Specs

SPECIFICATION SHEET
JFW MODEL 50PA-504
BENCHTOP PROGRAMMABLE ATTENUATOR ASSEMBLY
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
Frequency Range
200-6000 MHz
Configuration
Two individually controlled solid-state programmable
attenuators
Enclosure Type
Benchtop
Impedance
50 Ohms nominal
Attenuation Range
0-63 dB in 1 dB steps
Startup/Default States
(configurable)
Maximum attenuation (see ATTEN STARTUP command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
VSWR
1.8:1 maximum
1.6:1 maximum
Attenuation Accuracy
(guaranteed monotonic)
± 0.50 dB
1-3 dB
± 0.75 dB
4-7 dB
± 1.00 dB
8-11 dB
± 1.25 dB or 4% 12-63 dB
(whichever is greater)
Insertion Loss
6.0 dB maximum
5.0 dB typical
RF Input Power
+20 dBm average
+25 dBm (no damage)
Switching Speed
1 microsecond typical
(after command is received and processed)
(3 milliseconds typical processing time)
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
200-800 MHz
800-6000 MHz
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-504
BENCHTOP PROGRAMMABLE ATTENUATOR ASSEMBLY
Remote Commands
Attenuator Control Commands:
Atten, Set Attenuator, Read Attenuator, Set All
Attenuators, Read All Attenuators, Read All Extended,
Fade Attenuator, Variable Attenuator Handover, Block,
Set Block, Read Block, Read All Blocks, Fade Block,
Variable Block Handover
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
SMA or N female
Operating Temperature Range
0ºC to +50ºC
Outline Drawing Numbers
092-5984 (50PA-504 N)
092-5985 (50PA-504 SMA)
ECR/ECN #
DATE
REV
08/06/2009
Page 2 of 2
APPR / DATE
ECR/ECN #
DATE
REV
APPR / DATE
CLK 08/06/2009
18146
01/22/2010
C
CLK 01/22/2010
24239
02/24/2015
D
TRS 02/25/2015
17674
09/11/2009
A
CLK 09/11/2009
17974
12/16/2009
B
CLK 12/16/2009
JFW FORM E-7-F REV F