gas Discharge Tubes is the total current equally divided between each line to ground. • At delivery AQL 0.65 Level II, DIN ISO 2859. (2) How to Order 2028 - nn - x n F LF Model Number Designator Voltage (Divided by 10) 23 = 230 V 35 = 350 V 25 = 250 V 42 = 420 V Leads A = No Leads / Cassette Applications C = 1.0 mm Lead Shape (See Product Dimension Drawings) Fail-Short Option Blank = Standard Product F = With Fail-Short Mechanism RoHS Compliancy LF = RoHS Compliant Product *RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. 2028 Series Long Life Heavy-Duty 3-Electrode Gas Discharge Tube Product Dimensions 2028-xx-A 2028-xx-C2 14.0 ± 0.4 (.551 ± .016) 10.2 ± 0.3 (.402 ± .012) 10.2 ± 0.4 (.402 ± .016) DIA. 2.5 ± 0.25 (.098 ± .010) 8.0 ± 0.2 (.315 ± .008) DIA. 8.0 ± 0.2 (.315 ± .008) DIA. 1.5 ± 0.3 (.059 ± .012) 15.0 ± 0.5 (.591 ± .020) 1.0 ± 0.04 (.040 ± .002) DIA. 2028-xx-C 1.0 mm dia. lead wire 4.5 ± 0.4 (.177 ± .016) 4.4 ± 0.3 (.173 ± .012) 4.4 ± 0.3 (.173 ± .012) 73.0 ± 0.3 (2.87 ± .012) 10.2 ± 0.4 (.402 ± .016) 2028-xx-C2F WITH FAIL-SHORT OPTION 8.51 ± 0.5 (.335 ± .020) 1.0 ± 0.04 (.040 ± .002) DIA. 7.5 ± 0.4 (.295 ± .016) 8.0 ± 0.2 (.315 ± .008) DIA. 11.9 ± 0.5 (.469 ± .020) 1.0 ± 0.04 (.040 ± .002) DIA. DIMENSIONS: MM (INCHES) Packaging Specifications Standard Packaging Quantity Model Bulk (Bag) 2028-XX-A 250 2028-XX-C 50 Tray Box 1000 300 2028-XX-C2 100 900 2028-XX-C2F 100 900 REV. D 11/15 Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications.