ICPTest_216XEP_11 29 2012 pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
216 series Axial Leaded Fuse
Product #:
216XEP
Issue Date:
November 29, 2012
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC,
2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Engineer >
(1) Parts, sub-materials and unit parts
This document covers the 5x20 Fuse RoHS-Compliant series products manufactured by
Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
Raw Material Part Number
910-005
692539-002
909-455
091251
082xxx
C030210
Raw Material Description
Cap
Solder
Body
Sand Filler (RoHs & Halogens)
Wire-AgCu
Overcap
2
Page(s)
3-6
7-11
12-22
23-29
30-39
40-43
nov^
TESTREPORT
NO.4002R12050740-1R02
Daie:May.09,2012
Cu8tomer:SuzhouFuHongElectrcnic
IndustrialCo.,
Ltd.
AddT€€3:NO,69\ryEIDUROAD,WANGTING
TO\M{,XIANGCHENG
OISTRICISUZHOU.
CHINA
R€pot on the submitt€d sample sald to b€
Samplenah€: Copp€rsh€ll
Supplier:/
Samplerocolv€ddate:lvlay.07, 2012
T6tf ng pedod: Frcmluay.07,29l2toMay.A9,2012
T€€tino R€ou€6tod
As specifiedby clienl,lo delerminethe Lead,Cadmium,
l\,telcury
& Hexavalent
Chrcmiummntentin the submitledsamplein
.ccodancewilh Dircctive200295/EC(RoHS).
T€stino method:
I\l1QL
IEC62321:2008,seclionI
cadmium(Cd)
IEC62321:2008,seclion9
Mercury(Hs)
(CrVI)
chrcmium
IEC62321 2008,s€ction7
tcP-oEs
rcP-oEs
tcP-oEs
IEC62321i200EAnn€xB
2mg/kg
2 mg/kg
2 mSeS
0.02mg/kg'
Ieq
r 0.02mgl(g efers to the MQLofsampbenractiontiquid.
Concll|3ion:
-Whenlestedas specifiedlhe submitledsampl€€ompliedwith the requircments
of commission
Decisionof 18 Aug 2005
amendingDirecnve
2002r95/Ecnotifiedunderdocument
2005/61E/Ec.
*'*FOR FURTHERDETAILS.
PLEASEREFERTOTHEFOLLOWING
PAGE{S).*'"
Sigmdior andon behalfof
Shenzhen
AOVTeslingTechnology
Co.,Lld,KunshanBranch
/uI?'
,.r.ou.o.,,
oro.'n,44.
Li nngtng, lMaggie
Ch€micalTestDi€ctor
S}I€I\IZIIENAOV TESTINGTECHNOLOGY
CO.,ITD.(UI{SHAN ERANCH
ol:9Jllis,.*""
nov'
TESTREPORT
NO. A002R12050740-1R02
Add lhe digeslion€olution;lhe
vesselis heal€dunlilthe sample
f*;;1.,-
Coolinglhe vessel,fiteri washedand
T6st€dby tCP-OEs
filledto the man(withdislilledwater
Th8sampleis digesredin the
micrcwave
ov€niollowinga specific
decompositionprogram
Coolinglhevessol,filtsr;wasi€d and
filledlo lhe markwilhdistilled
water.
(boitingChromium
Content
warerext€crion)r
subsrrare)
{Mstat
Removetnesample,snd cool
Heal50 mL ofDlwalerin the
beakerto boilingfor 'l 0 min
-j.f*--*
lhe beakerto rcomtemp€€turc,
anddo the colorr€action
Testlhe samplesolutionandlhe 0.02
mg/kgstandardsolutionby W-VIS.
ToDsbmine d,C4lmiumandMercury
Conbnt(Plating)
Cooling,filter;washed
andfjll€d
lo lhe markwithDl water.
-------------l
-r€st€d by
________'
l__rl nupo,r I
Instumenl |
SHENZHEI\I
AOV T€STII{OTECHI{OLOGY
CO.,!TO.XUNSTIA BNA CH
|
|
Hotllne
nov'
TESTREPORT
NO
Dats:iray 09,2012
Page3ot4
5. To DetemineH€xavalent
Ch.omiumContenlin colorlessand coloredchromatecoalingon metals:(Plaling)
",ffii'Q*a*
lf lh€ tast r€sult is positive,
lhe samplels considered
lo
hav€hexavalenl
chromium
lfthe l€st tesull
and lhe 0.0?mg/kg
Boiling- waler- enraclion
proc€dureshall be used to
lfthe|eis interierence
oritis hardlodecidewhether
the samplehavelhe ho(avalent
chromium
5.2 Boiling-waleFexlraclion
Takethe (5015)cm'z
Remov€lhe sample,andcool
Heats0 mloforwalerin lhe
beaker
!o boiling
for10min
the b€akorlo roomtsmp€ralute,
anddo the colorreaction
Teslthe samplesolution
andthe 0.02
mg/kgslandaritsolutionby UV-VIS.
Pl€ring
Lead(Pb)
(cd)
cadmium
(Hg)
Mercury
(Cr\,I)
chromium
Unil
RoHSLimil
mg/xg
1000
100
1000
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
1000
Negalive
Negalive
mg/Kg
mg/xg
mg/xg
SHENZHENAOV TISTII{G IECHNOfOGYCO.,!TO.XUNSIIATINA CH
Hotline
36.512-55100000
novTESTREPORT
NO.:4002R12050740-1R02
-Tnen€w RoHSdi€ctive2011/65/EU,
on Jul.21, 2011 com€inloiorce,on Jan 03,2013 thefomat imptemenlaton,
Dircctrve
2002/95/EC
sh.ll be rcp€aledsimultaneousty.
