DC axial fan 3212JH3 ENU

DC axial compact fan
3212 JH3
ebm-papst St. Georgen GmbH & Co. KG
Hermann-Papst-Str. 1
D-78112 St. Georgen
Phone +49 (0) 7724 81-0
Fax +49 (0) 7724 81-1309
[email protected]
www.ebmpapst.com
Nominal data
Type
3212 JH3
Nominal voltage
VDC
12
Nominal voltage range
VDC
6 .. 13.8
Speed (rpm)
min-1
11000
Power consumption
W
31
Min. ambient temperature
°C
-20
Max. ambient temperature
°C
70
Air flow
m3/h
237
Sound power level
B
7.8
Sound pressure level
dB(A)
69
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
ENU (Web) · Approved 2016-06-22 · Page 1 / 4
ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] ·
www.ebmpapst.com
DC axial compact fan
3212 JH3
Technical description
General description
* Power consumption when wide open; these values may be considerably higher at the
operating point.
Housing material
Glass-fiber reinforced PBT plastic
Impeller material
Glass-fiber reinforced PA plastic
Weight
0.280 kg
Dimensions
92 x 92 x 38 mm
Airflow direction
Exhaust over struts
Direction of rotation
Clockwise, viewed toward rotor
Storage
Ball bearing
Service life L10 at 40 °C
65000 h
Service life L10 at maximum
temperature
32500 h
Cable
Leads AWG 22, TR 64
Motor protection
Protection against reverse polarity and blocked rotor.
Approval
VDE, CSA, UL
Option
Speed signal
ENU (Web) · Approved 2016-06-22 · Page 2 / 4
ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] ·
www.ebmpapst.com
3212 JH3
DC axial compact fan
Product drawing
ENU (Web) · Approved 2016-06-22 · Page 3 / 4
ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] ·
www.ebmpapst.com
DC axial compact fan
3212 JH3
(in H ² O)
Pa
Curves: Air performance
0,8
100
D pf S
200
0,4
300
1,2
400
1,6
500
0
•
VS
25
50
50
100
75
100
150
125
200
150 CFM
250
m³/h
ENU (Web) · Approved 2016-06-22 · Page 4 / 4
ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] ·