MEMORY HiCORDER MR8827 Recorders 64 32 analog channels + ch 32 logic channels High-speed Isolated testing The Memory HiCorder MR8827 achieves isolated input between the main unit and channel or between channels, at a maximum sampling speed of 20 MS/s on all channels. It provides mixed recording that combines 32 analog channels and 32 logic channels, and logic input can be expanded up to 64 channels. Welcome to the next generation of Hioki Memory HiCorders that deliver multichannel waveform recording of a diverse array of signals to meet complex and demanding applications. * When using 64 logic channels, 28 analog channels are available. 2 MR8827 - Evolving to the Next Stage of High-Speed Waveform Recording 3 The high-performance 8826 delivered the most analog channels out of all portable-type Memory HiCorders. The new MEMORY HiCORDER MR8827 inherits that concept and evolves even further. 20x Sampling Speed 1MS/s 2x Logic Input Channels 20MS/s 32ch 64ch A maximum of 8 logic probes can be inserted in the main unit. Use of 2 Logic Unit 8973 will add 8 more connections, supporting 64 channel The sampling speed (for all channels A/D converter integrated in the input amp logic signal input. (This reduces the simultaneously) increased by 20 times, while maintaining isolated input. 8x Internal Memory Capacity 64MW 512MW number of available analog channels Logic Unit 8973 to 28.) Storage Devices and Media USB Memory/CF Card SSD (Solid State Drive) With 8 times more internal memory Use various storage devices and capacity from 64 MW to 512 MW, media with more capacity and faster you can now record signals of fast writing speeds than conventional events easily and for extended pe- drives or PC cards. The optional riods of time. internal SSD has 128 GB of capacity so you can store large amounts of data. LCD Resolution 3x PC Transfer Speed 3 times faster transfer speed! Transferring speed of stored data from internal memory or SSD to the PC has greatly increased. Conventional transfer time 10.4 inch TFT 10.4 inch SVGA 640×480 800×600 Overlapping waveforms are easier to identify now with a new high resolution LCD. Data transfer time → 2x Paper Feeding Speed 25mm/sec Easy Setup of Recording Paper 50mm/sec Use of a high-speed thermal printer gives you 2 times the printing speed. No more hassles of feeding re c o rding pa p e r b et we e n t h e rubber roller and the thermal head. Just drop it in to set it up. 4 Record Various Signal Input Support / Optional Units ANALOG UNIT 8966 DIGITAL VOLTMETER UNIT MR8990 HIGH RESOLUTION UNIT 8968 DC/RMS UNIT 8972 Low voltage High voltage Contacts LOGIC UNIT 8973 Current CURRENT UNIT 8971 Various amps Transducers Sensors / industrial meters Supply voltage Inverter Primary / Secondary voltage Motor voltage, etc. Voltage / non-voltage contacts Relay signals AC / DC signals Supply current Inverter Current Motor current, etc. Strain gauge converter Strain STRAIN UNIT 8969 Dynamic strain / Acceleration / Vibration Pressure / Weight, etc. Temperature Thermocouples K, J, E, T, N, R, S, B, W Frequency Encoders, etc. Rotating pulse TEMP UNIT 8967 FREQ UNIT 8970 View High Resolution LCD Conventional devices used a 640×480 dot TFT LCD, but Scroll Scroll Scroll through the waveform to the next-generation MR8827 uses an 800×600 dot SVGA high resolution LCD to make check all or just part of it. Shrunk waveform it eve n e asier to ide ntif y overlapping measured waveforms. Expand / shrink Expanded waveform Not only can you expand or shrink the time axis or verti- Expand/Shrink + − cal axis, you can also split the screen to check the expanded waveform of the shrunk waveform. 5 Expansive Input Channels Sampling Speed and Recording Time A maximum of 16 modules can be connected on the rear side. Memory functions The main unit also has connectors for connecting 8 logic probes. Recorder functions Maximum recording length Time axis range/div Samplingspeed 32 channels 10 ms 160,000 div 5 µs The MR8827 differentiates itself from typical oscilloscopes by providing complete isolation for the input of each channel, and between each channel and the main frame, enabling you Isolation element to handle electrical potential differences among multiple signals without any concern. 0.8 s 10 µs 20 µs 100 ns 200 ns 1.6 s 3.2 s 100 µs 1 µs 16 s 50 µs Isolated Input for Security 50 ns 200 µs 500 µs 1 ms 2 ms 5 ms 10 ms 500 ns 2 µs 5 µs 8s 32 s 1 min 20 s 10 µs 2 min 40 s 50 µs 100 µs 13 min 20 s 26 min 40 s 20 µs 5 min 20 s 20 ms 50 ms 200 µs 500 µs 500 ms 1s 2s 5 ms 10 ms 20 ms 22 h 13 min 20 s 1 d 20 h 26 min 40 s 3 d 16 h 53 min 20 s 10 s 100 ms 18 d 12 h 26 min 40 s 30 s 300 ms 55 d 13 h 20 min 0 s 50 s 1 min 100 s 500 ms 600 ms 1s 92 d 14 h 13 min 20 s 111 d 2 h 40 min 0 s 185 d 4 h 26 min 40 s 5 min 3s 100 ms 200 ms 5s 2 min 1 ms 2 ms 50 ms 1.2 s Time axis range/div 53 min 20 s 2 h 13 min 20 s 4 h 26 min 40 s 8 h 53 min 20 s 9 d 6 h 13 min 20 s 222 d 5 h 20 min 0 s 20 ms 50 ms 100 ms 200 ms 500 ms 1s Maximum recording length 80,000 div 13 min 20 s 26 min 40 s 1 h 6 min 40 s 2 h 13 min 20 s 4 h 26 min 40 s 11 h 6 min 40 s 22 h 13 min 20 s 2s 1 d 20 h 26 min 40 s 10 s 30 s 9 d 6 h 13 min 20 s 27 d 18 h 40 min 0 s 5s 50 s 1 min 100 s 2 min 5 min 10 min 30 min 1h 4 d 15 h 6 min 40 s 46 d 7 h 6 min 40 s 55 d 13 h 20 min 0 s 92 d 14 h 13 min 20 s 111 d 2 h 40 min 0 s 277 d 18 h 40 min 0 s - abbreviated - abbreviated - abbreviated - Sampling period: 1 µs, 10 µs, 1 ms, 10 ms, 100 ms *Select within 1/100 of the time axis. Also limited by combination with the time axis setting for memory recording. - abbreviated - A4 Size Printer Scanning Scanning Scan data at the cursor and the waveform's cross point. Print in fine detail, with 2 times the paper feeding speed. Get a printout of Cutout Specify the segment to save as binary or CSV data. Cutout enlarged waveforms on A4 size paper so you can check them easily on-site. 6 Save Save on devices and media Input signals af ter A / D conversion stored in internal memory can be saved SSD Input Input Transfer on the optional internal SDD, USB mem- CF card ory, or CF card. USB Memory stick A/D conversion Transfer to PC Save on devices and media Store in internal memory LAN Connection USB Connection Check and analyze data saved in the Use the H T T P function