CPLL58 1800 1860

M
ICROWAVE
A Division of Crystek Corporation
CPLL58-1800-1860
0.582" × 0.800" SMD
Features
1.800 GHz - 1.860 GHz Range in Bands
Standard 3 Wire Interface
Small layout 0.582" × 0.8"
Applications
Digital Radio Equipment
Fixed Wireless Access
Satellite Communications Systems
Base Stations
Personal Communications Systems
Portable Radios
Test Instruments
Wireless Infrastructure
The CPLL58 is a complete PLL/Synthesizer needing only an external frequency reference and supply
voltages for the internal PLL (phase lock loop) and VCO (voltage controlled oscillator). The Crystek
CPLL58 is programmed using a standard three line interface (Data, Clock and Load Enable).
The CPLL58 family has been initially released to cover 1 GHz to 5 GHz in bands. It is housed in a
compact 0.582-in. × 0.8-in. × 0.15-in. SMD package which saves board space. Typical phase noise at
4 GHz is -90 dBc/Hz at 10 kHz offset with 0 dBm minimum output power.
Rev D
Page 1 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
CPLL58-1800-1860
0.582" × 0.800" SMD
PERFORMANCE SPECIFICATION
MIN
Frequency Range:
1.800
TYP
MAX
UNITS
1.860
GHz
Step Size:
10
kHz
Settling Time, to within ± 1kHz (Freq. step < 25MHz):
1
msec
Output Power:
0
+3.0
+6.0
dBm
@1kHz offset
-82
-80
dBc/Hz
@10kHz offset
-103
-98
dBc/Hz
@100kHz offset
-127
-122
dBc/Hz
@1MHz offset
-147
-142
dBc/Hz
Output Phase Noise: (See Plot Below)
Power Supply:
V1=VCO Supply
4.75
5.0
5.25
Volts
V2=PLL Supply
2.7
3.0
3.3
Volts
Supply Current:
I1=VCO Input Current
20
mA
I2=PLL Input Current
15
mA
Reference Feedthru
-80
-70
dBc
2nd
-20
-15
dBc
Reference Frequency
10
nd
Harmonic Suppression (2
Harmonic):
Input Reference Level
0.8
Input Impedance
RF Output Impedance
Operating Temperature Range:
-40
MHz
V2
Vp-p
100k
Ohm
50
Ohm
+85
°C
0.6
Volts
Logic Inputs (Clock, Data, and LE):
Input “High” Voltage
1.4
Input “Low” Voltage
Locked Detector (LD):
Locked
Un-Locked
Rev D
1.4
Volts
0.4
Volts
Page 2 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
Rev D
CPLL58-1800-1860
0.582" × 0.800" SMD
Page 3 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
0.582" × 0.800" SMD
GND
V1
GND
GND
GND
0.411
GND
GND
LE
0.582
LE
= Load Enable, CMOS Input
DATA = Serial Data Input
CLK = Clock
LD
= Lock Detect
REF = Reference Input
V1
= Analog Supply Input (VCO)
V2
= Digital Supply Input (PLL)
RF
= RF Output
RF
GND
0.331
GND
GND
GND
LD
GND
0.251
CLK
0.171
DATA
CRYSTEK
CPLL58
1800-1860
YYWW
REF
0.00
GND
0.00
V2 [Pin1]
BOTTOM VIEW
0.200
0.280
0.360
0.440
0.520
0.600
0.800
TOP VIEW
CPLL58-1800-1860
TOP ORIENTATION MARK
0.052
0.150
0.000
0.052
0.000
0.000
Pad Detail
RECOMMENDED REFLOW SOLDERING PROFILE
Ramp-Up
3°C/Sec Max.
TEMPERATURE
260°C
Critical Temperature Zone
Ramp-Down
6°C/Sec.
217°C
200°C
150°C
Preheat
180 Secs. Max.
90 Secs. Max.
8 Minutes Max.
260°C for
10 Secs. Max.
Rev D
Page 4 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
CPLL58-1800-1860
0.582" × 0.800" SMD
ENVIRONMENTAL COMPLIANCE
Parameter
Conditions
Mechanical Shock
MIL-STD-883, Method 2002
Mechanical Vibration
MIL-STD-883, Method 2007
Solderability
MIL-STD-883, Method 1014
Resistance to Solvents
MIL-STD-883, Method 2016
Timing Characteristics for CPLL58-1800-1860
Parameter1
Limit at TMIN to TMAX (B Version)
Unit
t1
t2
t3
t4
t5
t6
t7
20
10
10
25
25
10
20
ns min
ns min
ns min
ns min
ns min
ns min
ns min
1
Test Conditions/Comments
LE setup time
DATA to CLOCK setup time
DATA to CLOCK hold time
CLOCK high duration
CLOCK low duration
CLOCK to LE setup time
LE pulse width
Guaranteed by design, but not production tested.