-Specimens,
whichrequesred
to detemineLead,Cadmiumand MercuryConrent,
haveboendissotved
compt€r€ty.
-N.D.=not
detecGd(<rUaL)
]\,lQL=lvlethod
Quantilation
Limit
-Negative=Absene
or cr (VI):
'Positive=Presence
of Cr (VI)l
Uncedain=
can nolv€dfywhetherthe samplehav€Hexavalent
Chromium
by spot-test.
(The lerled sampleshouldbe tunherveified by boiting,wal€r+xtraclion
methodif lhe spot test resuttis uncedainol
sThe tesl is basedon the followi.gassumplion:
The sampteptaringis a singlelayerandeachpa( is unifom The testresult
maybecannotsrandior lh€ physicalttuth
ofsampteptating.
Photographof Sample
SHINZIIENAOVTESIINGTFCHNOLOGYCO.,LTO-KUNSHABRAI{CH
Ollo.tll.?,.""""
TestR€port
No.SHAEC1216714750
Date:25 Sep2012
Page'l ofs
ZHEJIANGASIAGENERALSOLDERING&BRAZING
MATERIALCO.,LTD
XIHU INDUSTRIALPARK,SANDUN,HANGZHOUCITY,ZHEJIANG,PROVINCE,
CHINA
Thgfollowing
sample(s)
was/were
submitted
andidentifed
on beharf
of thedientsas : LEAD-FREE
soLDER
WIRE
SGSJobNo.:
PartNo.(P/N):
Composition
:
Dateof SampleReceived:
TestingPeriod:
Te6tRequested:
- SH
sP12-028285
YTWl02 (692s39-002)
Sn2.0CuRE
21 9ep 2012
21 Sep2012- 25 Sep2012
Selectedtest(s)as requestedby dient.
TestMethod:
TestResults:
Pleasereferto nextpage(s).
Pleaseref€rto ne\4page(s).
Basedonthe performedtestson submittedsamples,lhe resultsof Lead,
polybrominated
Mercury,
Cadmium,
Hexavalent
cfiromium,
biphenyls
(pBB),
Polybrominated
diphenylethe6
(PBDE)
compty
withthetimibas setby RoHS
Direclive
2011/6yEU
Annexll; recasting
2OO2|95/EC.
Conclusion
:
Signedfor and on b€halfof
scs-cgTcLtd.
,z?r"'-
FanJinqjie,JJ
ApprovedSign€tory
rhb d@Dnr b rFr.c |r nr
k'{l efir
C.nddd.l6.rno
odd- osLd, w.r.l'lr 6Mnd
t n lle
u! a.Ddr'rE iq Eldimo o.uffi
. w*dh,|od
!l|dn. rry ndr..rttr'
rtr'eddr
d*dihndofidd
. t4. rn corulrr *
rybh
mh|trllltflunarl&i'.9ilob
fl'I|.*f,61'|r|db+3*ll
d..qrb
k
..d..llfu.h-.Aldfiriirmr;iitrffia
ri.blFondnnr
rmpr.(r, rnbd .
2o@q
fi:M
tn€Fa)filG60lEEiE-ArOSI9
rllj{E-ar)6140,,0att{fi-21l6ao@
*n.nrslcdn
.tdir&lilcn
Man!6rorrh€sqs olo!! (scs sA)
TestReport
No.SHAEC1216714750
Date:25Sep2012
Page2 of 5
TestResults:
TestPartDesciiotion:
Sp€oim€nllo.
1
SGSSampl€lD
Dcc,ipdon
SHA12-167147.043Sitvery
wire
RemarlG:
(1)1 mgftg=1 PPm=0.0001%
(2)IVDL= MethodDetedionLimit
(3) ND= NotDetected( < l\4DL)
(4) "-" = NotRegulated
RoHSDir€divo2011/85/EU
Testl\rethod: Withreferenc€
to IEC6232'1:2008
(1)Determination
ofCadmium
by ICP-OES.
(2)Determination
of Leadby tCp-OES.
(3)Determination
of Mercury
by |CP-OES.
(4) Determination
of Hexavalent
Chromiumby Spottest/ Cotodmetric
MethodusingUV-Vis.
(5)Determination
of PBBS/ PBDES
by GC-MS.
Te6t ltem(s)
Cadmium(Cd)
Lead (Pb)
Mercury(Hg)
HexavalenlChromium(Cr(Vl))
Sumof PBBS
Monobromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabrcmobiphenyl
Pentabromobiphenyl
!!!it
Ud!
10O
1000
mS/kS
mSikg
1000
-
mdkg
mgKg
mgKg
mgKg
mgKg
mg/Kg
ms/Ks
mg/Kg
mg/Kg
mS/kS
mgKs
mdkS
meyKg
1To 'nT
-
Heptabromobiphenyl
Oclabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Sumof PBDES
Monobromodiphenyl
ether
1000
-
l\4DL
@3
2
N
D
2
168
2
N
D
O
Negative
N
D
5
5
5
5
5
5
5
5
5
5
-
N
N
N
N
N
N
N
N
N
N
N
D
D
D
D
D
D
D
D
D
D
D
5
N
D
rn .dothr,$rLbhdtuFl
c!dr-/.
dnr ncr.|'ld
& qi.r rdta dsn-r
m.rr.ddaDlhMllln.d'lddtl.'
i'drbdn'l''hcd'c'|i&dcmdr.
h dr hi rPd
Dt' cir b,h. rm,
t'inr$r$fedrdrr6nl,gEidaorr
+l..t.t.lr6ldrl33oClstn
.b, hro
.