to operate Use a PC to retrieve data saved on internal SSD, USB memory, or CF card, MR8 827 with a browser on a PC devices and media such as internal by transferring it to a PC, via LAN or connected via LAN. You can also use memory, SSD, or CF card connected to USB. the FTP function to retrieve data from the main unit, via USB. internal memor y, devices or media connected to the main unit. LAN FTP HTTP USB Analyze WAVE PROCESSOR 9335 LAN COMMUNICATOR 9333 (Option) (Option) ● Waveform display, calculations ● Print function ● Auto-save waveform data to PC ● Remote control via LAN connection ● Save in CSV format and transfer to spreadsheet programs ■ 9335 Brief Specifications ■ 9333 Brief Specifications Operating Windows 8/7 (32/64-bit), Vista (32-bit), XP environment Operating Windows 8/7 (32/64-bit), Vista (32-bit), XP, (9333 ver.1.09 or later) environment Functions Print - Display functions: Waveform display, X-Y display, Cursor function, etc. - File loading: Readable data formats (.MEM, .REC, .RMS, .POW) / Maximum loadable file size: Maximum file size that can be saved by a given device (file size may be limited depending on the computer configuration) - Data conversion: Conversion to CSV format, Batch conversion of multiple files, etc. - Print function: Printing image file output (expanded META type, ".EMF") - Print formatting: 1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up, preview, hard copy Functions - Auto-saves waveform data to PC, Remote control of Memory HiCorder (by sending key codes and receiving images on screen), print report, print images from the screen, receive waveform data in same format as waveform files from the Memory HiCorder (binary only) - Waveform data acquisition: Accept auto-saves from the Memory HiCorder, same format as auto-save files of Memory HiCorder (binary only), print automatically with a Memory HiCorder from a PC. The Memory HiCorder’s print key launches printouts on the PC - Waveform viewer: Simple display of waveform files, conversion to CSV format, etc. 7 A4 size thermal printer 10.4 inch SVGA waveform monitor CF card slot USB 2.0 Rack handle USB 2.0 (connect to the PC) LAN External control connector Input module slots (maximum 16 modules) iPad App for Memory HiCorder HMR Terminal Free app (exclusively for iPad) downloadable from the App Store ● Freely control waveforms using iPad's gesture controls ● Multi-channel support – up to 32 channels (with MR8827, MR8740) of waveform data at your fingertips ● Operate the Memory HiCorder via network You can change settings, and monitor waveforms during measurement. Logic probe connectors (for 8 units) Wave Viewer Wv (Bundled software) ● Check waveforms with binary data on a PC ● Save data in CSV format and transfer to spreadsheet programs *New function on Ver 2.0 ■ HMR Terminal Brief specifications (free software) Operating iOS on the iPad (Apple Inc. ) environment Functions - Data acquisition: Send to iPad via FTP using a WiFi router, or load to iPad via iTunes (PC app) - Intuitively operate waveform level searches, maximum / minimum / average values, zero position adjustment, and more at your fingertips - Waveform monitoring - Meter setting * Logic waveforms and computational waveforms are not supported. ■ Wave Viewer (Wv) Brief Specifications Operating Windows 8/7 (32/64-bit), Vista (32-bit), XP, 2000 environment Functions - Simple display of waveform files - Convert binary data files to text format, CSV, etc. - Scroll function, enlarge/reduce display, jump to cursor/trigger position, etc. 8 Ptionerfect for recording a combinaof analog and logic signals that require multiple channels. Electric power Power electronics Transformer Interruption Tests Interchannel isolation allows for safe circuit connections. Simultaneous high-speed sampling can record waveforms before and after the interruption, and allows you to input many control and circuit signals. Battery Charge/Discharge Tests Input and test the voltage of each battery cell. The MR8827 is built for up to 400 V DC input, protecting it even if high voltage is applied when there is a short-circuit. Inverter / UPS Test Perfect for inverter and UPS evaluation and start-up tests. Record using both logic (control signals) and analog input (primary/secondary voltage or current for a UPS or inverter). Power Monitor and Logger INV By loading the analog output for the effective value (instant Power power / voltage / current, etc.) calculated by the power analyzer, or by importing the waveform output from the power analyzer to MR8827, you can observe data for longterm tests or irregular waveforms. Motor Load Power POWER ANALYZER MR8827 Torque Meter D/A output PW6001 or other Torque / Rotation 9 Rsignals ecord a diverse array of simultaneously Mechatronics Automotive ECU Evaluation The 32 analog channels and 32 logic channels work great for IN OUT observing input and output signals of an Engine Control Unit. Over 4 hours of recording can be achieved with 1 ms sampling. Engine Strain Measurements Use the Strain Unit 8969 to perform strain measurements of up to 32 channels. You can use the numerical value calculation function to automatically calculate the maximum value, minimum value, and P-P value of strain waveforms. Vibration / Endurance Tests Use the long 512 M W memor y to obser ve vibration waveforms easily (Memor y function). Also, with the recorder function, you can perform long-term observation by capturing the waveform peaks while sampling at high speeds. Injection Molder Evaluation Along with a pneumatic pressure or valve closure, you can record the logic input from control signals. Select from a rich lineup of Hioki input units that support a wide range of sensors and converters. MR8827 10 Main unit Specifications Basic specifications (product guaranteed for one year) MEMORY (high-speed recording) Measurement functions MEMORY (high-speed recording) RECORDER (real-time recording) X-Y RECORDER (X-Y real-time recording) FFT (frequency analysis) Time axis 5 μs to 5 min/div (100 samples/div) 26 ranges, External sampling (100 samples/div, or free setting), Time axis zoom: ×2 to ×10 in 3 stages, compression: 1/2 to 1/20000 in 13 stages Main unit OS μ ITRON (Non-Windows OS) Sampling period 1/100 of time axis range (minimum 50 ns period) Recording