DATASHEET

IGNS
W DES
E
N
R
O
F
RT
ENDED ACEMENT PA
M
M
O
C
L
D REP
N OT R E
MENDE
3
RECOM
ISL2902
Data Sheet
November 11, 2011
Light-to-Digital Output Sensor with High
Sensitivity, Gain Selection, and I2C
Interface
The ISL29010 is an integrated light sensor with I2C
interface. It has an internal signed15-bit integrating type
ADC designed based on the charge-balancing conversion
technique. This ADC is capable of rejecting 50Hz and 60Hz
flicker caused by artificial light sources. The lux range select
feature allows the user to program the lux range for
optimized counts/lux.
In normal operation, power consumption is typically 250µA.
Furthermore, a power-down mode can be controlled by
software via the I2C interface, reducing power consumption
to less than 1µA.
Designed to operate on supplies from 2.5V to 3.3V, the
ISL29010 is specified for operation over the -40°C to +85°C
ambient temperature range.
ISL29010
FN6414.1
Features
• Range select via I2C
- Range 1 = 0 lux to 2,000 lux
- Range 2 = 0 lux to 8,000 lux
- Range 3 = 0 lux to 32,000 lux
- Range 4 = 0 lux to 128,000 lux
• Human eye response (540nm peak sensitivity)
• Temperature compensated
• Signed 15-bit resolution
• Adjustable resolution: up to 20 counts per lux
• 1 bit I2C address selection
• Simple output code, directly proportional to lux
• IR + UV rejection
• 50Hz/60Hz rejection
• 2.5V to 3.3V supply
Ordering Information
6 Ld ODFN
PKG.
DWG. #
L6.2x2.1
Evaluation Board
• Pb-free (RoHS compliant)
• Operating temperature range: -40°C to +85°C
Applications
NOTES:
1. Please refer to TB347 for details on reel specifications.
2. These Intersil Pb-free plastic packaged products employ special
Pb-free material sets; molding compounds/die attach materials
and 100% matte tin plate - e3 termination finish, which is RoHS
compliant and compatible with both SnPb and Pb-free soldering
operations. Intersil Pb-free products are MSL classified at
Pb-free peak reflow temperatures that meet or exceed the
Pb-free requirements of IPC/JEDEC J STD-020.
• Industrial and medical light sensing
Block Diagram
VDD
1
PHOTODIODE
ARRAY
MODE
3. For Moisture Sensitivity Level (MSL), please see device
information page for ISL29010. For more information on MSL
please see tech brief TB477.
• Display and keypad backlight dimming for
- Mobile Devices: Smart phone, PDA, and GPS
- Computing devices: Notebook PC, UMPC web pod
- Consumer devices: LCD-TV, digital picture frame, and
digital cameras
Pinout
ISL29010
(6 LD ODFN)
TOP VIEW
LIGHT
DATA
PROCESS
VDD 1
6 SDA
GND 2
5 SCL
IREF
EXT
TIMING
DATA
REGISTER
I2C
5 SCL
6 SDA
216
COUNTER
3
REXT
1
INTEGRATING
ADC
COMMAND
REGISTER
FOSC
4 A0
REXT 3
SHDN
-40 to +85
PACKAGE
(Pb-Free)
INT TIME
ISL29010IROZ-T7
ISL29010IROZ-EVALZ
• 6 Ld ODFN (2.1mmx2mm)
TEMP.
RANGE (°C)
GAIN/RANGE
PART NUMBER
(Notes 1, 2, 3)
2
GND
ISL29010
4
A0
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Copyright Intersil Americas LLC 2008, 2011. All Rights Reserved
I2C Bus is a registered trademark owned by NXP Semiconductors Netherlands, B.V
Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries.
All other trademarks mentioned are the property of their respective owners.
ISL29010
Absolute Maximum Ratings (TA = +25°C)
Thermal Information
VDD Supply Voltage between VDD and GND . . . . . . . . . . . . . 3.6V
I2C Bus Pin Voltage (SCL, SDA) . . . . . . . . . . . . . . . . . -0.2V to 5.5V
I2C Bus Pin Current (SCL, SDA) . . . . . . . . . . . . . . . . . . . . . . <10mA
A0, REXT Pin Voltage . . . . . . . . . . . . . . . . . . . . . . . . . -0.2V to VDD
ESD Rating
Human Body Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2kV
Machine Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200V
Thermal Resistance (Typical Note 4)
JA (°C/W)
6 Ld ODFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
88
Maximum Die Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . +90°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +100°C
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Pb-free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTE:
4. JA is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach” features. See
Tech Brief TB379.
