Family data sheet

Product family datasheet
HALODIUM II
Outdoor flood- and spotlights
Areas of application
_ Facades and monuments
_ Parks
__
Product benefits
_ Ready for installation
Product features
_ Asymmetrical hammered reflector made of anodized aluminum
_ 5 mm shield made of tempered glass with a mesh overprint
_ Type of protection: IP66
_ Impact resistance: IK06
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 9
Product family datasheet
Prod.line drw, front, no
dimensions
__
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 9
Product family datasheet
Technical data
Electrical data
Light technical data
Dimensions & weight
Colors & materials
Product description
Operating mode
Lamp
wattage
Nominal
voltage
Mains
frequency
Light distribution
Length
Width
Height
Body material
HALODIUM II AZ 70 W SYM
LLCG
70 W
230 V
50 Hz
Symmetric
340.0 mm
214.0 mm
112.0 mm
Aluminum die-cast
HALODIUM II AZ 70 W
LLCG
70 W
230 V
50 Hz
Asymmetric
340.0 mm
214.0 mm
112.0 mm
Aluminum die-cast
HALODIUM II AZ 150 W
LLCG
150 W
230 V
50 Hz
Asymmetric
440.0 mm
260.0 mm
120.0 mm
Aluminum die-cast
HALODIUM II AZ 250 W
LLCG
250 W
230 V
50 Hz
Asymmetric
535.0 mm
437.0 mm
195.0 mm
Aluminum die-cast
HALODIUM II AZ 400 W
LLCG
400 W
230 V
50 Hz
Asymmetric
535.0 mm
437.0 mm
195.0 mm
Aluminum die-cast
HALODIUM II AZ 150 W SYM
LLCG
150 W
230 V
50 Hz
Symmetric
440.0 mm
260.0 mm
120.0 mm
Aluminum die-cast
HALODIUM II AZ 250 W SYM
LLCG
250 W
230 V
50 Hz
Symmetric
535.0 mm
437.0 mm
195.0 mm
Aluminum die-cast
HALODIUM II AZ 400 W SYM
LLCG
400 W
230 V
50 Hz
Symmetric
535.0 mm
437.0 mm
195.0 mm
Aluminum die-cast
HALODIUM II 70 W PROTECT. SHIELD
HALODIUM II 70 W PROTECT. SHIELD
HALODIUM II 150 W PROTECT.
SHIELD
HALODIUM II 250/400 W PROTECT.
SHIELD
HALODIUM II Louver Shield 150 W
__
Temperatures &
operating
conditions
Additional product data
Capabilities
Product description
Product
color
Cover material
Ambient
temperature range
Number of lighting
outlets
Equipped with lamp
Reflector type
Type of
installation
HALODIUM II AZ 70 W SYM
Anthracite
Tempered glass
-20…+35 °C
1
Yes
Symmetric
Surfacemounted
HALODIUM II 70 W PROTECT. SHIELD
HALODIUM II 70 W PROTECT. SHIELD
HALODIUM II 150 W PROTECT.
SHIELD
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 9
Product family datasheet
Product description
Temperatures &
operating
conditions
Additional product data
Capabilities
Product
color
Cover material
Ambient
temperature range
Number of lighting
outlets
Equipped with lamp
Reflector type
Type of
installation
HALODIUM II AZ 70 W
Anthracite
Tempered glass
-20…+35 °C
1
Yes
Asymmetric
Surfacemounted
HALODIUM II AZ 150 W
Anthracite
Tempered glass
-20…+35 °C
1
Yes
Asymmetric
Surfacemounted
HALODIUM II AZ 250 W
Anthracite
Tempered glass
-20…+35 °C
1
Yes
Asymmetric
Surfacemounted
HALODIUM II AZ 400 W
Anthracite
Tempered glass
-20…+35 °C
1
Yes
Surfacemounted
HALODIUM II AZ 150 W SYM
Anthracite
Tempered glass
-20…+35 °C
1
Yes
Surfacemounted
HALODIUM II AZ 250 W SYM
Anthracite
Tempered glass
-20…+35 °C
1
Yes
Surfacemounted
HALODIUM II AZ 400 W SYM
Anthracite
Tempered glass
-20…+35 °C
1
Yes
Surfacemounted
HALODIUM II 250/400 W PROTECT.
SHIELD
HALODIUM II Louver Shield 150 W
__
Certificates & standards
Product description
Adjustable
Dimmable
Type of connection
Holder designation
Accessories
Protection
class
Type of
protection
HALODIUM II AZ 70 W SYM
Yes
No
Terminal, 3-pole, max. 2,5
mm²
RX7s
Glass (4008321388322) /
Bracket (4008321380388)
/ Protection grid HAL 70
VS1 OSRAM
(4008321624871) /
Louver shield HALODIUM
70VS1 OSRAM
I
IP66
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 9
Product family datasheet
Certificates & standards
Product description
Adjustable
Dimmable
Type of connection
Holder designation
Accessories
Protection
class
Type of
protection
(4008321624857)
HALODIUM II 70 W PROTECT. SHIELD
HALODIUM II 70 W PROTECT. SHIELD
HALODIUM II 150 W PROTECT.