length Built-in presets: (at 4, 8, 16ch mode) 25 to 20000 div, (at 4, 8 ch mode) 25 to 500000 div (at 4 ch mode) 25 to 1000000 div Arbitrary presets: setting in 1 div steps, Max. 1280000 div (at 4ch mode), 640000 div (at 8ch mode), 320000 div (at 16ch mode), 160000 div (at 32ch Pre-trigger Record data from before the trigger point at 0 to +100% or -95% of the recording length in 15 stages, or in 1 div step settings [16 analog input modules]: 32 analog channels + 32 logic channels (logic Number of channels (Max.) probe terminals standard, logic has common GND) [14 analog input modules + 2 logic input modules]: 28 analog channels + 64 logic channels (standard 32 channels + 32 channels in Logic unit 8973 ×2) mode) * Max. up to two modules of the Logic Unit 8973, the Current Unit 8971 up to four modules Maximum sampling rate 20 MS/second (all channels simultaneously) Internal memory 16MW/ch (total capacity 512MW memory), 16MW/ch (using 32 analog channels), 32MW/ch (using 16 analog channels), 64MW/ch (using 8 analog channels), 128MW/ch (using 4 analog channels) Data storage media CF card slot (standard) ×1 (up to 2GB, FAT, or FAT-32 format), USB port ×2 (USB 2.0) Backup battery life Clock and parameter setting backup: at least 10 years (reference value at 25°C) External trigger input, Trigger output, External sampling input, GND, External control conTwo external outputs (GO/NG output), Three external inputs (start/IN1, stop/ nectors IN2, save/IN3) LAN: 100BASE-TX (DHCP, DNS supported, FTP server, HTTP server) External interfaces USB: USB 2.0 compliant, series A receptacle ×1, series B receptacle ×1, (File transfer SSD/ CF card to PC, or remote control from PC) Environmental condi- Operation: 0°C to 40°C (32°F to 104°F), 20% to 80% rh tions (No condensation) Storage: -10°C to 50°C (14°F to 122°F), 90% rh or less Standards Safety: EN61010 EMC: EN61326, EN61000-3-2, EN61000-3-3 Power supply AC 100 to 240 V, 50/60 Hz Power consumption 220 VA max. (when not using the printer), 350 VA max. (when using the printer) • Simultaneous calculation for up to 16 selected channels Average value, effective (rms) value, peak to peak value, maximum value, time to maximum value, minimum value, time to minimum value, period, frequency, rise time, fall time, standard deviation, area value, X-Y area value, specified level time, specified time level, pulse width, Numerical calculation duty ratio, pulse count, four arithmetic operations, time difference, phase difference, high-level and low-level • Calculation result evaluation output: GO/NG (with open-collector 5 V output) • Automatic storing of calculation results • For up to 16 freely selectable channels, the following functions can be performed Four arithmetic operations, absolute value, exponentiation, common logarithm, square root, moving average, differentiation (primary, Waveform processing secondary), integration (primary, secondary), parallel displacement along time axis, trigonometric functions, reverse trigonometric functions, integration time correction for each NPLC setting, auto-saves of calculation results Memory segmentation • Max. 1024 blocks, sequential storage, multi-block storage Other functions 401 mm (15.79 in)W × 233 mm (9.17 in)H × 388 mm (15.28 in)D, 12.6 kg Dimensions and mass (444.4 oz) (main unit only) Supplied accessories Instruction manual ×1, Application disk (Wave Viewer Wv, Communication commands table) ×1, Power cord ×1, Input cord label ×1, USB cable ×1, Printer paper ×1 (when equipped with a printer unit), Roll paper attachment ×2 (when equipped with a printer unit) • X-Y waveform synthesis (1 screen, 4 screens) • Overlay (always overlay when started/overlay only required waveforms) • Automatic/ Manual/ A-B cursor range printing/ Report printing • Logging is not available Memory recording method Sampling period Sampling is done at the set sampling period. PRINTER UNIT U8350 (Factory-installed option) Features Printer paper one-touch loading, high-speed thermal printing Recording paper 216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll (use the 9231 paper) Recording witdh: 200 mm (7.87 in) 20 division full scale, 1 div = 10 mm (0.39 in) 80 dots Recording speed Max. 50 mm (1.97 in)/sec Paper feed density 10 lines/mm RECORDER (Real-time recording) 10 ms to 1 hour/div, 19 ranges, time axis resolution 100 points/div Time axis Note: Out of data acquired at selected sampling rate, only maximum and minimum value data determined using 100 points/div units are stored Time axis compression selectable in 13 steps, from × 1/2 to × 1/20000 Sampling rate 1/10/100 µs 1/10/100 ms (selectable from 1/100 or less of time axis) Supported Display * Real-time printing is possible at time axis settings slower than 500 ms/div Display 10.4 inch SVGA-TFT color LCD (800 × 600 dots) (Time axis 25 div × Voltage axis 20 div, X-Y 20 div × 20 div) Languages English, Japanese, Korean, Chinese Waveform display zoom/compression Time axis: ×10 to ×2 (zoom at MEMORY function only), ×1, ×1/2 to ×1/20000, Voltage axis: ×100 to ×2, ×1, ×1/2 to ×1/10 Recording length Built-in presets of 25 - 50000 div, or ‘‘Continuous’’ or arbitrary setting in 1 div steps (max. 80000 div) Variable display Upper/Lower limit set, display/div set Waveform memory Store data for most recent 80000 div in memory Scaling 10:1 to 1000:1, automatic scaling for various probes Manual scaling (conversion ratio setting, 2-point setting, unit setting) Auto save Data is automatically saved on CF card, USB memory stick or internal SSD after measurement stops Comment input Alphanumeric input (title, analog and logic channels) Simple input, history input, phrase input Other functions • Manual/ A-B cursor range printing/ Report printing • Logging is not available Logic waveform Display point move 1 % step, Line width 3 types Display partition Max. eight divisions Monitor function • Input level monitor • Numerical value (Sampling 10kS/s fixed, refresh rate 0.5s) Other display functions • Waveform inversion (positive/negative) • Cursor measurement (A, B, 2-cursor, for all channels) • Vernier function (amplitude fine adjustment) • Zoom function (horizontal screen division, zoomed waveform shown in lower section) • 16 selectable colors for waveform display • Zero position shift in 1% steps