IMPORTANT NOTE: All parameters having Min/Max specifications are guaranteed. Typical values are for information purposes only. Unless otherwise noted, all tests
are at the specified temperature and are pulsed tests, therefore: TJ = TC = TA
Electrical Specifications
PARAMETER
VDD = 3V, TA = +25°C, REXT = 100k, unless otherwise specified, Internal Timing Mode operation (See
“Principles of Operation” on page 3).
DESCRIPTION
CONDITION
MIN
(Note 7)
TYP
MAX
(Note 7)
0.5k to 10k
UNIT
Ee
Detectable Input Light Intensity
VDD
Power Supply Range
IDD
Supply Current
IDD1
Supply Current Disabled
Software disabled
fOSC1
Internal Oscillator Frequency
Gain/Range = 1 or 2
fOSC2
Internal Oscillator Frequency
Gain/Range = 3 or 4
fI2C
I2C Clock Rate Range
DATA0
Dark ADC Code
DATA1
Full-Scale ADC Code
DATA2
Light Count Output
E = 300 lux, fluorescent light, Gain/Range = 1
(Note 5)
DATA3
Light Count Output
E = 300 lux, fluorescent light, Gain/Range = 2
(Note 5)
1100
Counts
DATA4
Light Count Output
E = 300 lux, fluorescent light, Gain/Range = 3
(Note 5)
275
Counts
DATA5
Light Count Output
E = 300 lux, fluorescent light, Gain/Range = 4
(Note 5)
69
Counts
VREF
Voltage of REXT Pin
VTL
SCL ,SDA and A0 Threshold LO
(Note 6)
1.05
V
VTH
SCL ,SDA and A0 Threshold HI
(Note 6)
1.95
V
ISDA
SDA Current Sinking Capability
5
mA
2.50
lux
3.30
V
0.25
0.33
mA
0.1
1
µA
308
342
377
kHz
616
684
754
kHz
1 to 400
E = 0 lux, Gain/Range = 1
0
kHz
6
Counts
32767
3300
0.490
3
4400
0.515
Counts
5500
0.540
Counts
V
NOTES:
5. Fluorescent light is substituted by a green LED during production.
6. The voltage threshold levels of the SDA and SCL pins are VDD dependent: VTL = 0.35*VDD. VTH = 0.65*VDD.
7. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
2
FN6414.1
November 11, 2011
ISL29010
Pin Descriptions
PIN NUMBER
PIN NAME
DESCRIPTION
1
VDD
Positive supply; connect this pin to a regulated 2.5V to 3.3V supply
2
GND
Ground pin. The thermal pad is connected to the GND pin
3
REXT
External resistor pin for ADC reference; connect this pin to ground through a (nominal) 100k resistor with
1% tolerance
4
A0
5
SCL
I2C serial clock
6
SDA
I2C serial data
Bit 0 of I2C address
Principles of Operation
Photodiodes
The ISL29010 contains two photodiode arrays which convert
light into current. Some diodes are sensitive to both visible
and infrared light, while the others are only sensitive to
infrared light. Using the infrared portion of the light as
baseline, the visible light can be extracted. The spectral
response vs wavelength is shown in Figure 6 in the “Typical
Performance Curves” on page 9. After light is converted to
current during the light data process, the current output is
converted to digital by a single built-in integrating type signed
15-bit Analog-to-Digital Converter (ADC). An I2C command
reads the visible light intensity in counts.
The converter is a charge-balancing integrating type signed
15-bit ADC. The chosen method for conversion is best for
converting small current signals in the presence of an AC
periodic noise. A 100ms integration time, for instance, highly
rejects 50Hz and 60Hz power line noise simultaneously. See
“Integration Time or Conversion Time” on page 7 and “Noise
Rejection” on page 8.
The built-in ADC offers user flexibility in integration time or
conversion time. There are two timing modes: Internal Timing
Mode and External Timing Mode. In Internal Timing Mode,
integration time is determined by an internal dual speed
oscillator (fOSC), and the n-bit (n = 4, 8, 12, 16) counter inside
the ADC. In External Timing Mode, integration time is
determined by the time between two consecutive I2C External
Timing Mode commands. See External Timing Mode example.
A good balancing act of integration time and resolution
(depending on the application) is required for optimal results.
The I2C bus lines can pulled above VDD, 5.5V max.
set the high and low interrupt thresholds. There are four 8-bit
data Read Only registers, two bytes for the sensor reading and
another two bytes for the timer counts. The data registers
contain the ADC's latest digital output, and the number of clock
cycles in the previous integration period.
