AC centrifugal fan RLG108/0042-3030LH forward-curved, single-intake with housing (without flange), Gas blower for conventional heating ebm-papst Landshut GmbH Hofmark-Aich-Straße 25 D-84030 Landshut Phone +49 (0) 871 707-0 Fax +49 (0) 871 707-465 [email protected] www.ebmpapst.com Nominal data Type RLG108/0042-3030LH Phase 1~ Nominal voltage VAC 230 Frequency Hz 50 Speed min-1 2400 Power consumption W 60 Current draw A 0.52 Max. temp. of flow medium °C 250 Air flow m3/h 145 Pressure increase Pa 300 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change Webdatenblatt · Seite 1 / 4 ebm-papst Landshut GmbH · Hofmark-Aich-Straße 25 · D-84030 Landshut · Phone +49 (0) 871 707-0 · Fax +49 (0) 871 707-465 · [email protected] · www.ebmpapst.com AC centrifugal fan RLG108/0042-3030LH forward-curved, single-intake with housing (without flange), Gas blower for conventional heating Technical description Weight 1.6 kg Insulation class "H" Cable Flat plug 6.3 x 0.8 Webdatenblatt · Seite 2 / 4 ebm-papst Landshut GmbH · Hofmark-Aich-Straße 25 · D-84030 Landshut · Phone +49 (0) 871 707-0 · Fax +49 (0) 871 707-465 · [email protected] · www.ebmpapst.com AC centrifugal fan RLG108/0042-3030LH forward-curved, single-intake with housing (without flange), Gas blower for conventional heating Product drawing 6,3 x 0,8 0° 13 87 Ø 56 161 18 Ø1 90 172 13 0° 42 57 3x Ø2,4 138 Webdatenblatt · Seite 3 / 4 ebm-papst Landshut GmbH · Hofmark-Aich-Straße 25 · D-84030 Landshut · Phone +49 (0) 871 707-0 · Fax +49 (0) 871 707-465 · [email protected] · www.ebmpapst.com RLG108/0042-3030LH AC centrifugal fan forward-curved, single-intake with housing (without flange), Gas blower for conventional heating Curves: Air performance Webdatenblatt · Seite 4 / 4 ebm-papst Landshut GmbH · Hofmark-Aich-Straße 25 · D-84030 Landshut · Phone +49 (0) 871 707-0 · Fax +49 (0) 871 707-465 · [email protected] · www.ebmpapst.com