for analog waveform • Global zero adjust for all channels and all ranges Real-time printing * Delayed print is performed when recording length is not set to ‘‘Continuous’’ and time axis setting is 10 ms - 200 ms/div * When recording length is set to ‘‘Continuous’’ and time axis setting is 10 ms 200 ms/div, manual printing can be performed after measurement stop Recorder recording method High-speed sampling is performed at the set sampling frequency, culling data Culling save other than the maximum and minimum values to create the recording data of a certain High-speed sampling time. Sampling period Max. Min. 11 X-Y RECORDER (X-Y real-time recording) Trigger functions Sampling period 1/10/100 ms (dot), 10/100 ms (line) Trigger mode MEMORY (high-speed recording), FFT: Single, Repeat, Auto RECORDER (real-time recording): Single, Repeat Recording length Continuous Trigger sources CH1 to CH32 (analog), Standard Logic 32ch + Logic Unit (Max. 2 units 32 channels), External (a rise of 2.5V or terminal short circuit), Timer, Manual (either ON or OFF for each source), Logical AND/OR of sources Screen, Printing Split screen (1 or 4), Manual printing only Number of X-Y 1 to 8 phenomenon X-Y channel setting Any 8 channels out of 16 can be selected for X axis and Y axis respectively X-Y axis resolution 25 dots/div (screen), horizontal 80 dots/div × vertical 80 dots/div (printer) Waveform memory Sampling data for last 16000000 points are stored in memory Pen up/down Simultaneous for all phenomena External pen control Possible via external input connector (simultaneous up/down for all • Level: Triggering occurs when preset voltage level is crossed (upwards or downwards) Trigger types phenomena) FFT Analysis mode Storage waveform, Linear spectrum, RMS spectrum, Power spectrum, Density of power spectrum, Cross power spectrum, Auto-correlation function, Histogram, Transfer function, Crosscorrelation function, Impulse response, Coherence function, 1/1 Octave analysis, 1/3 Octave analysis, LPC analysis, Phase spectrum Analysis channels Selectable from all analog input channels Frequency range 133 mHz to 8 MHz, External, (resolution 1/400, 1/800, 1/2000, 1/4000) Number of sampling points 1000, 2000, 5000, 10000 points Window functions Rectangular, Hanning, Hamming, Blackman, Blackman-Harris, Flat-top, Exponential Display format Single, Dual, Nyquist, Running spectrum Averaging function Time axis / frequency axis simple averaging, Exponential averaging, Peak hold (frequency axis), Averaging times (2 to 10000 times) Print functions Same as the MEMORY function (partial print not available) • Voltage drop: Triggering occurs when voltage drops below peak voltage setting (for 50/60 Hz AC power lines only) • Window: Triggering occurs when window defined by upper and lower limit is entered or exited • Period: Rising edge or falling edge cycle of preset voltage value is monitored and triggering occurs when defined cycle range is exceeded • Glitch: Triggering occurs when pulse width from rising or falling edge of preset voltage value is under run • Event setting: Event count is performed for each source, and triggering occurs when a preset count is exceeded • Logic: 1, 0, or ×, Pattern setting Level setting resolution 0.1% of full scale (full scale = 20 divisions) Trigger filter Selectable 0.1 div to 10.0 div 9 steps, or OFF (at MEMORY function) ON (10 ms fixed) or OFF (at RECORDER function) Trigger output Other functions Open collector (5 voltage output, active Low) At Level setting: pulse width (Sampling period × data number after trigger) At Pulse setting: pulse width (2 ms) Trigger priority (OFF/ON), Pre-trigger function for capturing data from before / after trigger event (at MEMORY function), Level display during trigger standby, Start and stop trigger (At RECORDER function), Trigger search function Other functions Waveform judgment function (In MEMORY or FFT function) • Area comparison with reference waveform area for time domain waveform, X-Y waveform, or FFT analysis waveform • Parameter calculated value comparison with reference value • Output: GO/NG decision, Open-collector 5V, *100 msec/div (1 msec sampling) and thereafter allows for evaluation in almost real-time. How is FFT Analysis Performed? Designate a range of the wave- Waveform in the MEM function form stored in the memory func- changes over time in 3-D. tion to perform FFT analysis. It is rendered simultaneously on the screen. D is pl ay t h e s p e c t r u m a s i t FFT analysis V dB Convert data measured with few 1000P calculation points into data with value (sum of the power spec- many points for re-analysis. *Not possible with frequency averaging ON Scale by dB. Input the overall trum) directly as a dB value. 10000P -6.51 dB 93.50 dB Before scaling After scaling 12 ■ Options specifications (sold separately) Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm, approx. 250 g (8.8 oz) Accessories: None ANALOG UNIT 8966 Measurement functions Input connectors Measurement range Measurement resolution Highest sampling rate Measurement accuracy Frequency characteristics Input coupling (Accuracy at 23 ±5°C/73 ±9°F, 20 to 80 % rh after 30 minutes of warm-up time and zero adjustment; accuracy guaranteed for 1 year) Number of channels: 2, for voltage measurement Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF), Max. rated voltage to earth: 300 V AC, DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) 5 mV to 20 V/div, 12 ranges, full scale: 20 div, AC voltage for possible measurement/display using the memory function: 280 V rms, Low-pass filter: 5/50/500 Hz, 5 k/50 k/500 kHz 1/100 of measurement range (using 12-bit A/D conversion) 20 MS/s (simultaneous sampling across 2 channels) ±0.5 % of full scale (with filter 5 Hz, zero position accuracy included) DC to 5 MHz -3 dB, (with AC coupling: 7 Hz to 5 MHz -3dB) AC/DC/GND V DC (the maximum voltage that can be applied across input pins without Max. allowable input 400 damage) Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 204.5 (8.05in) D mm, approx. 