μModule Regulator with READ/WRITE Telemetry

µModule Regulator with
READ/WRITE Telemetry
Dual 13A, Single 26A µModule Regulator for up to
100A Output with Digital Power System Management
Take control of your power. Digital control and monitoring of system power with the LTM®4676 (16mm x 16mm x 5.01mm
BGA) eliminates PCB layout and circuit changes. This accelerates system characterization, optimization and data
mining during prototyping, deployment and field operation. With the LTM4676’s serial digital interface, system
designers and remote operators can command and supervise system power conditions and consumption.
Features
• ±1% Maximum Total DC Output Error
(over Temperature)
• ±2.5% Current Read Back Accuracy
at 10A (over Temperature), without
Sense Resistors
Excellent Current Sharing and
Thermal Balance
(12VIN, 1.0VOUT, 100A, 300 LFM)
Info
www.linear.com/product/LTM4676
1-800-4-LINEAR
• Precision 16-bit Δ∑ ADC
Readable Data:
• Temperature, VOUT, IIN, IOUT
• Peak Values, Faults and Warnings
• Fault Log Record
Writable Data:
• VOUT, IOUT, Sequencing and Margining
• Soft-Start/Stop Ramps
LTM4676 Ad.indd 1
USB
Cable
USB I2C/PMBus
Dongle DC1613A
12-Pin
Connector
LTM4676
Demo Board
VOUT0
Load
, LT, LTC, LTM, Linear Technology, the Linear logo and µModule
are registered trademarks of Linear Technology Corporation.
All other trademarks are the property of their respective owners.