DC tangential blower QG030-148/14 forward-curved ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Str. 1 D-78112 St. Georgen Phone +49 (0) 7724 81-0 Fax +49 (0) 7724 81-1309 [email protected] www.ebmpapst.com Nominal data Type QG030-148/14 Nominal voltage VDC 24 Nominal voltage range VDC 16 .. 28 Power consumption W 6.2 Min. ambient temperature °C -20 Max. ambient temperature °C 60 Air flow m3/h 75 Sound power level B 5.7 Sound pressure level dB(A) 49 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change ENU (Web) · Approved 2016-06-22 · Page 1 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com DC tangential blower QG030-148/14 forward-curved Technical description Weight 0.235 kg Impeller material Aluminum Housing material Aluminum, housing side parts made of plastic. Direction of rotation Clockwise, viewed toward rotor Storage Motor with ball bearing system. Impeller retaining plate with sleeve bearing. Service life L10 at 40 °C 30000 h Service life L10 at maximum temperature 20000 h Cable With leads AWG 24, TR 64 Motor protection Protection against reverse polarity and blocked rotor. Locked-rotor protection Locked-rotor and overload protection Approval VDE, CSA, UL, CE ENU (Web) · Approved 2016-06-22 · Page 2 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com QG030-148/14 DC tangential blower forward-curved Product drawing 148 203,4 +1,5 Cutout for squarenut M3 DIN 562-flat (6x) ENU (Web) · Approved 2016-06-22 · Page 3 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com DC tangential blower QG030-148/14 forward-curved [in H2O] Pa Curves 40 0,15 50 0,10 30 10 0,05 20 0 15 20 30 40 45 60 80 60 100 75 120 CFM m³/h ENU (Web) · Approved 2016-06-22 · Page 4 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com