SHIELD
HALODIUM II 250/400 W PROTECT.
SHIELD
HALODIUM II Louver Shield 150 W
HALODIUM II AZ 70 W
Yes
No
Terminal, 3-pole, max. 2,5
mm²
RX7s
Glass (4008321388339) /
Bracket (4008321380388)
/ Protection grid HAL 70
VS1 OSRAM
(4008321624871) /
Louver shield HALODIUM
70VS1 OSRAM
(4008321624857)
I
IP66
HALODIUM II AZ 150 W
Yes
No
Terminal, 3-pole, max. 2,5
mm²
RX7s-24
Glass (4008321388346) /
Bracket (4008321380388)
/ Louver shield
HALOD150 VS1 OSRAM
(4008321624864) /
Protection grid HAL 150
VS1 OSRAM
(4008321624888)
I
IP66
__
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 5 of 9
Product family datasheet
Certificates & standards
Product description
Adjustable
Dimmable
Type of connection
Holder designation
Accessories
Protection
class
Type of
protection
HALODIUM II AZ 250 W
Yes
No
Terminal, 3-pole, max. 2,5
mm²
E40
Glass (4008321388360) /
Bracket (4008321380395)
/ Louver shield HALO
250/400 VS1 OSRAM
(4008321624901) /
Protection HALODIUM
250/400
(4008321624895)
I
IP66
HALODIUM II AZ 400 W
Yes
No
Terminal, 3-pole, max. 2,5
mm²
E40
Glass (4008321388360) /
Bracket (4008321380395)
/ Louver shield HALO
250/400 VS1 OSRAM
(4008321624901) /
Protection HALODIUM
250/400
(4008321624895)
I
IP66
HALODIUM II AZ 150 W SYM
Yes
No
Terminal, 3-pole, max. 2,5
mm²
RX7s-24
Glass (4008321388346) /
Bracket (4008321380388)
/ Louver shield
HALOD150 VS1 OSRAM
(4008321624864) /
Protection grid HAL 150
VS1 OSRAM
(4008321624888)
I
IP66
HALODIUM II AZ 250 W SYM
Yes
No
Terminal, 3-pole, max. 2,5
mm²
E40
Glass (4008321388360) /
Bracket (4008321380395)
/ Louver shield HALO
250/400 VS1 OSRAM
(4008321624901) /
Protection HALODIUM
250/400
(4008321624895)
I
IP66
__
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 6 of 9
Product family datasheet
Certificates & standards
Product description
Adjustable
Dimmable
Type of connection
Holder designation
Accessories
Protection
class
Type of
protection
HALODIUM II AZ 400 W SYM
Yes
No
Terminal, 3-pole, max. 2,5
mm²
E40
Glass (4008321388360) /
Bracket (4008321380395)
/ Louver shield HALO
250/400 VS1 OSRAM
(4008321624901) /
Protection HALODIUM
250/400
(4008321624895)
I
IP66
Country specific
categorizations
Product description
Protection
against
ignition
and fire
Order reference
HALODIUM II AZ 70 W SYM
F
HALODIUMII AZ 7
__
HALODIUM II 70 W PROTECT. SHIELD
HALODIUM II SYM
HALODIUM II 70 W PROTECT. SHIELD
HALODIUM II ASM
HALODIUM II 150 W PROTECT.
SHIELD
HALODIUM II SYM
HALODIUM II 250/400 W PROTECT.
SHIELD
HALODIUM IISYMA
HALODIUM II Louver Shield 150 W
LOUVER SHIELD H
HALODIUM II AZ 70 W
F
HALODIUMII AZ 7
HALODIUM II AZ 150 W
F
HALODIUMII AZ 1
HALODIUM II AZ 250 W
F
HALODIUMII AZ 2
HALODIUM II AZ 400 W
F
HALODIUMII AZ 4
HALODIUM II AZ 150 W SYM
F
HALODIUMII AZ 1
HALODIUM II AZ 250 W SYM
F
HALODIUMII AZ 2
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 7 of 9
Product family datasheet
Country specific
categorizations
Product description
Protection
against
ignition
and fire
Order reference
HALODIUM II AZ 400 W SYM
F
HALODIUMII AZ 4
__
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 8 of 9
Product family datasheet
Application advice
For more detailed application information and graphics please see product datasheet.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
__
June 8, 2016, 03:12:39
HALODIUM II
© 2016, OSRAM GmbH. All rights reserved.
Page 9 of 9