2o@3]
ll:M
ndhl. .rtrrhd
Fdr b. hnr.dm
lElE{S-Al6ia02563lElEls-a!ffiIg
rL{6-nl6|102ra rrlr{6-?r)5ae3
9w.64a.m
.€.d't!0.tM
.mb.rol rh. scs Goup{8Gs€ }
TestReport
No.SHAEC1216714750
Test ltem(s)
Dibromodiphenyl
ether
Tribromodiphenyl
ether
Tetrabromodiphenyl
ether
Psntabromodiphenyl
elher
H€xabromodiphenyl
ether
Heptabromodiphenyl
ether
Octabomodiphenylether
Nonabromodiphenyl
elher
Decabromodiphenyl
ether
udt
Lldl
ms/Ks
mg/Kg
mg/rg
mS/kg
mg/Kg
mg/Kg
mg/Kg
m9Kg
mdkg
Datei25 Sep 2012
upt
5
5
5
5
5
5
5
5
5
Page3 of 5
a3
ND
ND
ND
ND
ND
ND
ND
ND
NO
Notes:
(1)Themaximum
permissible
limitis quotedfromdirective
2011/65/EU,
Annexll
(2)
"spottest:=
Negative Abs€nceof Cr(Vl)coating,Positive= Presenceof Cr(Vt)coating;
methodif the spottest result
Cfhetestedsampleshouldbefurthervedfiedby boiling-wateFextraction
is Negative
or cannotbeconfirmed,)
oBoiling-wateFextraction:
Negative= Absenceof Cf(Vl)coating
Posilive= Presenceof Cr(Vl)coating;the detectedconcenhation
in boiling-water-extraclion
solutionis
equalor greaterthan0.02mg/kgwith50 cm. samplesurtac€area.
For@rosionprotection
coalings
on metals:Infofmation
onsto€geconditions
andproduction
dateof
thetestedsampleis unavailable
andthusresultsof Cr(Vl)represent
statusofthesampleat thetime
of testing.
n6.hffi
hft
*4dntuorrbrh
rrh..(.)r-rd.
f 6illselb'b.dld$0|..dlirdtqrr
lFt.-Ll.*tr6ltl€o!l6r}|
@
l|:a@3
TEEFZT)tll66! IBEFA)6*$,D
Hr (a-at614qer Hj F-a)fl@l
w6|a.M
. ttdhl&s@
M.m!.t olrhsaGsololp (aagsA)
TestReDort
No. SHAEC1216714750
Date:25 Sep2012
Page 4 of 5
ATTACHMENTS
RoHSTesflngFtowChart
1) Nameof the personwhomadetesting:
JanShi^/oyoWangr'A
enXao,caryXu
z) N€meortnepersonin chargeof testing:JeffZhang/ceorge
Xu/LindaLi
r) Inesesampres
w€redissotved
tota v bv ore-conditioning
methodaccording
to belowflowchart.(Cr6'
andPBBS/PBDES
testmethodexctudedi
Pb/Cd/Hg
PBBs/PBDEs
Aciddigestion
with
microwave/hotplate
Nonmetallic
matedal
1)AlkaliFusion/
DryAshing
2) Acidto dissolve
Filtration
andpH
adjustment
Addang
1,5diphenylcarbazide
for color
development
rn. .@md
e -.,r!!5ffi
I h.!d
byri.6oF
/ E[i-r
tu
&mil&hFd
b r. ord
codl|dr
b rm. rn c.dtu
rd.r[f,t
n6.hffi
6dr
oi s
k d
Ddod@nFr!.
Adding1,5diphenylc€rb€zide
for color
development
A redcolor
indicatesthe
pre6enceof cr6*. lf
necess€ry,
confirmwith
r.{dMrffi.
Thb drsrud
d!.r
b.6rmdr..d
*ror
6 nrr,$,l.d
N.ris,.4jwr
d tn.c.ffiv
bdnFdrhci,rb'brn!.h,'orc
ratUlle.|lrto
tr.hrt*€rthccfar
+l..ti.tiEEtufta9+sltt
tt:
zci@33
2r@s
lElE(6?r)6140at63tE!Et6{l)0'tE17t
m.6r€..m
.tasr'..Cc.6
EtB-?)6r102r1 iL(ri-?r)A!G3
Urmllr ol |h. AgAelou! (gGSSA)
TestReport
No.SHAEC1216714750 Date:25
Sep2012
Page5 of 5
Samplephoto:
sHA12-167147.043
reportonly
SGSauthenticate
thephotoonoriginal
"' Endof Report"*
tt-!,ruaYanbrrrr&id,$.'icti
+r'rr.*Jr8ltlsae'{33|t
2tEf3
3L M
tErEF.e0E
@ rEtE16*r)af5rr9
Hj{t-aldlML
fU0SAl)64e0
lrom!.r ol rh.8og Group(8G€S )
Test Report
Applicant:
Number : TWNC00282887
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Oct 31, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Filler
Part Number
: 091251
Date Sample Received
: Oct 24, 2012
Date Test Started
: Oct 25, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
*THJ0282887*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 1 of 7
Number : TWNC00282887
Test Conducted
(Ⅰ) Test Result Summary :
Result (ppm)
Submitted Samples
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Oct 24, 2012
: Oct 25, 2012 To Oct 30, 2012
*THJ0282887*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 2 of 7
Number : TWNC00282887
Test Conducted
(Ⅱ) RoHS Limits:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from Annex II of 2011/65/EU for homogeneous
material.
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
Reporting Limit
*THJ0282887*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
2 ppm
2 ppm
2 ppm
1 ppm
Page 3 of 7
Number : TWNC00282887
Test Conducted
(Ⅲ) Test Method:
Test Item
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Test Method
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MS
and further HPLC-DAD confirmation
when necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MS
and further HPLC-DAD confirmation
when necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by Ion Chromatograph.