240 g (8.5 oz) Accessories: Ferrite clamp × 2 TEMP UNIT 8967 Measurement functions Input connectors (Accuracy at 23 ±5°C/73 ±9°F, 20 to 80 % rh after 30 minutes of warm-up time and zero adjustment; accuracy guaranteed for 1 year) Number of channels: 2, for temperature measurement with thermocouple (voltage measurement not available) Thermocouple input: plug-in connector, Recommended wire diameter: single-wire, 0.14 to 1.5 mm2, braided wire 0.14 to 1.0 mm2 (conductor wire diameter min. 0.18 mm), AWG 26 to 16 Input impedance: min. 5 MΩ (with line fault detection ON/OFF), Max. rated voltage to earth: 300 V AC, DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) 10°C/div (-100 °C to 200 °C), 50°C/div (-200 °C to 1000 °C), 100°C/div (-200°C Temperature measurement range to 2000°C), 3 ranges, full scale: 20 div, Note: Upper and lower limit values Measurement resolution: 1/1000 of measurement range (using 16-bit A/D depend on the thermocouple conversion) K: -200 to 1350°C, J: -200 to 1100°C, E: -200 to 800°C, T: -200 to Thermocouple range 400°C, N: -200 to 1300°C, R: 0 to 1700°C, S: 0 to 1700°C, B: 400 to 1800°C, W (WRe5-26): 0 to 2000°C, (JIS C 1602-1995) (ASTM E-988-96) Reference junction compensation: internal/ external (switchable), Line fault detection ON/OFF possible Data refresh rate Measurement accuracy 3 methods, Fast: 1.2 ms (digital filter OFF), Normal: 100 ms (digital filter 50/60 Hz), Slow: 500 ms (digital filter 10Hz) Thermocouple K, J, E, T, N: ±0.1 % of full scale ±1°C (±0.1 % of full scale ±2°C at -200°C to 0°C), Thermocouple R, S, W: ±0.1 % of full scale ±3.5°C (at 0°C to 400°C or less), ±0.1 % of full scale ±3°C (at 400°C or more) Thermocouple B: ±0.1 % of full scale ±3°C (at 400°C or more), Reference junction compensation accuracy: ±1.5°C (added to measurement accuracy with internal reference junction compensation) Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm, approx. 250 g (8.8 oz) Accessories: None HIGH RESOLUTION UNIT 8968 (Accuracy at 23 ±5°C/73 ±9°F, 20 to 80 % rh after 30 minutes of warm-up time and zero adjustment; accuracy guaranteed for 1 year) Measurement functions Number of channels: 2, for voltage measurement Input connectors Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF), Max. rated voltage to earth: 300 V AC, DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) Measurement range 5 mV to 20 V/div, 12 ranges, full scale: 20 div, AC voltage for possible measurement/display using the memory function: 280 V rms, Low-pass filter: 5/50/500 Hz, 5k/50k Hz Anti-aliasing filter Integrated filter for suppressing aliasing distortion caused by FFT processing (automatic cutoff frequency setting/OFF) Measurement resolution 1/1600 of measurement range (using 16-bit A/D conversion) Highest sampling rate 1 MS/s (simultaneous sampling across 2 channels) Measurement accuracy ±0.3 % of full scale (with filter 5 Hz, zero position accuracy included) Frequency characteristics DC to 100 kHz -3 dB, (with AC coupling: 7 Hz to 100 kHz -3dB) Input coupling Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm, approx. 220 g (7.8 oz) Accessories: Conversion cable 9769 × 2 (cable length 50 cm/1.64 ft) STRAIN UNIT 8969 Measurement functions Number of channels: 2, for distortion measurement (electronic autobalancing, balance adjustment range within ±10000 με) Weidmuller SL 3.5/7/90G (via Conversion Cable 9769, TAJIMI PRC03-12A10Input connectors 7M10.5) Max. rated voltage to earth: 33 Vrms or 70 V DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) Strain gauge converter, Bridge impedance: 120 Ω to 1 kΩ, Bridge voltage: 2 V ±0.05 V, Gauge rate: 2.0 20 με to 1000 με/div, 6 ranges, full scale: 20 div, Measurement range Low-pass filter: 5/10/100 Hz, 1 kHz Measurement 1/1250 of measurement range (using 16-bit A/D conversion) resolution Highest sampling rate 200 kS/s (simultaneous sampling across 2 channels) Suitable transducer Measurement accuracy ±(0.5 % of full scale +4 με) (at 5 Hz filter ON, After auto-balancing) Frequency characteristics DC to 20 kHz +1/-3dB Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm, approx. 250 g (8.8 oz) Accessories: None FREQ UNIT 8970 Measurement functions Input connectors (Accuracy at 23 ±5°C/73 ±9°F, 20 to 80 % rh after 30 minutes of warm-up time; accuracy guaranteed for 1 year) Number of channels: 2, for voltage input based frequency measurement, rotation, power frequency, integration, pulse duty ratio, pulse width Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF), Max. rated voltage to earth: 300 V AC, DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) Frequency mode Range: Between DC to 100 kHz (minimum pulse width 2 μs), 1 Hz/div to 5 kHz/div (full scale= 20 div), 8 settings Accuracy: ±0.1% f.s. (exclude 5 kHz/div), ±0.7% f.s. (at 5 kHz/div) Rotation mode Range: Between 0 to 2 million rotations/minute (minimum pulse width 2 μs), 100 (r/min)/div to 100 k (r/min)/div (full scale= 20 div), 7 settings Accuracy: ±0.1% f.s. (excluding 100 k (r/min)/div), ±0.7% f.s. (at 100 k (r/min)/div) Power frequency mode Range: 50 Hz (40 - 60 Hz), 60 Hz (50 - 70 Hz), 400 Hz (390 - 410 Hz) (full scale= 20 div), 3 settings Accuracy: ±0.03 Hz (exclude 400 Hz range), ±0.1 Hz (400 Hz range) Integration mode Range: 2 k counts/div to 1 M counts/div, 6 settings Accuracy: ±range/2000 Duty ratio mode Range: Between 10 Hz to 100 kHz (minimum pulse width 2 μs), 5%/div (full scale=20 div) Accuracy: ±1% (10 Hz to 10 kHz), ±4% (10 kHz to 100 kHz) Pulse width mode Range: Between 2 μs to 2 sec, 500 μs/div to 100 ms/dv (full scale=20 div) Accuracy: ±0.1% f.s. Measurement resolution 1/2000 of range (Integration mode), 1/500 of range (exclude integration, power frequency mode), 1/100 of range (power frequency mode) Input voltage range and threshold level ±10 V to ±400 V, 6 settings, selectable threshold level at each range Other functions Slope, Level, Hold, Smoothing, Low-pass filter, Switchable DC/AC input coupling, Frequency dividing, Integration over-range keep/return Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm, approx. 250 g (8.8 oz) Accessories: CONVERSION CABLE 9318 × 2 (To connect the current sensor to the 8971) CURRENT UNIT 8971 (Accuracy at 23 ±5°C/73 ±9°F, 20 to 80 % rh after 30 minutes of warm-up time and zero adjustment; accuracy guaranteed for 1 year) Measurement functions Number of channels: 2, Current measurement with optional current sensor, Input connectors Sensor connector (input impedance 1 MΩ, exclusive connector for current sensor Compatible current sensors CT6863, CT6862, 9709, 9279, 9278, 9277, 9272-10 (To connect the Note: Maximum 4 units connectable to main unit via conversion cable the 9318, common GND with recorder) 8971 via conversion cable the 9318) Using 9272-10 (20 A), 9277: 100 mA to 5 A/div (f.s.