Technical Data Plastic bodied limit switch Series ENK - ASI Description ASI ENK iw Article number 6073501023 Operating symbol 0mm 11-12 21-22 Operating diagram 2,4mm 3,2mm 5,5mm On Off Tolerance: Operating point ± 0,25 mm; Operating force ± 10 % Electrical data Operating voltage Operating current AS-i Specifications AS-i Inputs Parameter bits AS-i Address U I 26,5 … 31,6 V; via AS-interface, reverse-polarity proof < 30mA Profile S-0.B IO-Code: 0x0 ID-Code: 0xB ID-Code1: 0xF ID-Code2: 0xE Contact 1: Date bits D0/D1 = static 00 or dynamic code transmission Contact 2: Date bits D2/D3 = static 00 or dynamic code transmission no function preset address: 0 This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice! Date of issue: 07.12.2011 / Page 1 of 2 Document : 6073501023_en.doc / Last update : 3 / 2690-11 Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu Vorlage : 0850174281 Orig. 1 Technical Data Plastic bodied limit switch Mechanical data Enclosure Cover Indication Actuator Ambient air temperature Contact type Mechanical life Switching frequency Assembly Connection Plug connection Weight Installation position Protection type Thermoplastic, glass fibre reinforced Thermoplastic, glass fibre reinforced LEDs for slave and bus state Plunger (thermoplastic) -25° C … +70° C 2 NC (slow-action, Zb) 6 1 x 10 switching cycles ≤ 100/min 4 x M5 Plug connector M12 male 1: AS-i + 2: free 3: AS-i 4: free ≈ 0,15 kg operator definable IP65 acc. to EN 60529; DIN VDE 0470 T1 Actuation The push bolt actuator is mainly intended to be actuated along its axis. Side actuation will considerably reduce switch life. Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 EN 50295, EN ISO 13849-1 EU Conformity acc. to EMC Directive Safety Classification according 13849-1 to PL e MTTFd = high -10 PFD = 2,49 * 10 Notes The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent connector. This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice! Date of issue: 07.12.2011 / Page 2 of 2 Document : 6073501023_en.doc / Last update : 3 / 2690-11 Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu Vorlage : 0850174281 Orig. 1