PS_PS-DA0416-01.pdf

DC-AC INVERTER UNIT
PS-DA0416-01(S) (18 W DUAL OR QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC inverter is developed for dual and quad lamps.
Optimized for NEC Display: NL10276BC30-18
APPLICABLE LCD:
15inches quad lamps
Lamp Voltage 620 Vrms
Lamp Current 4 x 6,0 mArms
Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF for 2 pairs independent or 4 CCFL
Open lamp detection
Wide dimming range
Wide operating temperature
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
-10°C ~ +70°C
-20°C ~ +85°C
95 %RH max
L x B x H 200 x 44 x 14 mm
Unit : mm
Weight :60 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1 + CN6
Connector CN2 ~ CN5
Qty.
1
2
4
Input side CN1:
Pin No. Symbols
Ratings
Vin
10.8 ~ 13.2 Vdc
CN 1-1
Vin
10.8 ~ 13.2 Vdc
CN 1-2
GND
CN 1-3
GND
CN 1-4
Vrm
t
0
~
0.5
=
OFF
/
3.3 ~ Vin = ON
CN 1-5
N.C.
CN 1-6
Vbr
0 ~ 5.0 Vdc
CN 1-7
Material
UL94V-0 (FR-4 or CEM-3)
S7B-PH-K-S
SM02(8.0)B-BHS-1-TB
Note
t=1.6m m
JST or equal
JST or equal
Input side CN6:
Pin No. Symbols
Ratings
Vin
10.8
~ 13.2 Vdc
CN 1-1
Vin
10.8 ~ 13.2 Vdc
CN 1-2
GND
CN 1-3
GND
CN 1-4
Vrm t 0 ~ 0.5 = OFF / 3.3 ~ Vin = ON
CN 1-5
N.C.
CN 1-6
Vbr
0 ~ 5.0 Vdc
CN 1-7
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.0.1, 16th May 2014
DC-AC INVERTER UNIT
PS-DA0416-01(S) (18 W DUAL OR QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
Output side CN2 ~ CN5
Pin No.
Symbols
Ratings
Vhigh
620Vrm s (6.0 m Arm s )
CN 2-1
N.C.
CN2-2
Vlow
(GND)
CN 2-3
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Vin (V)
Vbr (V)
12±1.2
12±0.6
12±1.2
12±1.2
11.4
0.0
5.0
0.0
0.0
0.0
Specification
Tu (°C)
-10
-10
-10
-10
-10
~ +70
~ +70
~ +70
~ +70
~ +70
Min.
Typ.
Max.
5.5
50
1.550
6.0
15
1.67
55
1.800
6.5
2.17
60
-
Unit
Note
m Arm s
%
Adc
kHz
Vrm s
Dut y 100%
Dut y
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors as marked on mechanical drawing.
Please provide Vcc before applying any control signals into inverter.
Revere the sequence during power off which is control signal off first then Vcc.
Note 2:
TEST CIRCUIT :
F
A
Vin
10.8 ~ 13.2 V
1000:1
PROBE
F
Vopen
Iin
CN1-1
CN1-2
V
V
~
CL1
CN2-1
SW3
CN1-3
CN1-4
T1
Vrmt
0 / 3.3 Vdc
CN2-2 N.C.
RL1
A
~
a
V
b
SW1
CN1-6
CN1-7
Vbr
0 ~ 5.0 Vdc
CN4-1
CN6-3
CN6-4
SW4
b
SW2
Non Op erat ion
SW 2
Operat io of unit
a
Operat io n
b
Non Op erat ion
CN6-5
CN4-3
A
~
Iout
1
A
~
Iout
1
A
~
Iout
1
SW6
SW7
CN4-2 N.C.
CN5-1
N.C.
b
RL1
RL1
a
V
Operat io n
SW5
CN3-2 N.C.
CN6-1
CN6-2
V
Vrmt
0 / 3.3 Vdc
CN3-1
CN3-3
Iin
A
Vin
10.8 ~ 13.2 V
Operat io of unit
a
CN1-5
CN2-3
N.C.
Iout
1
SW 1
SW8
SW9
CN6-6
CN6-7
CN5-2 N.C.
Vbr
0 ~ 5.0 Vdc
CN5-3
RL1
SW10
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)