The ISL29010 has a 7-bit I2C interface slave address. The
six most significant bits are hardwired internally as 100010
while the least significant bit A0 can be either connected to
Ground or VDD to allow two possible addresses 1000100 or
1000101. When 1000100x or 1000101x with x as R or W is
sent after the Start condition, this device compares the first
seven bits of this byte to its address and matches.
Figure 1 shows a sample one-byte read. Figure 2 shows a
sample one-byte write. Figure 3 shows a sync_I2C timing
diagram sample for externally controlled integration time.
The I2C bus master always drives the SCL (clock) line, while
either the master or the slave can drive the SDA (data) line.
Figure 2 shows a sample write. Every I2C transaction begins
with the master asserting a start condition (SDA falling while
SCL remains high). The following byte is driven by the
master, and includes the slave address and read/write bit.
The receiving device is responsible for pulling SDA low
during the acknowledgement period.
Every I2C transaction ends with the master asserting a stop
condition (SDA rising while SCL remains high).
For more information about the I2C standard, please consult
the Philips® I2C specification documents.
The ADC has four I2C programmable range select to
dynamically accommodate various lighting conditions. For
very dim conditions, the ADC can be configured at its lowest
range. For very bright conditions, the ADC can be configured
at its highest range.
I2C Interface
There are eight (8) 8-bit registers available inside the ISL29010.
The command and control registers define the operation of the
device. The command and control registers do not change until
the registers are overwritten. There are two 8-bit registers that
3
FN6414.1
November 11, 2011
ISL29010
I2C DATA
Start
I2C SDA
In
DEVICE ADDRESS
A6
I2C SDA
Out
I2C CLK
A5
A4
A3
A2
A1
A0
W
A
W
A
SDA DRIVEN BY MASTER
1
2
3
4
5
6
REGISTER ADDRESS
R7
8
R5
R4
R3
R2
R1
R0
SDA DRIVEN BY MASTER
A
7
R6
A
9
1
2
3
4
5
6
7
8
STOP
DEVICE ADDRESS
START
A
A6
A5
A
SDA DRIVEN BY MASTER
9
1
2
A4
3
A3
A2
4
5
A1
6
A0
7
W
8
A
DATA BYTE0
A
A
SDA DRIVEN BY ISL29003
STOP
NAK
A
D7
D6
D5
D4
D3
D2
D1
D0
A
9
1
2
3
4
5
6
7
8
9
FIGURE 1. I2C READ TIMING DIAGRAM SAMPLE
I2C DATA
I2C SDA In
Start
DEVICE ADDRESS
W
A
A6 A5 A4 A3 A2 A1 A0
W
A
A
I2C SDA Out
I2C CLK In
SDA DRIVEN BY MASTER
1
2
3
4
5
6
7
8
9
REGISTER ADDRESS
A
FUNCTIONS
A
R7 R6 R5 R4 R3 R2 R1 R0
A
B7 B6 B5 B4 B3 B2 B1 B0
A
SDA DRIVEN BY MASTER
A
SDA DRIVEN BY MASTER
A
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
STOP
9
FIGURE 2. I2C WRITE TIMING DIAGRAM SAMPLE
I2 C D A T A
S t a rt
D E V IC E A D D R E S S
I2 C S D A In
A6
I2 C S D A O u t
A5
A4
A3
A2
A1
A0
W
A
W
A
S D A D R IV EN B Y M A S T ER
1
I2 C C L K In
2
3
4
5
6
R E G IS T E R A D D R E S S
R7
8
9
R5
R4
R3
R2
R1
R0
S D A D R IV EN B Y M A S T ER
A
7
R6
A S top
1
2
3
4
5
6
7
A
A
8
9
FIGURE 3. I2C SYNC_I2C TIMING DIAGRAM SAMPLE
4
FN6414.1
November 11, 2011
ISL29010
Register Set
There are eight registers that are available in the ISL29010. Table 1 summarizes the available registers and their functions.
TABLE 1. REGISTER SET
BIT
ADDR
REG NAME
7
6
5
4
3
2
1
0
DEFAULT
00h
COMMAND
ADCE
ADCPD
TIMM
0
ADCM1
ADCM0
RES1
RES0
00h
01h
CONTROL
0
0
0
0
GAIN1
GAIN0
0
0
00h
04h
LSB
SENSOR
S7
S6
S5
S4
S3
S2
S1
S0
00h
05h
MSB
SENSOR
S15
S14
S13
S12
S11
S10
S9
S8
00h
06h
LSB TIMER
T7
T6
T5
T4
T3
T2
T1
T0
00h
07h
MSB TIMER
T15
T14
T13
T12
T11
T10
T9
T8
00h
TABLE 2. WRITE ONLY REGISTERS
ADDRESS
REGISTER
NAME
b1xxx_xxxx
sync_I2C
bx1xx_xxxx
clar_int
TABLE 5. TIMING MODE
BIT 5
FUNCTIONS/DESCRIPTION
Writing a logic 1 to this address bit
ends the current ADC-integration
and starts another. Used only with
External Timing Mode.