t4
t5
CLOCK
t1
DATA
DB23 (MSB)
t2
t3
DB22
DB2
DB1(CONTROL
BIT C2)
DB0(LSB)
(CONTROL BIT C1)
t7
LE
t6
LE
Figure 1. Timing Diagram
Rev D
Page 5 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
CPLL58-1800-1860
0.582" × 0.800" SMD
Register Summary
FAST-LOCK
N-DIVIDER REG
9-BIT RF N VALUE
CONTROL
BITS
12-BIT RF FRAC VALUE
DB21
DB20
DB19
DB18
DB17
DB16
DB15
DB14
DB13
DB12
DB11
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
FL1
N9
N8
N7
N6
N5
N4
N3
N2
N1
F12
F11
F10
F9
F8
F7
F6
F5
F4
F3
F2
F1
C2(0)
C1(0)
DB23
DB22
DB21
DB20
DB19
DB18
DB17
DB16
DB15
DB14
DB13
DB12
DB11
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
P3
M3
M2
M1
P2
P1
R4
R3
R2
R1
M12
M11
M10
M9
M8
M7
M6
M5
M4
M3
M2
M1
C2(0)
C1(1)
CONTROL
BITS
RF POWERDOWN
RF CHARGE
PUMP THREESTATE
RF COUNTER
RESET
DB15
DB14
DB13
DB12
DB11
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
0
0
U6
CP3
CP2
CP1
CP0
U5
U4
U3
U2
U1
C2(1)
C1(0)
CHARGE PUMP
CURRENT SETTING
RESERVED
RESERVED
NOISE AND SPUR MODE
NOISE AND
SPUR MODE
LOCK DETECT
PRECISION
12-BIT INTERPOLATOR MODULUS VALUE/FAST-LOCK TIMER
PHASE
DETECTOR
POLARITY
4-BIT R VALUE
CP/2
MUXOUT
REFIN
DOUBLER
LOAD
CONTROL
PRESCALER
DB22
RESERVED
DB23
RESERVED
CONTROL
BITS
CONTROL
BITS
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
T9
T8
T7
T6
T5
T4
T3
T2
T1
C2(1)
C1(1)
Specifications subject to change without notice.
Rev D
Page 6 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
CPLL58-1800-1860
0.582" × 0.800" SMD
FAST-LOCK
N-Divider Register Map
9-BIT RF N VALUE (INT)
CONTROL
BITS
12-BIT FRAC VALUE (FRAC)
DB23
DB22
DB21
DB20
DB19
DB18
DB17
DB16
DB15
DB14
DB13
DB12
DB11
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
FL1
N9
N8
N7
N6
N5
N4
N3
N2
N1
F12
F11
F10
F9
F8
F7
F6
F5
F4
F3
F2
F1
C2(0)
C1(0)
F12
F11
F10
0
0
0
0
.
.
.
1
1
1
1
0
0
0
0
.
.
.
1
1
1
1
0
0
0
0
.
.
.
1
1
1
1
……..
……..
……..
……..
……..
……..
……..
……..
……..
……..
……..
N9
N8
N7
N6
N5
N4
N3
N2
N1
INTERGER
VALUE (INT)
0
0
0
0
.
.
.
1
1
1
0
0
0
0
.
.
.
1
1
1
0
0
0
0
.
.
.
1
1
1
0
1
1
1
.
.
.
1
1
1
1
0
0
0
.
.
.
1
1
1
1
0
0
0
.
.
.
1
1
1
1
0
0
0
.
.
.
1
1
1
1
0
1
1
.
.
.
0
1
1
0
1
0
1
.
.
.
1
0
1
31
32
33
34
.
.
.
509
510
511
FL1
FAST-LOCK
0
1
NORMAL OPERATION
FAST-LOCK ENABLED
F3
F2
F1
FRACTIONAL
VALUE (FRAC)
0
0
0
0
.
.
.
1
1
1
1
0
0
1
1
.
.
.
0
0
1
1
0
1
0
1
.
.
.
0
1
0
1
0
1
2
3
.
.
.
4092
4093
4094
4095
Specifications subject to change without notice.
Rev D
Page 7 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
CPLL58-1800-1860
0.582" × 0.800" SMD
PRESCALER
DB23
DB22
DB21
DB20
DB19
DB18
DB17
DB16
DB15
DB14
DB13
DB12
DB11
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
P3
M3
M2
M1
0
P1
R4
R3
R2
R1
M12
M11
M10
M9
M8
M7
M6
M5
M4
M3
M2
M1
C2(0)
C1(0)
LOAD
CONTROL
RESERVED
R-Divider Register Map
MUXOUT
4-BIT R VALUE
P3
LOAD CONTROL
P1
PRESCALER
M12
M11
M10
0
1
NORMAL OPERATION
LOAD FAST LOCK TIMER
0
1
4/5
8/9
0
0
0
.