Reporting Limit
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
*THJ0282887*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 4 of 7
Number : TWNC00282887
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
*THJ0282887*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 5 of 7
Number : TWNC00282887
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
bomb at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions
governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this
report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by
statute or otherwise, except in the event of our gross negligence or wilful misconduct.
*THJ0282887*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 6 of 7
Number : TWNC00282887
Test Conducted
Photo
*THJ0282887*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 7 of 7
,fl.d,+E+
TestReport
trTxlt*.5G
nown
ForOue5ll
PleaseCo
ithscs
f i , S ( N " . ) , c E / 2 0 1 2 / ] 0 8 3 5 E 4 ( D a t e ) : 2 0 r 2 l 0 1 / 1 1 F & ( P a 8 e ): r o f r o
ELSCHUrcMELEKTROSCHUTZI{OMPONENTENBAU
GIIBH
CEI'ERBESTR,ASSE
87, D-98669 \EIISDORF, GE&UA\Y
ideltified
Validit
68P 't&, -R& *,P +*&lf*P
hylon behatf of rle client
iiSZ,f*(s.'pl" D€s.ripr ion)
if gd&(style/I r€b N".)
4 , & . E ( c o u n t i y" f o r i s i n )
{t4 A S (s.'!1" Rec€ivingDate)
,tlHS&l(Tesrihc P€.i od)
ji,t,+ jR(rest Resrlts )
'
|l]
*AnT
(The folloeins
saDples ra./rcre
srbeittcd
t|| fl m
and
as):
SILIER
PIATED & PURE SILVM
$'IRES
',tr+*sR
(PLEASEREFERTo PAGEs)
(GERI4A\"Y)
{EE
2012/0t/04
2 0 1 2 / 0 t / 0 4 ' f o2 a t 2 /a t / t l
5 + X .F - F { P r e a , e r e f p - r o r e x r ! a s c ! r
(Alw4?\
C$Fdft.|nd
chrnLd lrbor.tlry - Trlpd
?
r'-;.!liiri
i
.:
i
).:!tli
p3G)6rad rb s rad Gpon€n'orF
ir. r.r rl!tul.
McmbForfie !69 Gouo6c! Sr,.r
,fla,+E+
TestReport
! t 4 5 ( N o .) : c E / 2 0 I 2 l l o d J s
E q ( D a r " ) : 2 0 1 20 I / l l
E*{pase) ,2 oi l0
ELSCHUKOM
ELU(TRqSCHUTZXOMPONENTENMU
GVBH
GENERBESTI{ASSE
87, D-98669'IIEIISDORF,CE!.T{Ar\Y
It**(T.st
]||lt[ttl||||fiml|!
R e 6 u lt s )
jrl:i *r'.i (PARTNAME)No.l :
ie;qma&ein&
(6{t,r)
(Jt6t ) (MTXED
ALLmLoRtltErArNrm
( INCLUDINGTIiE PLATINC LA\'ER) (6 TYPES))
r|iiit E
ttt.ttrl
Etl{N
*ittri
+lt
(Urit)
,fr / cadniun (cd)
(rDL)
+arEc 623zLt2oo8r;i, 4&,S*{
6€*.F+&4t*.*d,h;Fl.
/ q'ith
refe.ence
perforfted
S
/ Lead (Pb)
to IFC 62327t 2008 anl
6y ICP-AFS.
++IEc 6232rt2008ti1, rr t$A*t
+t*fr+**i*,;*d&;il.
/ {i ih
.eference to IEC 62321: 2008 and
by ICP-,ES.
terforaed
*- / vercury (Hs)
: 2008t&,'r€E*4
++ lEx.62321
+€ {/F + **t rt ;* d,*birl. / $i r1'
reference to IEC 62321: ?008 and
perforned by tCP-r{XS,
,i.flJ'
/ Heaav,lent chroni!n c.(vI)
++ \F: 62321.2OO8li*, t)a.,fr
*+
/ with fefe.€n€e ro IEc
RliAtll.
6 2 3 2 1 . 2 i A B a n d p e r f o r m e db y
B o iI i n s s a t e r e x t . a c t i o n M € t h o d . #
}fr.+B**
sulfonates
/ Perrruo.oocrane
nglka
(PF!S-Acid. Uetal salt
t+us
EPA3540C:1996tii, 'lil
IO
iE,9*f1[-r*&}f,4
an+,t,4*69'
/ t r i t h r e f e r e n c e t o u s E P A3 5 4 0 c
1 9 9 6n € t h o d f o r P F o SC o . l e . l .
Analysis was perlorned by tClMS.
an+6.(J+) / PFoA(cAsNo.: 3356?
r)
++US EPA3540c:l996tt!,
,Xtl
&Eif 1{r*{,*fl an+d(n) }f
/ w i t h r e f e t e n c € t o U S E P A3 5 4 0 C
1 9 9 6e e t h o d f o r P F O AC o n t e n t .
