6018169006en

Technical Data
Safety switch
Series SLK – with separate actuator
Description
SLK-FVTU24-230MC-21-AR
Position monitoring
of guard locking
Article number
6018169006
Termination electromagnet
with contact position
E1, E2 without current
E1, E2 with current
Operating diagram
Actuator
withdrawn
Actuator
inserted
ON
OFF
Tolerances
Actuating force: ± 15%
Electrical data
Protection class
Contact elements
Rated insulation voltage
Conv. thermal current
Utilization category
Direct opening action
Short-circuit protective device
Electro magnets
Duty cycle
Temperature class
Inrush power consumption
Permanent power consumption
Switch operations permanent
Operating voltage
II, totally insulated
Ui
Ithe
250V
2,5A
AC-15, Ue /Ie 230V/2,5A
according to IEC/EN 60947-5-1, Annex K
4A gL
100% ED (at E1; E2)
B (130°C)
56VA (0,2s)
1,1VA
600/h
24V DC; 24, 110, 230V AC
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 05.04.2005 / Page 1 of 2
Document : 6018169006_en / Last update: 1 / 2236-05
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 2
Technical Data
Safety switch
Mechanical data
Enclosure
Cover
Actuating head
Actuator
Minimum actuating radius
Velocity for actuating
Extraction force
Interlocking principle
Unlocking
Hold on force
FZh
Ambient air temperature
Contact type
Switching principle
Mechanical life
Assembly
Connection
Conductor cross-sections
Cable entrance
Weight
Installation position
Protection type
Rmin
Vmax
Thermoplastic GV (UL94-V0)
Thermoplastic GV (UL94-V0)
Thermoplastic GV / Zn-GD
Separate actuator with dust protector (St / PA)
400mm
0,5m/s
≥ 27N
Spring force
a) magnetic force
b) auxiliary release
≤ 1500N acc. to GS-ET-19
-25°C ... +70°C
3 NC
3 slow make and break contact elements
6
1 x 10 switching cycles
(at max. 600 switch operations / h)
4 x M5
Cage tension spring
≤ 1,5mm² flexible
3 x M20x1,5
≈ 0,30kg
Operator definable
IP67 acc. to IEC/EN 60529
Actuation
4 different actuating directions achievable by rotating the actuating head.
Changing between horizontal and vertical actuating direction by setting the actuating head in the requested
direction.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
GS-ET-19
EU Conformity
Approvals
BG
CCSAUS B300 (same polarity)
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an
equivalent cable gland with adequate cable.
The switch may not be used as a mechanical stop.
When power is removed from the electromagnet (solenoid) the safety guard will be in locked position.
To operate the manual release loosen the screw and turn the hexagonal nut 90°.
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 05.04.2005 / Page 2 of 2
Document : 6018169006_en / Last update: 1 / 2236-05
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Vorlage : 0850174285 Orig. 2