Writing a logic 1 to this address bit
clears the interrupt.
Command Register 00(hex)
The Read/Write command register has five functions:
1. Enable; Bit 7.This function either resets the ADC or
enables the ADC in normal operation. A logic 0 disables
ADC to reset-mode. A logic 1 enables ADC to normal
operation.
TABLE 3. ENABLE
BIT 7
OPERATION
0
Disable ADC-core to reset-mode (default)
1
Enable ADC-core to normal operation
2. ADCPD; Bit 6. This function puts the device in a
power-down mode. A logic 0 puts the device in normal
operation. A logic 1 powers down the device.
TABLE 4. ADCPD
BIT 6
OPERATION
0
Normal operation (default)
1
Power Down
OPERATION
0
Internal Timing Mode. Integration time is internally
timed determined by fOSC, REXT, and number of
clock cycles.
1
External Timing Mode. Integration time is externally
timed by the I2C host.
4. Photodiode Select Mode; Bits 3 and 2. Setting Bit 3 and
Bit 2 to 1 and 0 enables ADC to give light count DATA
output.
TABLE 6. PHOTODIODE SELECT MODE; BITS 2 AND 3
BITS 3:2
MODE
0:0
Disable ADC
0:1
Disable ADC
1:0
Light count DATA output in signed (n - 1) bit *
1:1
No operation.
* n = 4, 8, 12,16 depending on the number of clock cycles
function.
5. Width; Bits 1 and 0. This function determines the number
of clock cycles per conversion. Changing the number of
clock cycles does more than just change the resolution of
the device. It also changes the integration time, which is
the period the device’s analog-to-digital (A/D) converter
samples the photodiode current signal for a lux
measurement.
TABLE 7. WIDTH
BITS 1:0
3. Timing Mode; Bit 5. This function determines whether the
integration time is done internally or externally. In Internal
Timing Mode, integration time is determined by an
internal dual speed oscillator (fOSC), and the n-bit
(n = 4, 8, 12, 16) counter inside the ADC. In External
Timing Mode, integration time is determined by the time
between three consecutive external-sync sync_I2C
pulses commands.
5
NUMBER OF CLOCK CYCLES
0:0
216 = 65,536
0:1
212 = 4,096
1:0
28 = 256
1:1
24 = 16
FN6414.1
November 11, 2011
ISL29010
Control Register 01(hex)
The Read/Write control register has one function:
1. Range/Gain; Bits 3 and 2. The Full Scale Range can be
adjusted by an external resistor REXT and/or it can be
adjusted via I2C using the Gain/Range function.
Gain/Range has four possible values, Range(k) where k
is 1 through 4. Table 8 lists the possible values of
Range(k) and the resulting FSR for some typical value
REXT resistors.
TABLE 8. RANGE/GAIN TYPICAL FSR LUX RANGES
FSR LUX
RANGE@
BITS
3:2 k RANGE(k) REXT = 100k
FSR LUX
RANGE@
REXT = 50k
FSR LUX
RANGE@
REXT = 500k
0:0
1
2,000
2,000
4,000
400
0:1
2
8,000
8,000
16,000
1,600
1:0
3
32,000
32,000
64,000
6,400
1:1
4
128,000
128,000
256,000
25,600
I2Sensor Data Register 04(hex) and 05(hex)
When the device is configured to output a signed 15-bit data,
the most significant byte is accessed at 04(hex), and the
least significant byte can be accessed at 05(hex). The
sensor data register is refreshed after every integration
cycle.
Timer Data Register 06(hex) and 07(hex)
Note that the timer counter value is only available when
using the External Timing Mode. The 06(hex) and 07(hex)
are the LSB and MSB, respectively, of a 16-bit timer counter
value corresponding to the most recent sensor reading.
Each clock cycle increments the counter. At the end of each
integration period, the value of this counter is made available
over the I2C. This value can be used to eliminate noise
introduced by slight timing errors caused by imprecise
external timing. Microcontrollers, for example, often cannot
provide high-accuracy command-to-command timing, and
the timer counter value can be used to eliminate the
resulting noise.
TABLE 9. DATA REGISTERS
The proportionality constant  is determined by the Full
Scale Range (FSR), and the n-bit ADC, which is user
defined in the command register. The proportionality
constant can also be viewed as the resolution; the smallest
lux measurement the device can measure is in Equation 2.
