Product data sheet

Product datasheet
HE XT 35 W/840
LUMILUX T5 HE XT | Tubular fluorescent lamps 16 mm, high efficiency, long life, with G5 base
Areas of application
_ Offices
_ Public buildings
_ Industry
_ Shops
_ Tunnels, underpasses
_ Street lighting
_ Outdoor applications only in suitable luminaires
__
Product benefits
_ Much lower total cost of ownership, comprising investment, maintenance and relamping costs
_ Lower maintenance costs thanks to longer replacement intervals
_ Longer service life, so fewer lamps for waste disposal
_ Compatible with and easily exchangeable with conventional T5 lamps
_ High efficiency
Product features
_ Luminous efficacy: up to 104 lm/W
_ Extremely reliable: long life, low premature failure rate, 90 % luminous flux throughout their life
_ Extremely long average lifetime: up to 45,000 h (with QUICKTRONIC ECG)
_ Good color rendering group: 1B (R : 80…89)
a
_ Dimmable
June 16, 2016, 13:37:51
HE XT 35 W/840
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 6
Product datasheet
Technical data
Electrical data
Nominal wattage
35.00 W
Rated lamp efficacy (HF data 25 °C)
89 lm/W
Rated wattage
35.50 W
Photometrical data
__
Color rendering index Ra
≥80
Rated luminous flux
3320 lm
Luminous flux at 25 °C
3320 lm
Luminous flux at 35 °C
3650 lm
Light color
840
Color temperature
4000 K
Nominal luminous flux
3320 lm
Light color (designation)
LUMILUX Cool White
Rated LLMF at 2,000 h
0.95
Rated LLMF at 4,000 h
0.93
Rated LLMF at 6,000 h
0.92
Rated LLMF at 8,000 h
0.90
Rated LLMF at 12,000 h
0.90
Rated LLMF at 16,000 h
0.90
Rated LLMF at 20,000 h
0.89
Dimensions & weight
Tube diameter
16 mm
Length
1449 mm
Length with base excl. base pins/connection
1449.00 mm
Diameter
16.0 mm
June 16, 2016, 13:37:51
HE XT 35 W/840
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 6
Product datasheet
Maximum diameter
16.0 mm
Temperatures & operating conditions
Rated ambient temp.w.max.luminous flux
35.0 °C
Lifespan
__
Service life
30000 h
Lifespan
45000 h
Rated lamp survival factor at 2,000 h
0.99
Rated lamp survival factor at 4,000 h
0.99
Rated lamp survival factor at 6,000 h
0.99
Rated lamp survival factor at 8,000 h
0.99
Rated lamp survival factor at 12,000 h
0.99
Rated lamp survival factor at 16,000 h
0.99
Rated lamp survival factor at 20,000 h
0.98
Operation mode LLMF/LSF
HF
Rated lamp life time
45000 h
Nominal lamp life time
45000 h
Additional product data
Base (standard designation)
G5
Mercury content
2.5 mg
Appropriate disposal acc. to WEEE
Yes
Product remark
For ECG operation only/Lamp designed for internal
luminaire temperatures of 30…40 °C; optimum
luminous flux achieved at 35 °C
Capabilities
Dimmable
Yes
Suitable for indoor
Yes
Certificates & standards
Energy efficiency class
A+
Energy consumption
40 kWh/1000h
June 16, 2016, 13:37:51
HE XT 35 W/840
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 6
Product datasheet
Light Distribution
Spectral power distribution
__
Guarantee
Safety advice
In case of lamp breakage: www.osram.com/brokenlamp
June 16, 2016, 13:37:51
HE XT 35 W/840
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 6
Product datasheet
Circuit diagram
Circuit diagram
Logistical Data
Product code
Product description
Packaging unit
(Pieces/Unit)
Dimensions (length
x width x height)
Volume
Gross weight
4052899028661
HE XT 35 W/840
Shipping carton box
20
1482 mm x 104 mm
x 83 mm
12.79 dm³
3490.00 g
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
__
References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit
www.osram.com/system-guarantee
For more information on QUICKTRONIC electronic control gear go to
www.osram.com/QUICKTRONIC
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
June 16, 2016, 13:37:51
HE XT 35 W/840
© 2016, OSRAM GmbH. All rights reserved.
Page 5 of 6
Product datasheet
HE XT 35 W/840
LUMILUX T5 HE XT | Tubular fluorescent lamps 16 mm, high efficiency, long life, with G5 base
Product name
Product name ECG
EAN
Nominal
current
Nominal wattage + Power
loss
Luminous flux at 35 °C
Number of
lighting
outlets
HE XT 35 W/840
QT-FIT 5 1x14-35
4008321971234
0.17 A
38.00 W
3200 lm
1
QT-FIT 5 2x14-35
4008321971258
0.35 A
78.00 W
3300 lm
2
QTi 1x14/24/21/39 GII
4008321383334
0.18 A
39.00 W
3300 lm
1
QTi 1x28/54/35/49 GII
4008321383358
0.17 A
38.00 W
3300 lm
1
QTi 1x35/49/80 DIM
4050300870540
0.17 A
37.80 W
3300 lm
1
QTi 1x35/49/80 GII
4008321383372
0.17 A
38.00 W
3300 lm
1
QTi 2x14/24/21/39 GII
4008321383396
0.35 A
76.00 W
3300 lm
2
QTi 2x28/54/35/49 GII
4008321383419
0.35 A
76.00 W
3300 lm
2
QTi 2x35/49/80 DIM
4050300870984
0.34 A
74.00 W
3300 lm
2
QTi 2x35/49/80 GII
4008321658951
0.36 A
77.00 W
3400 lm
2
QTi 2x35/49 DIM
4050300870670
0.33 A
74.50 W
3300 lm
2
QTi DALI 1x35/49/80 DIM
4050300870342
0.17 A
37.80 W
3300 lm
1
QTi DALI 2x35/49/80 DIM
4050300870441
0.34 A
74.00 W
3300 lm
2
QTi DALI 2x35/49 DIM
4050300870465
0.33 A
74.50 W
3300 lm
2
QTP5 1x14-35
4008321329035
0.17 A
38.00 W
3300 lm
1
QTP5 2x14-35
4008321329073
0.33 A
75.00 W
3300 lm
2
__
June 16, 2016, 13:37:51
HE XT 35 W/840
© 2016, OSRAM GmbH. All rights reserved.