DC axial compact fan 612 NMLE ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Str. 1 D-78112 St. Georgen Phone +49 (0) 7724 81-0 Fax +49 (0) 7724 81-1309 [email protected] www.ebmpapst.com Nominal data Type 612 NMLE Nominal voltage VDC 12 Nominal voltage range VDC 8 .. 15 Speed (rpm) min-1 3000 Power consumption W 0.4 Min. ambient temperature °C -20 Max. ambient temperature °C 85 Air flow m3/h 25 Sound power level B 3.9 Sound pressure level dB(A) 19 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change ENU (Web) · Approved 2016-06-22 · Page 1 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com DC axial compact fan 612 NMLE Technical description Housing material Glass-fiber reinforced PBT plastic Impeller material Glass-fiber reinforced PA plastic Weight 0.066 kg Dimensions 60 x 60 x 25 mm Airflow direction Exhaust over struts Direction of rotation Clockwise, viewed toward rotor Storage Ball bearing Service life L10 at 40 °C 80000 h Service life L10 at maximum temperature 27500 h Cable Leads AWG 22, TR 64, stripped and tin-plated. Motor protection Protection against reverse polarity and blocked rotor. Locked-rotor protection With electronic locked-rotor and overload protection Approval VDE, CSA, UL, CE Option Possible custom designs: Speed signal Go / No-go alarm Moisture protection Degree of protection: IP54 / IP68 ENU (Web) · Approved 2016-06-22 · Page 2 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com 612 NMLE DC axial compact fan Product drawing ENU (Web) · Approved 2016-06-22 · Page 3 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com DC axial compact fan 612 NMLE (in H ² O) 30 0,100 Pa Curves: Air performance D pf S 5 0,050 10 0,025 15 0,075 20 0 • VS 5 5 10 10 15 15 20 25 CFM m³/h ENU (Web) · Approved 2016-06-22 · Page 4 / 4 ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] · www.ebmpapst.com