Analysis was perfofned by rc/MS.
i j :i :r l , ]. r : . a i i . ; ; r t i ]
c o n o a .t y r r , : 1 r 1 , ri!' _, r r l - J n
iy $qd rob cene6cdidroc d s
onlysndwibinlh.imlsoic€nls'ns
pelsr reded rhE bd rcpod Enid be
1, . r, rjr,!*.
l0
s*
(Resql t)
No,1
rfla+E+
ft4(No.) : cE/20I2lr0835
Test Report
E J q ( D a r :e2)0 t 2 l 0 t
E * . t e , B " ,/ 3 . r
ELSCHUKOM
ELEKTROSCHUTZKONPONENTENBAU
CMBq
GMERBESTRASSE
87, D-98669 !'EIISDORF, GERMAIr\
d{t
E
lll
+4o
,{fi,t*
( U n it )
( R e s u1 t )
(IDL)
No.l
/ uonobronobiphenyt
:;Ad*
qA#tri
/ Dib.onobipltenyl
/ T r i b r o n o b ip h e n y l
/ T e t r a b r 6 n o bLo h e n v l
I*#Xi
/ P e n t a b r o n o br o h e n ! I
/ Hexabronobiphenyl
?!4$it
+iASf
/ H e p r a b . o n o bpi h e . y 1
^itrfi A / o.rabronobipheDyl
/ Nonabromobipheryt
4)qS*
/ D e c a b r o n o bpih e n y t
+;ASf
*trEc
/ suo of PBDES
t*AS.t&t"
-;ASf!{
/ M o n o b r o n o dD
i hehvl ether
=-r[#*e
:;A#+a{
/ D i b r o n o d ip h e n y l e t h e r
/ ' l r i b r o d o d i p } e n v l er h e .
B,*SiFa*
/ Tet ra6.onodi phe.vl erher
i;*Sxad
'r*S*a*
/ P e . r a b r o m o dDi h € " v l e t h e r
/ H e a a b r o n o dpih e r v t e r h e r
-k;A#Xa{
/ H e p t a b r o m o d iD h € n v l e t h e r
,\;*SXa{
/ o c r a b r o n o dD
i he.vl ether
,L;i#*e
i henvl etler
i N o n a b r o m o dD
+&#ii4
/ D € c a b r o n o d i D h e n velt h e r
623211
zoo$iiF, ,tfu|aE
+8dlf :*d,&jrl. / $ith rererence
ro IEC 62321:?008 and perforned
by rc/MS.
5
5
5
5
5
5
5
5
5
5
5
5
5
5
a* / s"l.s."
(fr.) / Halogen-Floo.ine(F) (c{s
6*
No.: 14?6?_94-8)
(5.) / Haloeen-chlo.ine (cl) (cAs
6*
! o . : 2 2 5 3 71- 5 - r )
& * ( * ) / H a l o r e n - B r o n i n e( B r ) ( c A S
l{o.: 10097-32-2)
50
ng/18
vx&+8fr
ltBs vt r4s82:2007,
50
/ sirh reference to Bs EN
{r}*t.
I 4 5 8 2 r 2 0 0 7A. n a l y si s v a s
50
(I) (cAS
6fr (dU / Halocen-lodine
No.: 14362-44-8)
conFiv;"
r 1 llu.,[r'r,
l: i/irr.r I i.tl
lt!,lr'i
oyglbredbb6ai.'alcondloisds
50
hrr.(s) rssbd rh s resr €pon ennd
lLr Lt[]!.
iq
3pdJb't}6lobc€da^dhsdocu
b
r**
,illt,rl
EIE{I
/ su! of PBtss
t*t**'ts
:14#*
:i*#f'
(Iethod)
ro
l ]tl|
]t
,F{a+E+
ff6(No.)
Test Report
: CE/2012l10835
aBlJzr.)
. 20L2/ot/71 Ftk(pare) : 1 of r0
EI-SCHIrXOI1I
ELEKTROSCHUTZ(oVPO|iENTU\]BAU
GttBH
GEI/ERBE.STT.ASSE
87, D,98669 VEITSDORF.GERVIIY
[]tl||t][]tI|
fiii(N.t.):
l . m g l k g: p p m ;0 . | w t %= l o o o p p n
2 _ n _ d . = N o r D e t e c t e d( * . t A r r )
3 - M D L: M e t l o d D e t e c t i o n L i r i i ( r l t l A ; { t s 1 8 1 6 )
4. '- = Not R"sulated (Sli,+&.6)
5 . r ' = Q u a t i t a t i v e a n a L y s i s( N o u n i t ) _ € , B r ) * f ( * + & )
6. #:
a . P o s i t i v e b e a ! s t l e p . e s e n c eo f C r V t o n t h e r € s t e d a r e a s
(po s i t i ve *,F rq,lit E q.tF jq r{ ,r{l rS)
b . N e g a t i v e n e a n s t h e a b s e n c eo f C i V I o n r h € r e s t e d a . e a s
( Nesat i ve i nr::tl*, E 4 t.tA ).14 'r1l1g )
T h e d e t e c t e dc o h c e n r r a t i o ni n b o i l ] n a - e a r € r - e x r r a c t i o sno l u t i o n i s € q u a l o r g r € a r e r t h a b 0 . 0 2
m A l k gw i t h
50 cn: tested ar.a". / li6;i{XA>0.02
nslka *iih 50 cm, (tested
z. tte.i,tlS{r.'Af
;F./.**isArxl:{,, *E+titi,sA,tt:ri}:+.Tftt 4 +1Erll+-ttlt aiAE.
(The sanples sas/were analyzed on behalf of the atfricant
! e s u l t s w a s / w e r eo n l y g i v e n a s r t e i n f o . n a t i t y v a l u e , )
PFos++*d,(R"f
Inf orlation)'
"'.o"€
(1) riitrrf rTfi.'|tsld.&n,r+r+4rrf,
as mixing sanpre in one resrine.
The above
!A+ 2oo6trzztEa (Di rect iae 2006/t2ztw)
d.Ee,Ed,rlE*tla+,i6d.n,+0.
005%.
(May not be placed on the market o. used as a sDbstance o. consrituent
€qual io or nigh€r than 0.005 % by nass.)
of prepararrons
(2rtit{ttX4n&*fi&}.ei+d."%d.6s{.*{r1+;1!i*€1+}aX*Jt+ApFosi.4t?J*fi}.e.t&r€t6€};l4pFosEE
,i.&+,i!d.i,ifo.r%,6*r&€d.4{tti.4rf. {,RprrsaAt*f + 6E*;Ad.Ji;Aruc/.,.