.
.
1
1
1
1
0
0
0
.
.
.
1
1
1
1
0
0
0
.
.
.
1
1
1
1
R4
R3
R2
R1
R VALUE
DIVIDE RATIO
0
0
0
0
.
.
.
1
1
1
1
0
0
0
1
.
.
.
1
1
1
1
0
1
1
0
.
.
.
0
0
1
1
1
0
1
0
.
.
.
0
1
0
1
1
2
3
4
.
.
.
12
13
14
15
M3
M2
M1
MUXOUT
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
THREE-STATE OUTPUT
DIGITAL LOCK DETECT
N DIVIDER OUTPUT
LOGIC HIGH
R DIVIDER OUTPUT
ANALOG LOCK DETECT
FASTLOCK SWITCH
LOGIC LOW
CONTROL
BITS
12-BIT INTERPOLATOR MODULUS VALUE (MOD)/FAST-LOCK TIMER
……..
……..
……..
……..
……..
……..
……..
……..
……..
……..
M3
M2
M1
INTERPOLATOR MODULUS
VALUE (MOD)
0
0
1
.
.
.
1
1
1
1
1
1
0
.
.
.
0
0
1
1
0
1
0
.
.
.
0
1
0
1
2
3
4
.
.
.
4092
4093
4094
4095
Specifications subject to change without notice.
Rev D
Page 8 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
CPLL58-1800-1860
0.582" × 0.800" SMD
REFIN
DOUBLER
CP/2
PHASE
DETECTOR
POLARITY
LOCK DETECT
PRECISION
RF POWERDOWN
RF CHARGE
PUMP THREESTATE
RF COUNTER
RESET
Control Register Map
DB15
DB14
DB13
DB12
DB11
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
S4
S3
S2
S1
U6
CP3
CP2
CP1
CP0
U5
U4
U3
U2
U1
C2(1)
C1(0)
RESYNC
CHARGE PUMP
CURRENT SETTING
CONTROL
BITS
U6
REFIN
DOUBLER
U1
COUNTER
RESET
0
1
DISABLED
ENABLED
0
1
DISABLED
ENABLED
U2
RF CHARGE PUMP THREE- STATE
0
1
DISABLED
THREE-STATE
U3
RF POWER-DOWN
0
1
NORMAL OPERATION
POWER-DOWN
S4
S3
S2
S1
RESYNC
U4
LOCK DETECT PRECISION
0
0
0
.
.
.
1
1
1
0
0
0
.
.
.
1
1
1
0
1
1
.
.
.
0
1
1
1
0
1
.
.
.
1
0
1
1
2
3
.
.
.
13
14
15
0
1
24 PFD CYCLES
40 PFD CYCLES
2.7kΩ
ICP (mA)
5.1kΩ
10kΩ
0
1
0
1
0
1
0
1
1.18
2.46
3.54
4.72
5.90
7.08
8.26
9.45
0.63
1.25
1.88
2.50
3.13
3.75
4.38
5.00
0.32
0.64
0.96
1.28
1.59
1.92
2.23
2.55
0
1
0
1
0
1
0
1
0.59
1.23
1.77
2.36
2.95
3.54
4.13
4.73
0.31
0.63
0.94
1.25
1.57
1.88
2.19
2.50
0.16
0.32
0.48
0.64
0.80
0.96
1.12
1.28
CP3
CP2
CP1
CP0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
U5
PHASE DETECTOR POLARITY
0
1
NEGATIVE
POSITIVE
Specifications subject to change without notice.
Rev D
Page 9 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
CPLL58-1800-1860
0.582" × 0.800" SMD
NOISE AND SPUR MODE
NOISE AND
SPUR MODE
RESERVED
Noise and Spur Register
RESERVED
CONTROL
BITS
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
T9
T8
T7
T6
T5
T4
T3
T2
T1
C2(1)
C1(1)
DB10, DB5, DB4, DB3
0
RESERVED
RESERVED
THESE BITS MUST BE SET TO 0 FOR
NORMAL OPERATION.
DB9, DB8, DB7, DB6, DB2
NOISE AND SPUR SETTING
00000
11100
11111
LOWEST SPUR MODE
LOW NOISE AND SPUR MODE
LOWEST NOISE MODE
Programming Crystek p/n: CPLL58-1800-1860
TBD
Specifications subject to change without notice.
Rev D
Page 10 of 10
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061