LITTELFUSE STD200

POLYFUSE® RESETTABLE FUSES
STD
Strap Type, 15 V / 24 V
Specifications
Standard
Packaging
A
small pack
D
standard
Approvals
Materials
Insulating material: Polyester Tape
Terminals:
Nickel
Features
Max. Device Surface Temperature in Tripped State
UL 1434 1st Edition
CSA C22.2 No. 0 CSA TIL No. CA-3A
cULus Recognition
TÜV
125 °C
This axial leaded strap product is designed to
provide reliable, non-cycling protection for rechargeable batteries. The weldable nickel leads
with a narrow, low profile design are ideal to be
installed directly onto battery cells.
Dimensions (mm)
Operating / Storage Temperature
-40 ºC to +85 ºC (consider derating)
Humidity Ageing
+85 °C, 85 % R.H., 7 days, ± 5 % typical resistance change
Vibration
MIL-STD-883C, Condition A, no change
Marking
“P”, Part Code, identification, lot number
S: one slot
Dimensions (mm)
Model
STD120
STD120S
STD175
STD175S
STD200
STD350
STD420
Fig
Min
1
2
1
2
1
1
1
19.9
19.9
20.9
20.9
23.3
28.4
30.6
A
Max
B
Min Max
C
Min Max
D
Min
22.1
22.1
23.1
23.1
23.4
31.8
32.4
4.9
4.9
4.9
4.9
10.2
13.0
12.9
0.6
0.6
0.6
0.6
0.5
0.5
0.5
5.5
5.5
4.1
4.1
5.0
6.3
5.0
5.2
5.2
5.2
5.2
11.0
13.5
13.6
1.0
1.0
1.0
1.0
1.1
1.1
1.1
E
Min Max
3.9
3.9
3.9
3.8
4.8
6.0
5.0
4.1
4.1
4.1
4.2
5.4
6.6
6.7
packaging quantity
small pack
standard
500
500
500
500
500
500
500
10,000
10,000
10,000
10,000
10,000
5,000
5,000
Permissible continuous operating current is ≤ 100 % at ambient temperature of 20 ºC (68 ºF).
NOTE:
I hold =
I trip =
Vmax =
I max =
Vmax. dc
(V)
Imax.
(A)
1.20A
1.20A
1.75A
1.75A
2.00A
3.50A
4.20A
2.7
2.7
3.8
3.8
4.4
6.3
7.6
15V
15V
15V
15V
24V
24V
24V
100
100
100
100
100
100
100
Hold current: maximum current device will pass without tripping in 20 °C still air.
Trip current: minimum current at which the device will trip in 20 °C still air.
Maximum voltage device can withstand without damage at rated current (I max)
Maximum fault current device can withstand without damage at rated voltage (Vmax)
Order
Information
041006
ITrip
(A)
Qty.
OrderNumber
Model
max. time to trip
(s @ A)
5.00 @ 6.00
5.00 @ 6.00
5.00 @ 8.75
5.00 @ 8.75
4.00 @ 10.00
3.00 @ 20.00
6.00 @ 20.00
Pd max.
(W)
1.20
1.20
1.50
1.50
1.90
2.50
2.90
Resistance
R min.( )
R max.( )
0.085
0.085
0.050
0.050
0.030
0.017
0.012
0.160
0.160
0.090
0.090
0.060
0.031
0.024
Approvals
RI max.( )
0.220
0.220
0.120
0.120
0.100
0.050
0.040
TÜV
STD120
STD120S
STD175
STD175S
STD200
STD350
STD420
Ihold
(A)
cURus
Model
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Pd =
Power dissipated from device when in the tripped state at 20 °C still air.
Minimum resistance of device in initial (un-soldered) state.
R min=
Maximum resistance of device at 20 °C measured one hour after tripping for 20 s.
R 1max=
Caution: Operation beyond the specified rating may result in damage and possible arcing and flame.
Specifications are subject to change without notice
Packaging
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
www.littelfuse.com
POLYFUSE® RESETTABLE FUSES
STD
A
B
C
DE
A: STD120
B: STD175
C: STD200
D: STD350
E: STD420
Further Time-Current-Curves on request
Thermal Derating Chart
Model
STD120
STD120S
STD175
STD175S
STD200
STD350
STD420
041006
Ambient Operation Temperature - Ihold (A)
-40 °C
-20 °C
0 °C
23 °C
40 °C
50 °C
60 °C
70 °C
85 °C
1.90
1.90
2.50
2.50
3.20
5.40
6.40
1.70
1.70
2.30
2.30
2.80
4.80
5.70
1.50
1.50
2.00
2.00
2.50
4.30
5.10
1.20
1.20
1.75
1.75
2.00
3.50
4.20
1.00
1.00
1.50
1.50
1.70
3.00
3.60
0.90
0.90
1.30
1.30
1.60
2.80
3.30
0.80
0.80
1.20
1.20
1.40
2.50
3.00
0.70
0.70
1.10
1.10
1.20
2.20
2.60
0.50
0.50
0.90
0.90
0.90
1.70
2.10
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
www.littelfuse.com