(Maynot be placed on ihe na.k€t in seni-linisned prodocts or articles, or pa.ts rhereof, if
ure
c o n c e n t . a t i o n o f P F O Si s e q u a t r o o r h i g h e . t h a n 0 . 1 % b y n a s s c a l c ! l a t e d s i t h r e f e r e n c e t o t l e n a s s o f
s t . u c t u r a l i y o . f r i c . o s t r u c r u r a l l y d i s r i n . r p a r r s t ! a i c o n t a i n P F o . so r , f o . r e x r i t e s o r o t h e . c o a r e d
naterials,
if thc anoun! of PFOSis equal to o. hiahcr than Ug/nr of thc coated nateriat.)
c o m p a ityr : ; r , r ; : i r l , , ; - f i t . r l J r . n i r r , . r , , t i i
Ltlttr
1i., r".l,r!/,)!
ont andub'n ihsh b orc en'3,ns
-.4ttr
- ! . ! , , : r r i r l l i - I. c i e o a F i
-:.r ;::rlnti,,;i+46iDr,ssr7
l
,rla#+
TestReport
ft,q(No.) : cE/20r2lr0835
E S ( D a t e ) : 2 0 1 2 1 0 1 / 1 1F * . ( p a s € ) : 5 o r l 0
EI-SCHIXOi,I
ELEKTRO€CHUIZKNTPONENTENMU
CVBH
GEIIERBESTInSSE
87, D 98669 IEIT,SDORF.GERILUY
tl&4!t(styl./I
[t[t
t.' N".)
(B-1) 101. 014
-silver
plated coFpe.{tre-Cu. Ag - - %
(B-2) 101. 0131. - - - - -pure silve. sire-Ag l()()()
( B - 3 ) 1 0 1 . 0 1 2 3 . 0- - - - s i l v e r
platcd purest nickct vire-Ni99.98%. AgI%
-silve.-copper alloy plated cotpe. clad vire-Elcon D,
(B-4) 10r,0182.0 - -silver
(B 5) 101.0120.0
p l a t e d c o n s t a n t a nw i i € - C u N i 4 4 , A A S %
( B - 6 ) 1 0 1 . 0 1 5 1 . 0- - - - c o p p e r - n i c k e t 4 4 a l l o y s v e r p l a r e d s i . e - c u N i 4 4 ,
c o D o a n tv l r I t ! . , r - N ' | , r " l : l , i l l l i
:. ! 1 1:;!1,1\
p sG)rssr€drh s€d Gpon€ind e
rlllrillrl.
!
ont 3nd*ii'n rh. hrs or c €nr s 'ns
ri.:l,;l-":Iq:j1
tl|
|||ll
,fl-d,#+
Test Report
f i { 5 ( N o . ) : C E l 2 0 1 2 l l o s 3 s E S ( D a r e ): 2 o t z l 0 r / t t F # ( p a s € ) :
ELSCHUI{OM
ELEKTROSCHUTZKOMPONENTENBAU
G\!BH
GEWERBESTRNSSE
8?, D 98669 WILSDoII, CERMA\Y
6
0 f l 0
[l|[]|l
r) ll?cr,-F $,EEn zI*1+ ' *.& aia*t+
. ( *1' j&d *tt *hrl. ) / Thes€samDtes
!,€€
d€sotuedrolrrryby p.e-condrumhgmethooaccodinglo betN nowchad. cP re€tmethodexcludeo
2) r.lri^l:
yang
$e ! / Naheotlneps6onwhomadenEsuremed:ctimbgreal
3) ir'13{I i ^ : tl4* / Nameof the pe6on in chargeormeasu€m€nlrTroychans
tr*. {rtt*s
/curing. p€galaton
iqr{.&,cf ! / sdde MeasuEmenl
&lf;F n l*'.g6tt{ f, 6 }xn!trai&it,tirt /LoeTt
4rt/!inlt n.i'la{&,aib /
4,;) /Acid dig€slion by suitabte acid dependedon
dtrerenlsahdemaledat{asbetowiable)
MiorcMve digestion with HNO3/HC|/HF
,"rl4rOf jit& jt.li,lilt +
C( / H€i to appropriate
1)
2)
f [*a{*4+*it{rtc
/ AlkaliF6ion
/HCltod$d€
/ rcP,aEs
f!911L / samdeMatedal
51eel,@pper,allnirum, solder
&ltgti
ta{*tt
;filt&AJlfi / DiqesL|onAcd
-t+, 4la{,!lt, nn*, el,,k /
Aa@ reoia. HNO' HCl. HF. H,O,
rra{,Inc / HNoJftF
A, J6,€, nit /
Gold,olalinum,
Dalladium,
ceramic
,i(f rf 7h-ir,g t.rLrlf,.' I
irl#B*i{Aftrcnm 6id
rti!€ /HNOr
&E / Plaslic
4?,*i&8tt$ / coot,
fherdigestate
lhrough
liher
*d, t{"*,
s!t, td / H,so. Ho,. HNorhcl
,! \'efi*1eti*l+
/ Anyacldlo lotaldig€Gtion
j i i r i r +
r i l , i ,
! . r 1 r . t p . l i , . 1 , i f i ' ! ! l .