FSR
 = -----------n
2
(EQ. 2)
Full-Scale Range (FSR) is determined by the software
programmable Range/Gain, Range(k), in the command
register and an external scaling resistor REXT, which is
referenced to 100k.
(EQ. 3)
100k
FSR = Range  k   -----------------R EXT
The transfer function effectively for each timing mode
becomes:
INTERNAL TIMING MODE
100k
Range  k   -----------------R EXT
E = ----------------------------------------------------  DATA
n
2
(EQ. 4)
EXTERNAL TIMING MODE
100k
Range  k   -----------------R EXT
E = ----------------------------------------------------  DATA
COUNTER
(EQ. 5)
n = 3, 7, 11, or 15. This is the number of clock cycles
programmed in the command register.
Range(k) is the user defined range in the Gain/Range bit
in the command register.
REXT is an external scaling resistor hardwired to the REXT
pin.
DATA is the output sensor reading in number of counts
available at the data register.
2n represents the maximum number of counts possible in
Internal Timing Mode. For the External Timing Mode, the
maximum number of counts is stored in the data register
named COUNTER.
COUNTER is the number of increments accrued between
integration time for External Timing Mode.
ADDRESS
(hex)
CONTENTS
04
Least-significant byte of most recent sensor reading.
Gain/Range, Range(k)
05
Most-significant byte of most recent sensor reading.
06
Least-significant byte of timer counter value
corresponding to most recent sensor reading.
07
Most-significant byte of timer counter value
corresponding to most recent sensor reading.
The Gain/Range can be programmed in the control register
to give Range(k) determining the FSR. Note that Range(k) is
not the FSR (see Equation 3). Range(k) provides four
constants depending on programmed k that will be scaled by
REXT (see Table 8). Unlike REXT, Range(k) dynamically
adjusts the FSR. This function is especially useful when light
conditions are varying drastically while maintaining excellent
resolution.
Calculating Lux
The ISL29010’s output codes, DATA, are directly
proportional to lux.
(EQ. 1)
E =   DATA
6
FN6414.1
November 11, 2011
ISL29010
Number of Clock Cycles, n-bit ADC
Integration Time or Conversion Time
The number of clock cycles determines “n” in the n-bit ADC; 2n
Integration time is the period during which the device’s
analog-to-digital ADC converter samples the photodiode
current signal for a lux measurement. Integration time, in
other words, is the time to complete the conversion of analog
photodiode current into a digital signal (number of counts).
clock cycles is a n-bit ADC. n is programmable in the command
register in the width function. Depending on the application, a
good balance of speed and resolution has to be considered
when deciding for n. For fast and quick measurement, choose
the smallest n = 3. For maximum resolution without regard of
time, choose n = 15. Table 10 compares the trade-off between
integration time and resolution. See Equations 10 and 11 for the
relation between integration time and n. See Equation 3 for the
relation of n and resolution.
TABLE 10. RESOLUTION AND INTEGRATION TIME
SELECTION
RANGE1
fOSC = 327kHz
RANGE4
fOSC = 655kHz
n
tINT
(ms)
RESOLUTION
LUX/COUNT
tINT
(ms)
RESOLUTION
(LUX/COUNT)
15
200
0.06
100
2
11
12.8
1.0
6.4
62.5
7
0.8
15.6
0.4
1,000
3
0.05
250
0.025
16,000
Integration time affects the measurement resolution. For
better resolution, use a longer integration time. For short and
fast conversions use a shorter integration time.
The ISL29010 offers user flexibility in the integration time to
balance resolution, speed and noise rejection. Integration time
can be set internally or externally and can be programmed in
the command register 00(hex) Bit 5.
INTEGRATION TIME IN INTERNAL TIMING MODE
This timing mode is programmed in the command register
00(hex) Bit 5. Most applications will be using this timing
mode. When using the Internal Timing Mode, fOSC and
n-bits resolution determine the integration time. tINT is a
function of the number of clock cycles and fOSC.
t INT = 2
m
1
 ---------f osc
(EQ. 9)
for Internal Timing Mode only
REXT = 100k
m = 4, 8, 12, and16. n is the number of bits of resolution.
External Scaling Resistor REXT and fosc
The ISL29010 uses an external resistor REXT to fix its
internal oscillator frequency, fOSC. Consequently, REXT
determines the fOSC, integration time and the FSR of the
device. fOSC, a dual speed mode oscillator, is inversely
proportional to REXT. For user simplicity, the proportionality
constant is referenced to fixed constants 100k and
655kHz:
1 100k
f OSC 1 = ---  ------------------  655 kHz
2 R EXT
(EQ. 6)
100k
f OSC 2 = ------------------  655 kHz
R EXT
(EQ. 7)
fOSC1 is oscillator frequency when Range1 or Range2 are
set. This is nominally 327kHz when REXT is 100k.
fOSC2 is the oscillator frequency when Range3 or Range4
are set. This is nominally 655kHz when REXT is 100k.