=20 div, 6 settings) Using CT6862: 200 mA to 10 A/div (f.s.=20 div, 6 settings) Measurement range Using 9272-10 (200 A), 9278, CT6863: 1 A to 50 A/div (f.s.=20 div, 6 settings) Using 9279, 9709: 2 A to 100 A/div (f.s.=20 div, 6 settings) Using 9278, 9279: ±0.85% f.s. Using other sensor: ±0.65% f.s. RMS amplitude accuracy: ±1% f.s. (DC, 30 Hz to 1 kHz), ±3% f.s. (1 kHz to Accuracy AC/DC/GND V DC (the maximum voltage that can be applied across input pins without Max. allowable input 400 damage) (Accuracy at 23 ±5°C/73 ±9°F, 20 to 80 % rh after 30 minutes of warm-up time and auto-balance; accuracy guaranteed for 1 year) 10 kHz) RMS response time: 100 ms (rise time from 0 to 90% of full scale), Crest factor: 2 Frequency characteristics: DC to 100 kHz, ±3 dB (with AC coupling: 7 Hz to 100 kHz) Measurement resolution 1/100 of range (using 12-bit A/D conversion) Highest sampling rate 1 MS/s (simultaneous sampling across 2 channels) Other functions Input coupling: AC/DC/GND, Low-pass filter: 5, 50, 500, 5 k, 50 kHz 13 ■ Options specifications (sold separately) Dimensions and mass: approx. 106 (4.17 in) W × 19.8 (0.78 in) H × 196.5 (7.74 in) D mm, approx. 250 g (8.8 oz) Accessories: None (Accuracy at 23 ±5°C/73 ±9°F, 20 to 80 % rh after 30 minutes of warm-up time and zero adjustment; accuracy guaranteed for 1 year) DC/RMS UNIT 8972 Measurement functions Number of channels: 2, for voltage measurement, DC/RMS selectable Input connectors Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF), Max. rated voltage to earth: 300 V AC, DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) 5 mV to 20 V/div, 12 ranges, full scale: 20 div, AC voltage for possible Measurement range measurement/display using the memory function: 280 V rms, Low-pass filter: 5/50/500 Hz, 5 k/100 kHz Measurement resolution 1/100 of measurement range (using 12-bit A/D conversion) Highest sampling rate 1 MS/s (simultaneous sampling across 2 channels) Measurement accuracy ±0.5 % of full scale (with filter 5 Hz, zero position accuracy included) RMS amplitude accuracy: ±1 % of full scale (DC, 30 Hz to 1 kHz), ±3 % of full scale (1 kHz to 100 kHz), RMS measurement Response time: SLOW 5 s (rise time from 0 to 90% of full scale), MID 800 ms (rise time from 0 to 90% of full scale), FAST 100 ms (rise time from 0 to 90% of full scale), Crest factor: 2 Frequency characteristics DC to 400 kHz -3 dB, (with AC coupling: 7 Hz to 400 kHz -3dB) Input coupling AC/DC/GND Max. allowable input 400 V DC (the maximum voltage that can be applied across input pins without damage) Dimensions and mass: approx. 106 (4.17 in) W × 19.8 (0.78)H × 196.5 (7.74 in)D mm, approx. 260g (8.8 oz) Accessories: None (Accuracy at 23 ±5°C, 20 to 80% rh after 30 minutes of warm-up time and calibration, product and accuracy guaranteed for 1 year) DIGITAL VOLTMETER UNIT MR8990 Measurement functions Number of channels: 2, for DC voltage measurement Banana input connectors (Input resistance: 100 MΩ or higher with 100 mV f.s. to Input connectors 10 V f.s. range, otherwise 10 MΩ) Max. rated voltage to earth: 300 V AC or DC (with input isolated from the main unit, the maximum voltage that can be applied between input channel and chassis, and between input channels without damage) Measurement ranges 100 mV f.s. (5 mV/div) to 1000 V f.s. (50 V/div), 5 ranges, full scale: 20 div Measurement resolution 1/1000000 of measurement range (using 24 bit ΔΣ modulation A/D) Integration time 20 ms ×NPLC (during 50 Hz), 16.67 ms ×NPLC (during 60 Hz) Response time 2 ms +2× integration time or less (rise - f.s. → + f.s., fall + f.s. → - f.s.) Basic measurement ±0.01% rdg. ±0.0025% f.s. (at range of 1000 mV f.s.) accuracy Maximum input voltage 500 V DC (maximum voltage that can be applied between input connectors without damage) Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm, approx. 190 g (6.7 oz) Accessories: None LOGIC UNIT 8973 (accuracy guaranteed for 1 year) Measurement functions Number of channels: 16 channels (4 ch/1 probe connector × 4 connectors) Input connectors Mini DIN connector (for HIOKI logic probes only), Compatible logic probes: 9320-01, 9327, MR9321-01 Cable length and mass: 70 cm (2.30 ft), Output side: 1.5 m (4.92 ft), 170g (6.0 oz) DIFFERENTIAL PROBE P9000 (accuracy guaranteed for 1 year) Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm (0.98 ft), approx. 150 g (5.3 oz) Note: The unit-side plug of the 9320-01 is different from the 9320 LOGIC PROBE 9320 -01/9327 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, accuracy / product guaranteed for 1 year) Detection of voltage signal or relay contact signal for High/Low state recording 4 channels (common ground between unit and channels), digital/contact input, switchable (contact input can detect open-collector signals) Input resistance: 1 MΩ (with digital input, 0 to +5 V) 500 kΩ or more (with digital input, +5 to +50V) Pull-up resistance: 2 kΩ (contact input: internally pulled up to +5 V) P9000-01: For waveform monitor output, Frequency properties: DC to 100 kHz -3 dB P9000-02: Switches between waveform monitor output/AC effective Measurement modes value output Wave mode frequency properties: DC to 100 kHz -3 dB, RMS mode frequency properties: 30 Hz to 10 kHz, Response time: Rise 300 ms, Fall 600 ms Function Division ratio Digital input threshold 1.4 V/ 2.5 V/ 4.0 V 1.4 V: 1.5 kΩ or higher (open) and 500 Ω or lower (short) Contact input 2.5 V: 3.5 kΩ or higher (open) and 1.5 kΩ or lower (short) detection resistance 4.0 V: 25 kΩ or higher (open) and 8 kΩ or lower (short) Switches between 1000:1, 100:1 DC output accuracy ±0.5 % f.s. (f.s. = 1.0 V, division ratio 1000:1), (f.s. = 3.5 V, division ratio 100:1) Effective value measurement accuracy Input resistance/ capacity Maximum input voltage Maximum rated voltage to ground Operating temperature range ±1 % f.s. (30 Hz to less than 1 kHz, sine wave), ±3 % f.s. (1 kHz to 10 kHz, sine wave) H-L: 10.5 MΩ, 5 pF or less (at 100 kHz) Input Response speed 9320-01: 500 ns or lower, 9327: detectable pulse width 100 ns or higher to +50 V DC (the maximum voltage that can be applied across input pins without Max. allowable input 0damage) 1000 V AC, DC 1000 V AC, DC (CAT III) -40°C to 80°C (-40°F to 176°F) Power supply (1) AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 6 VA (including AC adapter), 0.9 VA (main unit only) (2) USB bus power (5 V DC, USB-microB terminal), 0.8 VA (3) External power source 2.7 V to 15 V DC, 1 VA Accessories Instruction manual ×1, Alligator clip ×2, Carrying case ×1 Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft), approx. 