rhcdddneiiAs€dbysgcompa^ys!b4d{ob6ai..a|condloi3ds
ab6o6anceat a/ronmby
UV-VIS
t]n]l
,F{a*R+
Test Report
iEIS(No.) : cE/2012l10835
E rr?(Dare) : 2012l01/11 F&(P,s")
ELSCHUKOMELEI$ROSCHUTZKOIIPONENTENB,qU
GMBH
CETERBESTRA.SSE87, D-98669 VEIISDORF, CER[{AI\'Y
t ttt*/t
rtt+4+f
l
*,aE / PBB/PBDE
anatyticat
FLOWCHART
a }l{,/\l
I a_i9*, / Nameoftheperson
whomademeasuremenl:
RomanWonq
r,$Ji( frt ^ : &+le / Nam€of thepersonIn chargeof measurement
TrcyCha;g
n^ ld,ElF / Firstlestry proce.s------------f
....,---.
prccess
€*,E&*€F / OptionalscE€n
-. -,t
*{.€,S / Confimation
orccess
:l
Scre€n
analysis
/ ,, rfi+rt
I
I
sample
erlraclion
*s+*/
Soxhlet
melhod6i,+tx;*
Concentrale/Dilute
Enractedsoluiion
+tri{ rira/ifi#
Filter/ +S.i{'E.d
Analysis
byGC/MS
/ fr"ian&f ie*,+&
*irl+
c o m D a n +! " , I
rirr,,: i;
r. lJ: ?.lria 1.:-!i
-j!,AlrI
3u!,0db'.ms,idcoidsdislolE
pslsl bdad h€rad cpod€nnorb3
i.,.-l:r311.!
|
|
t
l||tI
l
rF{-d,+E+
Test Report
f t 1 4 ( N o . ) , C E / 2 0 r 2 l 1 0 8 3 5E S ( D a r . ) , 2 o l 2 l l ] t / t t
F&{prse)
EI.SCHUI(OM
ELEI{TROSCHUTZ(OMA)NENTENB,{U
GVBIi
GE9ERBESTTASSE
87, D 98669 \,'EIT-SDoRF.GEf,Vl}IY
it+&fiAn
I
I
Il]tIltt][||||[|!
/ Analyticalflowchartof halogencontent
jtli{,l.F : gi',g* / Naneof thepersonwhomademe€surement:
RitaChen
jrl:i,A ll, : #,*e / Nameof thepersonin cbargeof measurement:
TroyChang
*+E &t&.'sl'I
Analysis
wE6perfomedby lC
.Iir
Th s ddfuh.il
s '$u€d bl ft
np61s) rssbd fu bn cpod €nnor b
i.'.iiri:llr
it
Li
ii'!r]-l
i -1"j! :
pa
c om
3 l b j e d b ] e m s a i d c o i d l o n s f o r E A t a ^ l o n 6 d d n l o f t ] m l a t o n d s b l t y
.;.: r.r- i.1-]ii1
r,r+ s6iorre
rD r+ s6 Lo?lrrenr
wwslon
ilts,#+
TestReport
it4(No. ) : cE/2012l10835 AS(Dare) : 201210r/tr
F*.(pase) : 9 of lo
E-SCHUKOM
EI-E(TROSCHUTZKO]\IIONENTEN&{U
GMBH
GEFERBESTRASSE
87, D-98669 VEIISDORF, CERMA]\ry
tI|fll|t][taf,
*Ji+n+fin€n /
Analyticalflow chartofSoxhtetextraction(LC/MS)procedure
r
r
i A/-F : ij!9*y / Nameofthe personwhomademeesuementRcmanWong
t4j:{, q i,\ : tF'.*4 / Nameof the personin chargeof measurement:
TroyChang
( rd8,{ a : Afi.+n*.n/Afi.+rt(*)
, **.:4i{bA4,
Test ltems: PFOS/PFOA. Benzotriazole)
*{*
cmpanyr:i r , tr 'ri_ll i ,r'"'ll:l ill+
r. r i rtirril: .
/ Datia
p3G)r8sbd
rh s rsd,epon
€inore
-. '.- it!,1 .
pdisb ,9 a b b cr ed and ih s dotum
/
l
trl'd,#+
TestReport
fi6(N". ) , c-E/2072/10a35
Es(Date) : 2tr2/ar/r1
E*@aEe) : r0 of t0
ELSCHTJKOM
ELENROSCHU'\ZKOMPONENTENBAU
GMBH
GEISRBESTR.ASSE
8?, D.98669 WII-SDOTF,GERVA}Y
trlt[tl
+ ffifi tr'6*t*i
' Fl* ftfrfl*lt,rlz{tsi
(The tested sanple / part is narked bt an arror if
ir's
1083s
10835
** lE+344.(E"d of Report) ++
i:. j:r.i | ,.tll
itt: I
c d h p , i in r . i ' , r , " r i l ' i , ,
rhsdoarudE 3s!sdbyhe.omp,^yeqedb G6erydcodromor s
+ *ri.*irr !r. i r,.
l6en,a r,p.
'
..
. !,r:L!.
${i'
t
shorn on rhe photo.)
fl|||trr
nov'
TESTREPORT
NO.:4002E11121307-2R02
page1of4
Oa!aiDec15,2o11
Customer:SuzhouFuHongElectrcnic
IndustfialCo,
Ltd.
Addrgs8:NO.89WElDUROAD,WANGTING
TOWN,
XTANGCHENG
D|STR|CT,
SUZHOU,
CHTNA
Reporton th6 3ubmittedssmplesaidio be
Samplename:Fusoscoppershell
llodol: /
Material:/
D$cription:/
Buyea:/
supplier:/
Sa|nplerecelveddate:Dec.13,2011
Tcatlngp€riod:FrcmDec.13,2011
to Dec.15,2011
T€tino Reau6ted
As specined
by client,to delermine
theL€ad,Cadmium,
Mercrry& Hexavatent
Chrcmium
contentin thesubmitted
samptein
accordancewilh Direclive2002/95/EC(RoHS).
