myc60w-series

PRELIMINARY
Isolated DC-DC Converters
MYC60W Series -- 60Watt
Bothhand USA
Features
z
Wide 4 : 1 Input Voltage Range (9~36V,18~75V)
z
Remote On/Off
z
Input / Output Isolation Voltage: 1.5k VDC
z
Operating Temperature Range: -55°C to +95°C(with derating)
z
Output Short Circuit Protection:
Hiccup & Auto Recovery
z
Over Voltage Protection: Clamp Mode
z
Over Temperature Protection
z
Lead Free Design, RoHS Compliant
z
Adjustable Output Voltage
z
Customer Design Available
Description
The MYC60W Series are isolated 60W DC/DC
converters. Designed with highly efficiency, allow the
operating temperature range of these units to be -55°C
to +95°C (with derating) in a five-sided shielded metal
case. Further features include wide 4 : 1 input voltage
range, remote on/off control, short-circuit protection,
over voltage protection and over temperature protection.
Applications
These converters are well suitable for battery operated
equipment, measurement equipment, telecom, wireless
network, Industry control system, everywhere where
isolated, tightly regulated voltages and compact size are
required.
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
Output
Output Current (mA)
Input Current (mA)
Input Voltage
Eff .(2) Capacitive
Voltage
(1)
Range
(%) Load, max.
Full. Load
No Load
Full Load
(Vdc) Min. Load
(uF)
Technical Specification
Model
Number
MYC60-24S1W
5
50
12000
110
3205
82
1000
9~36V
MYC60-24S2W Nominal:24VDC
12
50
5000
110
3086
85
330
MYC60-24S5W
24
90
2500
110
3086
85
100
MYC60-48S1W
5
50
12000
50
1582
83
1000
18~75V
MYC60-48S2W Nominal:48VDC
12
50
5000
50
1524
86
330
MYC60-48S5W
24
90
2500
50
1524
86
100
[email protected]
www.bothhandusa.com
PRELIMINARY
Bothhand USA
Isolated DC-DC Converters
MYC60W Series -- 60Watt
Input Specifications
Input voltage
24V nominal input
9-36Vdc
48V nominal input
18-75Vdc
Input filter
Pi type
Input surge voltage
24V input
50Vdc
(100ms max.)
48V input
100Vdc
Input reflected ripple current
Nominal Vin and full load
Start up time
Nominal Vin and constant resistive load
Remote ON/OFF
Converter: ON
Converter: OFF
200mAp-p typ.
150ms typ.
Open or 3.5V<Vr<12V
Short
(3)
or 0V<Vr<1.2V
Sourcing current of remote control pin
Nominal Vin
<0.2 mA
Idle input current (at Remote OFF state)
Nominal Vin
<20 mA
Environmental Specifications
Operating ambient temperature
-55°C to +95°C (with derating)
Maximum case temperature
+105°C
Storage temperature range
-55°C to +125°C
Relative humidity
95% RH max.
Temperature coefficient
±0.02% / °C max.
Output Specifications
Output power
Voltage accuracy
60 Watts max.
Full load and nominal Vin
Minimum load
±1%
See table
Line regulation
LL to HL at full load
±0.5%
Load Regulation
25% load to full load
±0.5%
Ripple and Noise (20MHz Bandwidth)
Over voltage protection
(Zener Diode Clamp)
5Vout & 12Vout models
100mVp-p max.
24Vout models
200mVp-p max.
5Vout models
6.2V
12Vout models
15V
24Vout models
27V
Capacitive load
Over load protection
See table
% of full load at nominal input
Thermal shutdown
110°C typ.
Short circuit protection
Hiccup, automatic recovery
Transient response settling time
50% load step change
Transient response over shoot
di/dt=0.8A/μs
[email protected]
110% min.
www.bothhandusa.com
7.7ms typ.
≤ ±8% of Vo
PRELIMINARY
Isolated DC-DC Converters
MYC60W Series -- 60Watt
Bothhand USA
General Specifications
Efficiency
Nominal input
See table
Isolation voltage
Input to output
1500VDC
Isolation resistance
500VDC
9
10 Ohms min.
Isolation capacitance
250pF typ.
Switching frequency
300kHz typ.
Reliability, calculated MTBF
5
7.18 × 10 Hrs
Cooling
Forced-air cooling
1.5m/s
Physical Specifications
Case material
Aluminum
Potting material
Silicon rubber (UL94V-0)
2.40 × 2.28 × 0.5 Inch
Dimensions
(61.0 × 57.9 × 12.7 mm)
Weight
97g (3.42oz) (typical)
260℃/10Sec (maximum)
Lead-free wave soldering
MYC60-24S5W
MYC60-24S5W
Power Derating Curve without Heatsink
Power Derating Curve with Heatsink
120
100
80
60
40
20
0
120
100
80
60
40
20
0
Output Power (%)
Output Power (%)
Soldering temperature
55
5
25
45
65
85
105
125
60
-55
-35
-15
Ambient Temp.TA (℃)
25
45
65
85
105
125
Ambient Temp.TA (℃)
MYC60-24S5W
MYC60-24S5W
Input voltage vs. Efficiency
Output Current vs. Efficiency
90
90
85
80
75
70
65
60
55
50
85
80
Efficiency %
Efficiency %
5
2.5
-15
2.25
-35
2
-55
75
70
65
60
55
50
30
33
36
Input voltage (V)
[email protected]
Output Current (A)
www.bothhandusa.com
1.75
27
1.5
24
1.25
21
1
18
0.75
15
0.5
12
0.25
9
PRELIMINARY
Isolated DC-DC Converters
MYC60W Series -- 60Watt
Bothhand USA
Note
1. Io below this value will not damage these converters, however, they may not meet all listed specifications.
2. Typical value, tested at nominal input and full load.
3. Short to -Vin (Pin 2).
Mechanical Dimensions
4-M3x0.5
(Through hole)
Pin Assignment
Pin
Single
1
+Vin
2
-Vin
Remote On/Off
3
4
-Sense
5
+Sense
6
+Vout
7
-Vout
8
Trim
4
1
2
Bottom view
3
5
6
7
8
Pin diameter: 1.0 [0.04]
Unit: mm [inch]
Tolerance: ±0.5 [0.02]
Heat-sink
Material: Aluminum
Weight: 35g (1.23oz) (without converter)
Note:
For volume orders, converters will be supplied
with heat-sink already mounted. Please contact
factory for quotation.
[email protected]
www.bothhandusa.com
PRELIMINARY
Isolated DC-DC Converters
MYC60W Series -- 60Watt
Bothhand USA
Remote Sense Application circuit
The Remote Sense function is used to compensate for the voltage drop incurred when the load is located physically
far away from the DC/DC converter providing its power. The Remote Sense pins are connected as close to the load as
possible. The DC/DC converter’s regulation specification is maintained across the points where the Remote Sense wires
are connected at the load. This will remove the effect of the voltage drop caused by the resistance of the wires used to
conduct the power from the DC/DC converter to the load. This is represented by RCL1 and RCL2. With the use of Remote
Sense, the effects of RCL1 and RCL2 are eliminated.
If the Remote Sense function is not used, the +Sense has to be connected to +Vout and the –Sense has to be
connected to –Vout as close to the DC/DC converter as possible.
RCL1
+Vout
+Vin
+Sense
Load
-Vin
-Sense
-Vout
RCL1 and RCL2 are line resisters
[email protected]
www.bothhandusa.com
RCL2