320 g (11.3 oz) Note: The unit-side plug of the MR9321-01 is different from the MR9321. LOGIC PROBE MR9321-01 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, accuracy / product guaranteed for 1 year) Function Detection of AC or DC relay drive signal for High/Low state recording Can also be used for power line interruption detection Input 4 channels (isolated between unit and channels), HIGH/LOW range switching Input resistance: 100 kΩ or higher (HIGH range), 30 kΩ or higher (LOW range) Output (H) detection 170 to 250 V AC, ±DC 70 to 250 V (HIGH range) 60 to 150 V AC, ±DC 20 to 150 V (LOW range) Output (L) detection 0 to 30 V AC, ±DC 0 to 43 V (HIGH range) 0 to 10 V AC, ±DC 0 to 15 V (LOW range) Response time Rising edge 1 ms max., falling edge 3 ms max. (with HIGH range at 200 V DC, LOW range at 100 V DC) Vrms (HIGH range), 150 Vrms (LOW range) (the maximum voltage that can Max. allowable input 250 be applied across input pins without damage) 14 System Chart Input modules Main unit *Input cords are not included. Please purchase them separately. *When using 9709 with Current Unit 8971, a total of 7 current probes can be used. ANALOG UNIT 8966 MEMORY HiCORDER MR8827 Note: Main unit MR8827 cannot operate alone. You must install one or more optional input modules in the unit. Order Code MR8827 2 ch, Voltage input, DC to 5 MHz bandwidth Recommended TEMP UNIT 8967 Order Code 8967 HIGH RESOLUTION UNIT 8968 Order Code 8968 STRAIN UNIT 8969 Order Code 8969 Conversion Cable 9769 Order Code 9769 FREQ UNIT 8970 Order Code 8970 2 ch, thermocouple temperature input 2 ch, voltage input, DC to 100 kHz bandwidth 2 ch, strain gauge type converter amp For the 8969(MR8847/8827 series), bundled with the 8969 2 ch, for measurement of frequency, rpm, pulse, etc. Printer options *PRINTER UNIT is a built-in option that must be specified upon order. PRINTER UNIT U8350 Specified upon order. Printing width 200 mm (7.87 inch). Compatible recording paper: Model 9231 RECORDING PAPER 9231 A4 width 216 mm (8.50 in) × 30 m (98.43 ft), 6 rolls/set Storage media Order Code U8350 Order Code 9231 *SSD is a built-in option that must be specified upon order. *The CF card includes a PC card adapter. SSD UNIT U8330 Specified upon order, built-in type, 128 GB Recommended PC CARD 1G 9729 (1 GB) PC CARD 512M 9728 (512 MB) 2 ch, for measuring current using dedicated current sensors, bundled two Conversion cable 9318 * The Current unit 8971 up to four module Order Code 8971 DC/RMS UNIT 8972 Order Code 8972 LOGIC UNIT 8973 Order Code 8973 DIGITAL VOLTMETER UNIT MR8990 Order Code MR8990 2 ch, voltage/DC to 400 kHz, RMS rectifier, DC and 30 to 100 kHz bandwidth 4 terminals, 16 ch * Max. up to two modules of the Logic unit 8973 2ch, high-precision DC V input, 0.1μV resolution, highspeed sampling 500 times/s Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards. (2 GB) CURRENT UNIT 8971 Order Code U8330 *PC Card Precaution PC CARD 2G 9830 Order Code 8966 Order Code 9830 Order Code 9729 Order Code 9728 PC Software WAVE PROCESSOR 9335 Convert data, print and display waveforms LAN COMMUNICATOR 9333 • Waveform data collect function • Remote control with the PC Order Code 9335 Logic signal measurement Order Code 9333 iPad App for MEMORY HiCORDER HMR Terminal Straight Ethernet cable, supplied with straight to cross conversion cable, 5 m (16.41 ft) length Recommended LOGIC PROBE MR9321-01 Recommended . 4-channel type, for voltage/contact Order Code signal ON/OFF detection (response 9327 pulse width 100 ns or more, miniature terminal type) 4 isolated channels, ON/OFF detec- Order Code tion of AC/DC voltage (miniature MR9321-01 terminal type) Download from the App Store Free (exclusively for Apple Inc. iPad) LAN CABLE 9642 LOGIC PROBE 9327 Order Code 9642 LOGIC PROBE 9320-01 4-channel type, for voltage/contact Order Code signal ON/OFF detection (response 9320-01 pulse width 500 ns or more, miniature terminal type) CONVERSION CABLE 9323 *Used for connecting the 9320/9321/ Order Code MR9321 and the 9324 to the Memory 9323 HiCorder with small logic terminal models * This cable is not required for the smallterminal types 9327, 9320-01, 9321-01 and MR9321-01. Case CARRYING CASE (special order) hard trunk type Inquire with your local Hioki distributor. 15 *You can connect up to 4 Current Unit 8971 to the Memory HiCorder main unit, allowing up to 8 current sensors to be used. *There is no limit for connecting current sensors to voltage input analog units. INPUT CORD (A) *Voltage is limited to the specifications of the input modules in use CONNECTION CORD L9790 Recommended Flexible φ 4.1 mm (0.16 in) thin dia., cable allowing for up to 600 V input. 1.8 m (5.91 ft) length Order Code L9790 Up to 20A (High precision) AC/DC CURRENT PROBE CT6841 20 A AC/DC rated current, DC to 1 MHz Order Code response, 20 mm (0.79 in) core dia., 3 m CT6841 (9.84 ft) cord length * The end clip is sold separately. ALLIGATOR CLIP L9790-01 Recommended Red/black set attaches to the ends of the cables L9790 Order Code L9790-01 Red/black set attaches to the ends of the cables L9790 Order Code 9790-02 GRABBER CLIP 9790-02 * When this clip is attached to the end of the L9790, input is limited to CAT II 300 V. Red/black set. CONTACT PIN 9790-03 Red/black set attaches to the ends of the cables L9790 INPUT CORD (B) Order Code 9790-03 *Voltage is limited to the specifications of the input modules in use CONNECTION CORD L9198 φ 5.0 mm (0.20 in) dia., cable allowing for up Order Code to 300 V input. 1.7 m (5.58 ft) length, small L9198 alligator clip CONNECTION CORD L9197 φ 5.0 mm (0.20 in) dia., cable allowing for Order Code up to 600 V input. 