Tcstindmethod:
Testing llem
[,leasudng
inslrument
MQL
Lead (Pb)
EC 62321:2008,seclion9
ICP-OES
2mglkg
cadmium(Cd)
(Hg)
Mercury
EC62321:2008,sectionI
ICP€ES
2 mg/kg
EC62321r
2008,section7
rcP-oEs
2 mg/kg
(Crl'I)
Chrom'um
EC62321:2008,
AnnexI
0.02mg,a(g'
lsg
-'0.02mg/kgreturs
10lheMQLofsample
extEction
tiquid.
99!s!.c!i9!j
-ffien tesiedas specifred
thesubmitted
sample
complied
withtherequircments
of commission
Decision
of 18Aug2005
amending
Directive
2002l95/EC
nolified
lnderdocument
2005/618/EC
ILS, PLEASEREFERTOTHE FOLLOWINGPAGE(S)'**'
',:,"il:::i"
ryf4
,3ffi::::1,,44
hrn
lffH*"",",We-i
S}'EI{ZN€N AOV TGSTINGT€CHNOlOGY CO.,L'D.KUNSHAN EiANCH
Hotllne
86-512-551
80 0 0
nov
6
TESTREPORT
NO.:4002E11121307-2R02
Add the digestionsolution;the
vesselis heatedLrntillhe sampl€
AddHrO,unlilthesampl€is clear
F;;1.-F;;,",..;-1.-
Cooling
thevessel,fllleriwashedand
filledto themarkwithdistilled
water.
{Melalsubslrat€)
Add lhe digestionsolution,clos€
The sampleis digestedin the
the macrowavevess€|.
micrcwave oven following a specific
program.
decomposilion
Coolingthe vessel,filter washedand
filled to the mark with distilled water.
Remove
thesample,
andcool
lhe beakerlo rcomtempefalure,
anddo1ie colorreaction
Heal50 mL ofDlwaterin lhe
beakertoboilingfor 10 min
Testthesamplesolution
andlhe 0.02
mg/kgstandard
solution
by UV-VIS.
To Detemine
(Praring)
andl\rercury
Content:
coor,ns.
nrr",
*""n"0 r"o
_____-l
""0 |
I
tothemark
withDtwater
I
,l o*o
-ill_.;*--;-l
I r*r.r*t
|
STIENZH€NAOV TESIING T€CIII{OLOGYCO.,lIO,KUII9HAN BFANCH
Hdpi/j,w.o{,6n
|
-.-
|
Hotline
8 6 - 5 1 2 " s 5 18 0o O 0
nov.
TESTREPORT
NO.:
4002E11121
307-2R02
Date:Dec.15,2011
Page3 ol4
5. ToDetemineHexavalent
Chromium
Contentln
colorless
andcolored
ctlromate
coalingon metals: (Plating)
'' ',.'1
re$eoovr I r
s.t sw-resi (M&
lflhe lest resullis positive,
the sampleis considered
1o
havehexavalenlchromium
Boiling- waieF extraction
procedure
shallbe usedto
and the 0.02 mg/kg
lfthe€ isrnterference
orI rshardto decide*terhel
lhesamplehavethehexavalent
chrcmium
5 2 BoilingwEter-en€ction
Takethe (5015)cm'z
samplein thebeaker.
Heat50 mlof Olwaterin the
beaker
lo boilingfor 10min
Remove
he sample,
andcool
lhe beaker
1oroomtemperature,
anddo thecolorreaction
Testthe samplesolutionand the 0.02
mg/kgstandardsolutionby UV-VIS.
Srmple d93cription:
Coppershellsubslrate
Leadwle Platrng
Unil
24
CoppershellPlaling
RoHS
Limit
2-3
24"
Lead(Pb)
mg/Kg
1000
N.D.
2.5
40.0
N.D.
Cadmium
{Cd)
mg/kg
100
N,D.
N.D.
N.D.
N.D.
(Hs)
Msrorry
(Crvl)
Chromium
mg/kg
1000
N.D,
N.D,
N.D.
N.D.
mg/Kg
1000
Negative Negative Negalive
Negative
SH!NZHEN AOV TESTINGTCCTNOIqGY CO.,L}D,KUNSHAN BFANCH
n
Hotline
86'512^551
80 0 0
nov.
TESTREPORT
NO.rA002E11121307-2R02
Dat€iOec15,2011
-The new RoHSdi.ective2011/65/EU,
on Jul 21, 2011comeinto force,on Jan.03, 2013the fomat imotementation.
Dircctive
2002l95/ECshallbe reoealedsimultaneouslv.
Sp€cim€ns,wnicnrequestedto determineLead,Cadmiumand l4ercuryConlent,havebeendissotvedcomptetety.
-mg/kg=ppm
-N.D.=notdetected(<tVoL)
-MQL=l'rethodOuaniilationLimit
-Negalive=Abs€nce of Cr (VI);
Posilive=Prcs€nce
of Cr (VI)i
Uncedain=c€n noi ve fy whetherthe samplehaveHexavat€nt
Chrcmium by spoliesl.
(The tested s€mple should be furlher venfed by boiling-waterextradion
method if the spol test result is uncertainor
-'The test is basedon the followingassumption:Thesampteptatingis a singtetayerandeach pad is unifom. The test resutt
maybecannolslandior rhe physicartruthof sampleplating.
Photog.aphofSample
"'End of Repod"'
S'iE'!ZH€N AOVT€STING TECXNO!OGYCO..lIO,KUNSHAN ABANCH
Hh,:/fuloi6n
n
Hotline
86-512-551
80 0 0