Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PMA-098
TRANSCEIVER TEST SYSTEM
Frequency Range
2-6 GHz
Configuration
5 Port Transceiver Test System
(see block diagram 092-6730 for attenuator
addressing)
(all ports are bi-directional)
(full fan-out i.e. every path has its own
attenuator)
(the ADMIN password is located on rear panel)
Enclosure Type
19" rack mount @ 2RU high
Impedance
50 Ohms nominal
Attenuation Range
0-95 dB in 1 dB steps
Startup/Default States
(configurable)
Maximum attenuation (see ATTEN STARTUP command)
DHCP enabled (see NET command)
4 Ethernet users (see NET USERS command)
Prompt = "JFW>> " (see PROMPT command)
VSWR
1.7:1 maximum
1.5:1 typical
Attenuation Accuracy
± 0.7 dB
1-7 dB
± 1.0 dB
8-11 dB
± 1.25 dB or 4% 12-95 dB
(whichever is greater)
(guaranteed monotonic)
Insertion Loss
29 dB maximum
23 dB typical @ 2 GHz
27 dB typical @ 6 GHz
Power Divider Isolation
20 dB minimum
23 dB typical
RF Input Power
1 Watt average
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PMA-098
TRANSCEIVER TEST SYSTEM
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
Remote Commands
Attenuator Control Commands:
Atten, Set Path, Read Path, Read All Paths, Set
Attenuator, Read Attenuator, Set All Attenuators,
Read All Attenuators, Read All Extended, Fade
Attenuator, Variable Attenuator Handover, Block,
Set Block, Read Block, Read All Blocks, Fade
Block, Variable Block Handover, Set 2nd 32dB Bit
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot,
Uptime, Prompt
RF Connector
SMA female
Operating Temperature
Range
0ºC to +50ºC
Physical Size
See outline drawing 092-6729
ECR/ECN #
DATE
01/09/2015
Page 2 of 2
REV
APPR / DATE
ECR/ECN #
CLK 01/09/2015
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE