Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PMA-110
TRANSCEIVER TEST SYSTEM
Frequency Range
30-3000 MHz
Configuration
40 Port LC16 Limited Fan-out Transceiver Test System
(see 092-8614 for block diagram)
(see 092-8615 for attenuator address chart)
(all ports are bi-directional)
(the ADMIN password is located on rear panel)
Limited Fan-out Description
40 Port LC16 means that each of the 32 ports is
connection limited to only its 16 neighboring ports.
See 092-8615 for a connection example and the chart
for all internal connections through the matrix.
Enclosure Type
19 inch rack mount @ 23RU high
Impedance
50 Ohms nominal
Attenuation Range
0-95 dB in 1 dB steps
Startup/Default States
(configurable)
Attenuators to 95dB at startup (see ATTEN command)
DHCP enabled (see NET command)
4 Ethernet users (see NET USERS command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
VSWR
1.8:1 maximum
Attenuation Accuracy
± 0.50 dB
1-7dB
± 1.00 dB
8-11dB
± 1.25 or 3% 12-95dB
(whichever is greater)
(guaranteed monotonic)
Insertion Loss
45.7 dB typical
49.1 dB maximum
Power Divider Isolation
20 dB minimum
RF Input Power
1 Watt average
Switching Speed
2 microseconds
(after command is received and processed)
(3 milliseconds typial processing time)
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PMA-110
TRANSCEIVER TEST SYSTEM
Remote Commands
Attenuator Control Commands:
Atten, Set Path, Read Path, Read All Paths, Set
Attenuator, Read Attenuator, Set All Attenuators, Read
All Attenuators, Read All Extended, Fade Attenuator,
Variable Attenuator Handover, Block, Set Block, Read
Block, Read All Blocks, Fade Block, Variable Block
Handover
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
N, SMA or TNC female
Operating Temperature Range
0ºC to +50ºC
AC Supply
100-240 VAC @ 47-63 Hz
Outline Drawing Number
092-8613 (50PMA-110 SMA)
ECR/ECN #
DATE
04/25/2016
Page 2 of 2
REV
APPR / DATE
ECR/ECN #
TRS 04/25/2016
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE