AC centrifugal fan RG901850 ENU

AC centrifugal compact fan
RG 90-18/50
single-intake
ebm-papst St. Georgen GmbH & Co. KG
Hermann-Papst-Str. 1
D-78112 St. Georgen
Phone +49 (0) 7724 81-0
Fax +49 (0) 7724 81-1309
[email protected]
www.ebmpapst.com
Nominal data
Type
RG 90-18/50
Phase
1~
Nominal voltage
VAC
230
Frequency
Hz
50
Speed (rpm)
min-1
2200
Power consumption
W
22.0
Min. ambient temperature
°C
-30
Max. ambient temperature
°C
60
Air flow
m3/h
54
Sound power level
B
5.8
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
ENU (Web) · Approved 2016-06-22 · Page 1 / 4
ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] ·
www.ebmpapst.com
AC centrifugal compact fan
RG 90-18/50
single-intake
Technical description
General description
Forward-curved impeller
Housing material
Scroll housing made of glass-fiber reinforced PBT plastic, housing base made of sheet
steel
Weight
0.560 kg
Dimensions
135 x 135 x 38 mm
Impeller material
Glass-fiber reinforced PA plastic
Airflow direction
Radial: discharge through window in housing
Direction of rotation
Clockwise, viewed toward rotor
Storage
Sintec sleeve bearing
Service life L10 at 40 °C
35000 h
Service life L10 at maximum
temperature
22500 h
Cable
2 leads AWG 22
Motor protection
Protected from overload by impedance protection
Approval
VDE, CSA, UL, CE
ENU (Web) · Approved 2016-06-22 · Page 2 / 4
ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] ·
www.ebmpapst.com
RG 90-18/50
AC centrifugal compact fan
single-intake
Product drawing
ENU (Web) · Approved 2016-06-22 · Page 3 / 4
ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] ·
www.ebmpapst.com
AC centrifugal compact fan
RG 90-18/50
single-intake
(in H ² O)
Pa
Curves: Air performance
80
0,3
100
0,2
60
∆ pf ä
20
0,1
40
0
•
Vä
5
10
10
15
20
20
30
25
40
30
CFM
50
m³/h
ENU (Web) · Approved 2016-06-22 · Page 4 / 4
ebm-papst St. Georgen GmbH & Co. KG · Hermann-Papst-Str. 1 · D-78112 St. Georgen · Phone +49 (0) 7724 81-0 · Fax +49 (0) 7724 81-1309 · [email protected] ·