LimitSwitches C2

Plastic-bodied compact
limit switches
Combi C2
For confined spaces
With two mounting options
Protection class IP 30
Hinged snap lid
q
l Compact switches for safety or control
applications
l 3 different contact configurations
available as slow-action and snap-action
l All normally-closed contacts are positive
break p
l Two channel safety control possible
l Galvanically isolated terminals, type Zb
l Approvals UL, CSA
l Rectangular cable entries (8.5 x 3.5 mm)
for 4 x 1-mm2 flexible lead
l 4 screw-type connections (M3,5) with
self-lifting clamps
l PBT enclosure, glass-fibre reinforced,
self-extinguishing UL 94-V0
l Lid, PC UL 94-V0
l 2 mm contact opening of slow-action
system according to EN 81-1 for lift
applications
Designation
Part number
Switching diagram
p positive break according to
IEC 947-5-1 Chap. 3
Za: changeover contact is not galvanically isolated
Zb: changeover contact is galvanically isolated
Slow-action contact/snap-action contact
Gasket inside (iw)/outside (w)
Contact travel mm
Tol. ± 0.25 mm
Switch angle degree
Tol. ± 3.5°
Actuating force N
Tol. ± 10%
Actuating torque Ncm
tol. ± 10%
Mounting
In
Out
Voltage
max.
Continuous current
max.
Making current, acc. to IEC 947-5-1 AC 15/DC 13
Switching frequency
max.
Mech. operational life – number of switching cycles
Ambient temperature
min./max.
a) 2 holes for M4 screws
Approvals
Weight
Delivery: ex-stock/built to order
Further switching functions
SA2
E2
b) 2 captive M3 nuts for end mounting
(depending on type)
11
12
13
14
13
14
21
22
23
24
23
24
Contact configuration
Switching element
Switch function
Switch contact Designation
Voltage
Continuous current
Slow-action
Snap-action
Slow-action
Snap-action
Slow-action
Snap-action
changeover
changeover
normally-closed
normally-closed
normally-open
normally-open
1NC/1NO
1NC/1NO
2NC
2NC
2NO
2NO
250
250
250
250
250
250
10
10
10
10
10
10
10
U1Z
SU1Z
A2Z
SA2Z
E2
SE2
V
V
V
V
V
V
A
A
A
A
A
A
SE2
Dimensions
All dimensions in mm
Switches
C2-U1Z
600.8101.001
C2-SU1Z
600.8351.002
C2-A2Z
600.8801.003
C2-U1Z St
600.8104.025
C2-SU1Z St
600.8354.026
C2-A2Z St
600.8804.027
C2-U1Z K
600.8107.019
C2-SU1Z K
600.8357.020
C2-A2Z K
600.8807.021
11
12
13
14
11
12
11
12
13
14
11
12
11
12
13
14
11
12
23
24
21
22
21
22
23
24
21
22
21
22
23
24
21
22
21
22
p Zb
l/–
–/–
p Zb
–/l
–/–
p Zb
l/–
–/–
p Zb
l/–
–/–
p Zb
–/l
–/–
p Zb
l/–
–/–
p Zb
l/–
–/–
p Zb
–/l
–/–
p Zb
l/–
–/–
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
0.02 kg
l/–
0.02 kg
l/–
0.02 kg
l/–
0.02 kg
l/–
0.02 kg
l/–
0.02 kg
l/–
0.02 kg
l/–
0.02 kg
l/–
0.02 kg
l/–
11
Designation
Switch part number
Actuator part number
Switching diagram
p positive break according to IEC 947-5-1 Chap. 3
Za: changeover contact is not galvanically isolated
Zb: changeover contact is galvanically isolated
Slow-action contact/snap-action contact
Gasket inside (iw)/outside (w)
C2-U1Z R
600.8116.013
–
C2-SU1Z R
600.8366.014
–
C2-A2Z R
600.8816.015
–
C2-U1Z o.M.+ H
600.8101.007
391.0190.259
C2-SU1Z o.M.+ H
600.8351.008
391.0190.259
C2-A2Z o.M.+ H
600.8801.009
391.0190.259
11
12
13
14
11
12
11
12
13
14
11
12
23
24
21
22
21
22
24
21
22
21
22
23
p Zb
l/–
–/–
p Zb
–/l
–/–
p Zb
l/–
–/–
Zb
l/–
–/–
Zb
–/l
–/–
Zb
l/–
–/–
Voltage
max.
Continuous current
max.
Making current, acc. to IEC 947-5-1 AC 15/DC 13
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
250 V AC
10 A
l
Switching frequency
max.
Mech. operational life – number of switching cycles
Ambient temperature
min./max.
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
100/min.
3 x 106
–30 °C/+80 °C
–22 °F/+176 °F
Approvals
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
Weight
Delivery: ex-stock/built to order
0.02 kg
l/–
0.02 kg
l/–
0.02 kg
l/–
0.03 kg
l/–
0.03 kg
l/–
0.03 kg
l/–
Contact travel mm
Tol. ± 0.25 mm
Switch angle degree
Actuating force N
Tol. ± 10%
Actuating torque Ncm
Tol. ± 10%
Tol. ± 3.5°
On
Off
Further switching functions
SA2
E2
SE2
11
12
13
14
13
14
21
22
23
24
23
24
Dimensions
All dimensions in mm
12