When the Range/Gain bits are set to Range1 or Range2,
fOSC runs at half speed compared to when Range/Gain bits
are set to Range3 and Range4.
(EQ. 8)
1
f OSC 1 = ---  f OSC 2 
2
The automatic fOSC adjustment feature allows significant
improvement of signal-to-noise ratio when detecting very low
lux signals.
2m therefore is the number of clock cycles. n can be
programmed at the command register 00(hex) Bits 1 and 0.
Since fOSC is dual speed depending on the Gain/Range bit,
tINT is dual time. The integration time as a function of REXT
is shown in Equation 10:
t INT 1 = 2
m
R EXT
 ---------------------------------------------327kHz  100k
(EQ. 10)
tINT1 is the integration time when the device is configured
for Internal Timing Mode and Gain/Range is set to Range1
or Range2.
t INT 2 = 2
m
R EXT
 ---------------------------------------------655kHz  100k
(EQ. 11)
tINT2 is the integration time when the device is configured
for Internal Timing Mode and Gain/Range is set to Range3
or Range4.
TABLE 11. INTEGRATION TIMES FOR TYPICAL REXT VALUES
RANGE1
RANGE2
RANGE3
RANGE4
REXT
(k
n = 15-BIT
n = 11-BIT
n = 11-BIT
n=3
50
100
6.4
3.2
0.013
100**
200
13
6.5
0.025
200
400
26
13
0.050
500
1000
64
32
0.125
*Integration time in milliseconds
**Recommended REXT resistor value
7
FN6414.1
November 11, 2011
ISL29010
INTEGRATION TIME IN EXTERNAL TIMING MODE
This timing mode is programmed in the command register
00(hex) Bit 5. External Timing Mode is recommended when
integration time can be synchronized to an external signal
such as a PWM to eliminate noise.
To read the light count DATA output, the device needs three
sync_I2C commands to complete one measurement. The 1st
sync_I2C command starts the conversion of the diode array 1.
The 2nd sync_I2C completes the conversion of diode array 1
and starts the conversion of diode array 2. The 3rd sync_I2C
pules ends the conversion of diode array 2, outputs the light
count DATA, and starts over again to commence conversion
of diode array 1.
The integration time, tINT, is the sum of two identical time
intervals between the three sync pulses. tINT is determined
by Equation 12:
k OSC
t INT = --------------f OSC
plastic material. A thickness of t = 1mm is recommended for
a window lens design. The bigger the diameter of the
window lens, the wider the viewing angle is of the ISL29010.
Table 12 shows the recommended dimensions of the optical
window to ensure both 35° and 45° viewing angle. These
dimensions are based on a window lens thickness of 1.0mm
and a refractive index of 1.59.
WINDOW LENS
t
DTOTAL

ISL29013
D1
DLENS
(EQ. 12)
where kOSC is the number of internal clock cycles obtained
from Timer data register and fOSC is the internal I2C
operating frequency.
The internal oscillator, fOSC, operates identically in both the
internal and external timing modes, with the same
dependence on REXT. However, in External Timing Mode,
the number of clock cycles per integration is no longer fixed
at 2n. The number of clock cycles varies with the chosen
integration time, and is limited to 216 = 65,536. In order to
avoid erroneous lux readings the integration time must be
short enough not to allow an overflow in the counter register.
65,535
t INT  -----------------f OSC
(EQ. 13)
fOSC = 327kHz*100k/REXT. When Range/Gain is set to
Range1 or Range2.
fOSC = 655kHz*100k/REXT. When Range/Gain is set to
Range3 or Range4.
E=
DATA
215
x 2000
 = VIEWING ANGLE
FIGURE 4. FLAT WINDOW LENS
TABLE 12. RECOMMENDED DIMENSIONS FOR A FLAT
WINDOW DESIGN
DTOTAL
D1
DLENS @ 35
VIEWING ANGLE
DLENS @ 45
VIEWING ANGLE
1.5
0.50
2.25
3.75
2.0
1.00
3.00
4.75
2.5
1.50
3.75
5.75
3.0
2.00
4.30
6.75
3.5
2.50
5.00
7.75
t=1
D1
DLENS
DTOTAL
Thickness of lens
Distance between ISL29010 and inner edge of lens
Diameter of lens
Distance constraint between the ISL29010 and lens
outer edge
* All dimensions are in mm.
