ux-a5b ds en

VRM = 4 kV, IF(AV) = 350 mA
High Frequency and High Voltage Rectifier Diode
UX-A5B
Features
Package
The UX-A5B is a low-loss and high-voltage rectifier
diode with a peak reverse voltage of 4 kV.
The product achieved a typical forward voltage drop
of 6.0 V and a typical trr-time of 0.06 μs by optimizing
trade-offs between the forward voltage drop (VF) and the
reverse recovery time (trr).
Axial (□7/φ1.2)
 VRM-------------------------------------------------------- 4 kV
 VF-------------------------------------------------- 8.0 V max.
 IF(AV)--------------------------------------------------- 350 mA
 trr ------------------------------------------------- 0.15 μs max.
(IF = 100 mA, IRP = 100 mA, 90 % of R.P.)
Applications
 High Voltage Control Circuits
 Inverter Microwave Oven, etc.
Absolute Maximum Ratings
 Unless otherwise specified, TA is 25 °C
Parameter
Notes
Symbol
Rating
Unit
Peak Repetitive Reverse Voltage
VRM
4
kV
Average Forward Current
IF(AV)
350
mA
Surge Forward Current
IFSM
15
A
Junction Temperature
Tj
120
°C
Storage Temperature
Tstg
−40 to +130
°C
Test Conditions
Min.
Typ.
Max.
Unit
50Hz
Half sinewave, one shot
Electrical Characteristics
 Unless otherwise specified, TA is 25 °C
Parameter
Symbol
Forward Voltage Drop
VF
IF = 350 mA
―
6.0
8.0
V
Reverse Leakage Current
IR
VR = VRM
―
―
10
µA
Reverse Breakdown Voltage
VZ
IR =100 μA
4.3
―
―
kV
Reverse Recovery Time
trr
IF = IRP = 100 mA,
Tj = 25 °C,
90 % recovery point
―
0.06
0.15
μs
UX-A5B-DS Rev.1.01
Apr. 02, 2015
SANKEN ELECTRIC CO.,LTD.
http://www.sanken-ele.co.jp/en/
1
UX-A5B
Performance Curves
VF-IF(typ.) UX-A5B
VR-IR(typ.) UX-A5B
1.E-02
1
1.E-03
25℃
IR (A)
IF (A)
1.E-04
0.1
1.E-05
1.E-06
1.E-07
25℃
1.E-08
0.01
0
5
10
15
20
0
VF (V)
UX-A5B-DS Rev.1.01
Apr. 02, 2015
1
2
3
4
5
6
VR (kV)
SANKEN ELECTRIC CO.,LTD.
2
UX-A5B
Package Outline
φ1.2
Axial (□7/φ1.2)
UX – A5B
SK
21 min.
7±0.5
21±1
21 min.
7±0.5
NOTES:
1) Dimension is in millimeters
2) Pb-free. Device composition compliant with the RoHS directive
Marking Diagram
UX – A5B
SK
YMDD
Part Number
Lot Number
Y is the Last digit of year (0 to 9)
M is the Month (1 to 9, O, N or D)
DD is the Date (two digit of 01 to 31)
UX-A5B-DS Rev.1.01
Apr. 02, 2015
SANKEN ELECTRIC CO.,LTD.
3
UX-A5B
OPERATING PRECAUTIONS
In the case that you use Sanken products or design your products by using Sanken products, the reliability largely
depends on the degree of derating to be made to the rated values. Derating may be interpreted as a case that an operation
range is set by derating the load from each rated value or surge voltage or noise is considered for derating in order to
assure or improve the reliability. In general, derating factors include electric stresses such as electric voltage, electric
current, electric power etc., environmental stresses such as ambient temperature, humidity etc. and thermal stress caused
due to self-heating of semiconductor products. For these stresses, instantaneous values, maximum values and minimum
values must be taken into consideration. In addition, it should be noted that since power devices or IC’s including power
devices have large self-heating value, the degree of derating of junction temperature affects the reliability significantly.
Because reliability can be affected adversely by improper storage environments and handling methods, please
observe the following cautions.
Cautions for Storage
 Ensure that storage conditions comply with the standard temperature (5 to 35°C) and the standard relative humidity
(around 40 to 75%); avoid storage locations that experience extreme changes in temperature or humidity.
 Avoid locations where dust or harmful gases are present and avoid direct sunlight.
 Reinspect for rust on leads and solderability of the products that have been stored for a long time.
Cautions for Testing and Handling
When tests are carried out during inspection testing and other standard test periods, protect the products from power
surges from the testing device, shorts between the product pins, and wrong connections. Ensure all test parameters are
within the ratings specified by Sanken for the products.
Soldering
 When soldering the products, please be sure to minimize the working time, within the following limits:
• 260 ± 5 °C
10 ± 1 s (Flow, 2 times)
• 380 ± 10 °C 3.5 ± 0.5 s (Soldering iron, 1 time)
 Soldering should be at a distance of at least 1.5 mm from the body of the products.
UX-A5B-DS Rev.1.01
Apr. 02, 2015
SANKEN ELECTRIC CO.,LTD.
4
UX-A5B
IMPORTANT NOTES
 The contents in this document are subject to changes, for improvement and other purposes, without notice. Make
sure that this is the latest revision of the document before use.
 Application and operation examples described in this document are quoted for the sole purpose of reference for the
use of the products herein and Sanken can assume no responsibility for any infringement of industrial property
rights, intellectual property rights or any other rights of Sanken or any third party which may result from its use.
 Unless otherwise agreed in writing by Sanken, Sanken makes no warranties of any kind, whether express or
implied, as to the products, including product merchantability, and fitness for a particular purpose and special
environment, and the information, including its accuracy, usefulness, and reliability, included in this document.
 Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and
defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at
their own risk, preventative measures including safety design of the equipment or systems against any possible
injury, death, fires or damages to the society due to device failure or malfunction.
 Sanken products listed in this document are designed and intended for the use as components in general purpose
electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring
equipment, etc.).
When considering the use of Sanken products in the applications where higher reliability is required (transportation
equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various
safety devices, etc.), and whenever long life expectancy is required even in general purpose electronic equipment
or apparatus, please contact your nearest Sanken sales representative to discuss, prior to the use of the products
herein.
The use of Sanken products without the written consent of Sanken in the applications where extremely high
reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly
prohibited.
 When using the products specified herein by either (i) combining other products or materials therewith or (ii)
physically, chemically or otherwise processing or treating the products, please duly consider all possible risks that
may result from all such uses in advance and proceed therewith at your own responsibility.
 Anti radioactive ray design is not considered for the products listed herein.
 Sanken assumes no responsibility for any troubles, such as dropping products caused during transportation out of
Sanken’s distribution network.
 The contents in this document must not be transcribed or copied without Sanken’s written consent.
UX-A5B-DS Rev.1.01
Apr. 02, 2015
SANKEN ELECTRIC CO.,LTD.
5