DC axial compact fan 4114 N/2H7P ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Str. 1 D-78112 St. Georgen Phone +49 (0) 7724 81-0 Fax +49 (0) 7724 81-1309 [email protected] www.ebmpapst.com Nominal data Type 4114 N/2H7P Nominal voltage VDC 24 Nominal voltage range VDC 16 .. 30 Speed (rpm) min-1 9500 Power consumption W 90 Min. ambient temperature °C -20 Max. ambient temperature °C 75 Air flow m3/h 500 Sound power level B 8.5 Sound pressure level dB(A) 76 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change ENU (Web) · Approved 2016-06-22 · Page 1 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com DC axial compact fan 4114 N/2H7P Technical description General description Power consumption when wide open; these values may be considerably higher at the operating point. Impeller material Glass-fiber reinforced PA plastic Weight 0.425 kg Dimensions 119 x 119 x 38 mm Housing material Die-cast aluminum Airflow direction Intake over struts Direction of rotation Clockwise, viewed toward rotor Storage Ball bearing Service life L10 at 40 °C 57500 h Service life L10 at maximum temperature 25000 h Cable Leads AWG 20, sensor and control leads AWG 22, UL 1007, TR 64, stripped and tinplated. Motor protection Protection against reverse polarity and blocked rotor. Option Other inputs and outputs ENU (Web) · Approved 2016-06-22 · Page 2 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com 4114 N/2H7P DC axial compact fan Product drawing ENU (Web) · Approved 2016-06-22 · Page 3 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com DC axial compact fan 4114 N/2H7P 2,4 400 1,6 200 D pf S 600 0,8 800 (in H ² O) 1000 3,2 Pa Curves: Air performance 0 • VS 50 100 100 200 150 200 300 250 400 300 CFM 500 m³/h ENU (Web) · Approved 2016-06-22 · Page 4 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com