Noise Rejection
Suggested PCB Footprint
In general, integrating type ADC’s have excellent
noise-rejection characteristics for periodic noise sources
whose frequency is an integer multiple of the integration
time. For instance, a 60Hz AC unwanted signal’s sum from
0ms to k*16.66ms (k = 1,2...ki) is zero. Similarly, setting the
device’s integration time to be an integer multiple of the
periodic noise signal greatly improves the light sensor output
signal in the presence of noise.
It is important that the users check the “Surface Mount
Assembly Guidelines for Optical Dual FlatPack No Lead
(ODFN) Package” before starting ODFN product board
mounting.
Flat Window Lens Design
A window lens will surely limit the viewing angle of the
ISL29010. The window lens should be placed directly on top
of the device. The thickness of the lens should be kept at
minimum to minimize loss of power due to reflection and
also to minimize loss due to absorption of energy in the
8
http://www.intersil.com/data/tb/TB477.pdf
Layout Considerations
The ISL29010 is relatively insensitive to layout. Like other
I2C devices, it is intended to provide excellent performance
even in significantly noisy environments. There are only a
few considerations that will ensure best performance.
FN6414.1
November 11, 2011
ISL29010
Route the supply and I2C traces as far as possible from all
sources of noise. Use two power-supply decoupling
capacitors, 4.7µF and 0.1µF, placed close to the device.
Soldering Considerations
Convection heating is recommended for reflow soldering;
direct-infrared heating is not recommended. The plastic
ODFN package does not require a custom reflow soldering
profile, and is qualified to +260°C. A standard reflow
soldering profile with a +260°C maximum is recommended.
Typical Circuit
A typical application for the ISL29010 is shown in Figure 5.
The ISL29010’s I2C address is internally hardwired as
1000100. The device can be tied onto a system’s I2C bus
together with other I2C compliant devices.
1.8V TO 5.5V
I2C MASTER
R2
10k
R1
10k
MICROCONTROLLER
SDA
SCL
2.5V TO 3.3V
I2C SLAVE_0
1
2
C1
4.7µF
C2
0.1µF
3
VDD
SDA
GND
SCL
REXT
A0
I2C SLAVE_1
I2C SLAVE_n
6
SDA
SDA
5
SCL
SCL
4
REXT ISL29010
100k
FIGURE 5. ISL29010 TYPICAL CIRCUIT
Typical Performance Curves (REXT = 100k)
NORMALIZED RESPONSE
1.2
RADIATION PATTERN
HUMAN EYE RESPONSE
1.0
LUMINOSITY
30°
ANGLE 40°
0.8
20°
10°
0°
10°
20°
30°
40°
50°
50°
0.6
ISL29010 RESPONSE
60°
60°
0.4
70°
70°
0.2
80°
0.0
-0.2
90°
300
400
600
800
WAVELENGTH (nm)
FIGURE 6. SPECTRAL RESPONSE
9
1.0k
1.1k
80°
0.2 0.4
0.6 0.8
RELATIVE SENSITIVITY
90°
1.0
FIGURE 7. RADIATION PATTERN
FN6414.1
November 11, 2011
ISL29010
Typical Performance Curves (REXT = 100k)
(Continued)
320
TA = +27°C
1.0
SUN
0.8
HALOGEN
0.6
INCANDESCENT
FLUORESCENT
0.4
SUPPLY CURRENT (mA)
NORMALIZED LIGHT INTENSITY
1.2
0.2
0
300
400
500
600
700
800
900
1000
306
5000 lux
292
278
200 lux
264
250
2.0
1100
2.3
2.6
WAVELENGTH (nm)
FIGURE 8. SPECTRUM OF LIGHT SOURCES FOR
MEASUREMENT
OUTPUT CODE RATIO
(% FROM 3V)
OUTPUT CODE (COUNTS)
6
4
RANGE 2
2
2.6
2.9
3.2
3.5
1.010
5000 lux
1.005
1.000
0.990
2.0
3.8
200 lux
0.995
2.3
SUPPLY VOLTAGE (V)
2.9
3.2
3.5
