PLS-041B-3PPI S W I T C HI N G T HE S M A R T WAY PLS-041B-3PPI Standard Level Sensor Electrical Characteristics @ 25 °C Contact form Features B Contact rating max. Switching voltage max. Switching current max. W / VA 10 VDC 200 VAC 140 A 1 A 1.2 Breakdown voltage min. VDC 240 Total resistance max. mΩ 280 Carry current max. Polypropylene housing Suitable for food contact Covers a wide range of applications Customized types available Environmental Characteristics Operating temperature °C -20 to + 80 Storage temperature °C -30 to + 80 Mechanical Characteristics Approvals Density of float typ.* g / cm 3 0.7 Recommended minimum gravity of medium g / cm 3 Density of float + 20% * in delivery condition © PIC GmbH Dimensions in mm Ordering Information Packing Unit 10 pcs Weight per piece 11 g 118 g Weight per package Page 1 of 2 Rev.: 5.2 pls041b3ppi_ds_e_5.2 PIC Proximity Instrumentation Controls Kontaktbauelemente GmbH Nibelungenstr. 5 A 90530 Wendelstein, Germany Phone Fax +49 911 99 59 06-0 +49 911 99 59 06-99 [email protected] www.pic-gmbh.com PLS-041B-3PPI S W I T C HI N G T HE S M A R T WAY PLS-041B-3PPI Standard Level Sensor Material Information Material Colour Housing PP white Cable UL 1007, AWG 24, 4 mm stripped and tinned white Nuts PA66, M8, 1 pc preassembled white Float PP foam white Potting PU / Epoxy black Sealing ring Silicone white Operation View Remarks When mounted near ferromagnetic parts switching distance of PLS-041B-3PPI may vary. Electromagnetical influences and magnetic fields may change the switching behaviour of the Level Sensor. Mounting When mounted stem up, operating functions are reversed. Page 2 of 2 Rev.: 5.2 pls041b3ppi_ds_e_5.2 PIC Proximity Instrumentation Controls Kontaktbauelemente GmbH Nibelungenstr. 5 A 90530 Wendelstein, Germany Phone Fax +49 911 99 59 06-0 +49 911 99 59 06-99 [email protected] www.pic-gmbh.com