1.8 m (5.91 ft) length, a L9197 detachable large alligator clips are bundled GRABBER CLIP 9243 Attaches to the tip of the banana plug cable, Order Code CAT III 1000 V, 196 mm (7.72 in) length 9243 INPUT CORD (C) *Voltage is limited to the specifications of the input modules in use 10:1 PROBE 9665 Note: This probe does not expand the maximum rated voltage above ground of an isolated input. Max. rated voltage to earth is same as for Order Code input module, max. input voltage 1 kV rms 9665 (up to 500 kHz), 1.5 m (4.92 ft) length 100:1 PROBE 9666 Note: This probe does not expand the maximum rated voltage above ground of an isolated input. Max. rated voltage to earth is same as for Order Code input module, max. input voltage 5 kV 9666 peak (up to 1MHz), 1.5 m (4.92 ft) length INPUT CORD (D) *For measuring high voltage. *Voltage to ground is within this product's specifications, and is not affected by connected input modules. Separate power source is also required. DIFFERENTIAL PROBE P9000-01 Recommended (Wave mode only) For the Memory HiCorder series, Order Code input up to 1kV AC/DC P9000-01 DIFFERENTIAL PROBE P9000-02 (Select between WAVE/RMS mode) For the Memory HiCorder series, Order Code P9000-02 input up to 1kV AC/DC AC ADAPTER Z1008 Order Code Z1008 100 to 240 V AC Custom cable Up to 50 A (High precision) AC/DC CURRENT SENSOR CT6862 CAT III 1000 V, 50 A AC/DC rated current, DC to 1 MHz response, φ 24 mm (0.94 in) core dia., 3 m (9.84 ft) cord length Order Code CT6862 Up to 200 A (High precision) AC/DC CURRENT SENSOR CT6863 CAT III 1000 V, 200 A AC/DC rated current, DC to 500 kHz response, φ 24 mm (0.94 in) core dia., 3 m (9.84 ft) cord length Order Code CT6863 AC/DC CURRENT PROBE CT6843 200 A AC/DC rated current, DC to 500kHz Order Code response, 20 mm (0.79 in) core dia., 3 m CT6843 (9.84 ft) cord length CLAMP ON SENSOR 9272-10 CAT III 600 Vrms, 20 A/200 A AC rated Order Code current, 1 Hz to 100 kHz response, φ 46 mm 9272-10 (1.81 in) core dia., 3 m (9.84 ft) cord length Up to 500 A (High precision) AC/DC CURRENT SENSOR 9709 CAT III 1000 V, 500 A AC/DC rated current, Order Code DC to 100 kHz response, φ 36 mm (1.42 in) 9709 core dia., 3 m (9.84 ft) cord length UNIVERSAL CLAMP ON CT 9279-01 600 Vrms insulated wire, 500 A AC/DC rated current, DC to 20 kHz response, φ 40 mm (1.57 in) core dia., 3 m (9.84 ft) cord length, (CE marked) Order Code 9279-01 CLAMP ON PROBE 3273-50 DC to 50 MHz wide band response, mAclass current up to 30 Arms Order Code 3273-50 DC to 100 MHz wide band response, mAclass current up to 30 Arms Order Code 3276 CLAMP ON PROBE 3276 SENSOR UNIT 9555-10 Power supply for the Current Order Code Sensor, used alone 9555-10 CONNECTION CORD L9217 Cord has insulated BNC connec- Order Code tors at both ends, signal output L9217 use, 1.6 m (5.25 ft) length Up to 150 A (High speed) CLAMP ON PROBE 3274 DC to 10 MHz wideband response, mA- Order Code class current up to 150 Arms 3274 Up to 500 A (High speed) CLAMP ON PROBE 3275 DC to 2 MHz wideband response, mA- Order Code class current up to 500 Arms 3275 POWER SUPPLY POWER SUPPLY 3272 For the 3270 series, single Order Code sensor connectable (2 units pos3272 sible depending on conditions) POWER SUPPLY 3269 For the 3270 series, connect up to four sensors Order Code 3269 100 A to 5000 A (Medium speed) Bus powered USB cable CLAMP ON AC/DC SENSOR CT9691-90 For power supply from a USB-A terminal DC to 10kHz (-3dB), 100A, Order Code Output 0.1 V/f.s. CT9691-90 USB(A)- Micro B cable For power supply via USB Micro B terminal from a USB-A terminal CLAMP ON AC/DC SENSOR CT9692-90 3-prong cable DC to 20kHz (-3dB), 200A, Order Code Output 0.2 V/f.s. CT9692-90 AC adapter output terminal split into 3 CLAMP ON AC/DC SENSOR CT9693-90 Other options for Input DC to 15kHz (-3dB), 2000A, Order Code Output 0.2 V/f.s. CT9693-90 CONNECTION CORD L9217 FLEXIBLE CLAMP ON Order Code SENSOR CT9667 Cord has insulated BNC connectors Order Code at both ends, signal output use, 1.6 L9217 m (5.25 ft) length Receiving side banana, output BNC terminal using Current Unit 8971 Up to 30 A (High speed) *For P9000. Inquire with your Hioki distributor. CONVERSION ADAPTER 9199 POWER SUPPLY *Not necessary when 10Hz to 20kHz (±3dB), AC 5000A/500A, Output AC 500mV/f.s., φ 254 mm (10.0 in) core dia. Order Code 9199 CT9667 LEAK CURRENT *For commercial power lines, 50/60 Hz INPUT CORD (E) CLAMP ON LEAK HiTESTER 3283 *For the MR8990 *Voltage is limited to the specifications of the input modules in use TEST LEAD L2200 Cable length: 70 cm, tips interchangeable Order Code with a pin lead or alligator clip, maximum L2200 input voltage: CAT IV 600V, CAT III 1000V Temperature sensor *For reference only. purchase locally. Thermocouple Please 10mA range / 10μA resolution to 200A range, moniter / analog output 1V f.s. 500 A to 1000 A *For commercial power lines, 50/60Hz (separate power supply not required) CLAMP ON PROBE 9018-50 Excellent phase characteristics, Input Order Code from 10 to 500 A, 40 Hz to 3 kHz for 9018-50 0.2 V AC output, BNC terminal CLAMP ON PROBE 9132-50 Input from 20 to 1000 A, 40 Hz Order Code to 1 kHz for 0.2 V AC output, 9132-50 BNC terminal OUTPUT CORD 9094 Order Code 3283 3.5mm (0.14in) dia. mini plug to banana , 1.5m (4.92ft) length Order Code 9094 Receiving side banana, output BNC terminal Order Code 9199 CONVERSION ADAPTER 9199 AC ADAPTER 9445-02 For USA, 100 to 240 V AC, 9 V/ 1 A Order Code 9445-02 AC ADAPTER 9445-03 For EU 100 to 240 V AC, 9 V/ 1 A 9445-03 Evolution Will Never Cease. Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI (Shanghai) SALES & TRADING CO., LTD. TEL +86-21-63910090 FAX +86-21-63910360 http://www.hioki.cn / E-mail: [email protected] DISTRIBUTED BY HIOKI INDIA PRIVATE LIMITED TEL +91-124-6590210 FAX +91-124-6460113 HEADQUARTERS E-mail: [email protected] 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 FAX +81-268-28-0568 HIOKI SINGAPORE PTE. LTD. http://www.hioki.com / E-mail: [email protected] TEL +65-6634-7677 FAX +65-6634-7477 E-mail: [email protected] HIOKI USA CORPORATION HIOKI KOREA CO., LTD. TEL +1-609-409-9109 FAX +1-609-409-9108 TEL +82-42-936-1281 FAX +82-42-936-1284 http://www.hiokiusa.com / E-mail: [email protected] E-mail: [email protected] All information correct as of Jan. 30, 2015. All specifications are subject to change without notice. MR8827E1-51E Printed in Japan