3.8
FIGURE 11. OUTPUT CODE vs SUPPLY VOLTAGE
315
320.0
VDD = 3V
TA = +27°C
SUPPLY CURRENT (mA)
OSCILLATOR FREQUENCY (kHz)
2.6
SUPPLY VOLTAGE (V)
FIGURE 10. OUTPUT CODE FOR 0 LUX vs SUPPLY VOLTAGE
319.5
319.0
318.5
318.0
2.0
3.8
TA = +27°C
0 lux
2.3
3.5
1.015
TA = +27°C
0
2.0
3.2
FIGURE 9. SUPPLY CURRENT vs SUPPLY VOLTAGE
10
8
2.9
SUPPLY VOLTAGE (V)
2.3
2.6
2.9
3.2
3.5
3.8
SUPPLY VOLTAGE (V)
FIGURE 12. OSCILLATOR FREQUENCY vs SUPPLY VOLTAGE
10
305
5000 lux
RANGE 3
295
285
200 lux
RANGE 1
275
265
-60
-20
20
60
100
TEMPERATURE (°C)
FIGURE 13. SUPPLY CURRENT vs TEMPERATURE
FN6414.1
November 11, 2011
ISL29010
Typical Performance Curves (REXT = 100k)
(Continued)
1.080
VDD = 3V
VDD = 3V
0 lux
8
OUTPUT CODE RATIO
(% FROM +25°C)
OUTPUT CODE (COUNTS)
10
6
4
RANGE 2
2
0
-60
-20
20
1.048
5000 lux
RANGE 3
1.016
200 lux
RANGE 1
0.984
0.952
0.920
-60
60
-20
TEMPERATURE (°C)
FIGURE 14. OUTPUT CODE FOR 0 LUX vs TEMPERATURE
CALCULATED ALS READING (LUX)
OSCILLATOR FREQUENCY (kHz)
100
14000
VDD = 3V
329
328
327
326
325
-60
-20
20
60
VDD = 3V
12000
HALOGEN
10000
FLUORESCENT
6000
4000
2000
0
100
TYPICAL OUTPUT LUX VARIATION
BETWEEN FOUR LIGHT SOURCES: +15%
0
2k
4k
CALCULATED ALS READING (LUX)
HALOGEN
800
700
INCANDESCENT
600
FLUORESCENT
500
400
300
200
100
0
100
200
300
400
500
600
700
800
900
LUX METER READING (LUX)
FIGURE 18. LIGHT SENSITIVITY vs LUX LEVEL
11
8k
10k
12k
14k
FIGURE 17. LIGHT SENSITIVITY vs LUX LEVEL
100
VDD = 3V
900
6k
LUX METER READING (LUX)
FIGURE 16. OSCILLATOR FREQUENCY vs TEMPERATURE
1000
SUN
INCANDESCENT
8000
TEMPERATURE (°C)
CALCULATED ALS READING (LUX)
60
FIGURE 15. OUTPUT CODE vs TEMPERATURE
330
0
20
TEMPERATURE (°C)
1k
VDD = 3V
90
HALOGEN
80
70
FLUORESCENT
60
50
40
INCANDESCENT
30
20
10
0
0
10
20
30
40
50
60
70
80
90
100
LUX METER READING (LUX)
FIGURE 19. LIGHT SENSITIVITY vs LUX LEVEL
FN6414.1
November 11, 2011
ISL29010
2.00mm
SENSOR OFFSET
2.10mm
1
6
2
5
0.29mm
0.56mm
3
4
0.46mm
FIGURE 20. 6 LD ODFN SENSOR LOCATION OUTLINE
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9001 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
12
FN6414.1
November 11, 2011
ISL29010
Package Outline Drawing
L6.2x2.1
6 LEAD OPTICAL DUAL FLAT NO-LEAD PLASTIC PACKAGE (ODFN)
Rev 3, 5/11
2.10
A
6
PIN #1
INDEX AREA
B
6
PIN 1
INDEX AREA
1
0.65
1.35
2.00
1.30 REF
4 6X 0.30±0.05
(4X)
0.10
0.10 M C A B
0.65
TOP VIEW
6x0.35 ± 0.05
BOTTOM VIEW
2.50
PACKAGE
OUTLINE
2.10
SEE DETAIL "X"
0.65
(4x0.65)
0.10 C
MAX 0.75
C
BASE PLANE
SEATING PLANE
0.08 C
SIDE VIEW
(1.35)
(6x0.30)
C
(6x0.20)
0 . 2 REF
5
0 . 00 MIN.
0 . 05 MAX.
(6x0.55)
TYPICAL RECOMMENDED LAND PATTERN
DETAIL "X"
NOTES:
1.
Dimensions are in millimeters.
Dimensions in ( ) for Reference Only.
2.
Dimensioning and tolerancing conform to ASME Y14.5m-1994.
3.
Unless otherwise specified, tolerance : Decimal ± 0.05
4.
Dimension applies to the metallized terminal and is measured
between 0.15mm and 0.30mm from the terminal tip.
5.
Tiebar shown (if present) is a non-functional feature.
6.
The configuration of the pin #1 identifier is optional, but must be
located within the zone indicated. The pin #1 identifier may be
either a mold or mark feature.
13
FN6414.1
November 11, 2011