Download Data Sheet

TECHNICAL DATASHEET
Rev B
JFCW48S12-1300
15.6W DC/DC Converter
18-75 VDC Input
12 VDC Single Output at 1300mA
Features:
Applications:





UL
TUV
CB
CE MARK (Pending)
Measurement
Telecom/Datacom
Wireless Networks
Industry Control Systems
Semiconductor Equipment
Options:




Trim Function
Negative Remote ON/OFF
ON/OFF Control Function
Heatsinks Available for Extended Operation

RoHS Directive Compliant

1.3A Single Output Current

Industry Standard Pin-out

No Minimum Load Requirement

15 Watts Output Power

Adjustable Output Voltage

High Efficiency up to 87%

Low Profile: 1.0 x 1.0 x 0.39 Inches

Input to Output Isolation: 1600VDC min

4:1 Ultra Wide Input Voltage Range

Fixed Switching Frequency

Input Under Voltage Protection

Output Over Voltage Protection

Over Current Protection, Auto-Recovery

Output Short Circuit Protection

Remote ON/OFF Control

Six-Sided Shielding
Description:
The JFCW48S12-1300 is a single output DC/DC converter that provides 15.6 watts of output power
in an industry standard package and footprint. The JFCW48S12-1300 is specifically designed to
meet power needs in a low profile package. This model features a 4:1 wide input voltage range of 1875VDC as well as positive or negative remote on/off, 1600VDC I/O isolation, and trimmable output
voltage. This converter is also protected against over current, over voltage, input under voltage, and
short circuit conditions.
(888) 597-WALL
www.wallindustries.com
Page 1 of 14
TECHNICAL DATASHEET
JFCW48S12-1300
Rev. B
Technical Specifications
JFCW48S12-1300
Model No.
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT (Vin)
Operating Voltage Range
UVLO Turn-on Threshold
UVLO Turn-off Threshold
Input Standby Current
Input Current
Input Voltage
Input Voltage Variation
Reflected Ripple Current
Start Up Time
(Nominal Vin and constant resistive load)
OUTPUT (Vo)
Output Voltage Range
Load Regulation
Line Regulation
Voltage Adjustability (see page 5)
Output Ripple & Noise (20MHz)
Output Current
Output Voltage Overshoot
PROTECTION
Over Voltage Protection
Over Current Protection
Short Circuit Protection
DYNAMIC LOAD RESPONSE
Peak Deviation
Setting Time (Vout < 10% peak deviation)
REMOTE ON/OFF
Negative Logic (Option)
Positive Logic (Standard)
Remote OFF Input Current
Input Current of Remote Control Pin
GENERAL
Switching Frequency
Efficiency
ISOLATION
Isolation Voltage (Input-Output)
Isolation Voltage (Output to Case)
Isolation Voltage (Input to Case)
Isolation Resistance
Isolation Capacitance
ENVIRONMENTAL
Operating Ambient Temperature
Operating Case Temperature
Storage Temperature
Temperature Coefficient
MTBF
Bellcore TR-NWT-000332, TC=40°C
MIL-STD-217F
MECHANICAL
Weight
Related condition
Nom
Max
Unit
18
48
75
18
Vdc
Vdc
Vdc
mA
mA
16
15
Nominal Vin and No Load
Nominal Vin and Full Load
Continuous
Transient (100ms)
Complies with ETS300 132 part 4.4
5 to 20MHz, 12μH source impedance
(See the Test Setup section - pg 9)
Power Up
Remote On/Off
Nominal Vin and Full Load; Ta = 25°C
0% to 100% Full Load
LL to HL at Full Load
All models
Measured with a 1μF M/C and a 10μF T/C
(See the Test Setup section - pg 9)
392
75
100
5
30
11.88
-0.2
-0.2
-10
12
0
LL to HL at Full Load and 25°C
voltage clamped
All models
All models
Test at nominal Vin
Load step change from 75 to 100% or 100 to 75 % of FL
Load step change from 75 to 100% or 100 to 75 % of FL
The ON/OFF pin voltage is referenced to -Vin
(See the Remote ON/OFF Control section - pg 6)
DC/DC ON (Short)
DC/DC OFF (Open)
DC/DC ON (Open)
DC/DC OFF (Short)
0
13.5
ms
12.12
+0.2
+0.2
+10
Vdc
%
%
%
100
mVpk-pk
1300
3
mA
% Vout
19.6
Vdc
150
% FL
Hiccup, automatic-recovery
0
3
3
0
mV
μs
1.2
15
15
1.2
-0.5
1.0
Vdc
mA
mA
kHz
87
%
1000
-55
-0.02
Vdc
400
1600
1000
1000
1
-40
V/ms
30
30
300
250
All models
Nominal Vin, and full load; Ta=25°C
(See the Test Setup section – pg 9)
Vdc
mApk-pk
2.5
85
105
125
+0.02
Vdc
Vdc
Vdc
GΩ
pF
o
C
C
o
C
% / oC
o
See the MTBF and Reliability section (pg 13)
1,330,000
hours
563,000
hours
See Figure 1
15 grams
1.0 x 1.0 x 0.39 inches
25.4 x 25.4 x 9.9mm
Dimensions
(888) 597-WALL
Min
www.wallindustries.com
Page 2 of 14
TECHNICAL DATASHEET
Rev. B
JFCW48S12-1300
Figure 1: Mechanical Dimensions
Unit: inches (mm)
PIN CONNECTION
PIN
SINGLE OUTPUT
1
+ INPUT
2
- INPUT
3
ON/OFF
4
+VOUT
5
TRIM
6
-VOUT
1. Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance: ±0.01 (0.25)
3. Pin dimension tolerance: ±0.004 (0.1)
EXTERNAL OUTPUT TRIMMING
PRODUCT STANDARD TABLE
Option
Negative Remote ON/OFF
Positive Remote ON/OFF
Without ON/OFF pin
Without ON/OFF & TRIM pin
Negative Remote ON/OFF without TRIM pin
Positive Remote ON/OFF without TRIM pin
(888) 597-WALL
Suffix
R
No Suffix
D
G
RF
F
www.wallindustries.com
Output can be externally trimmed by using
the method shown below.
Page 3 of 14
TECHNICAL DATASHEET
JFCW48S12-1300
Rev. B
DESIGN CONSIDERATIONS:
Output Over Current Protection
When excessive output currents occur in the system, circuit protection is required on all power supplies. Normally, overload
current is maintained at approximately 150% of rated current for the JFCW single output series.
Hiccup mode is a method of operation in a power supply whose purpose is to protect the power supply from being damaged
during an over-current fault condition. It also enables the power supply to restart when the fault is removed.
One of the problems resulting from over current is that excessive heat may be generated in power devices; especially
MOSFET and Schottky diodes and the temperature of those devices may exceed their specified limits. A protection
mechanism has to be used to prevent those power devices from being damaged.
Output Over Voltage Protection
The output over voltage protection consists of an output Zener diode that monitors the output voltage on the feedback loop. If
the voltage on the output terminals exceeds the over voltage protection threshold, then the Zener diode will send a current
signal to the IC to limit the output voltage.
Short Circuit Protection
Continuous, hiccup, and auto-recovery mode. The average current during this condition will be very low and the device is
still safe in this condition.
Input Source Impedance
The power module should be connected to a low impedance input source. Highly inductive source impedance can affect the
stability of the power module. Input external C-L-C filter is recommended to minimize input reflected ripple current. The
inductor is simulated source impedance of 12μH and capacitor is Nippon chemi-con KZE series 10μF/100V and 10μF/100V.
The capacitor must be connected as close as possible to the input terminals of the power module for lower impedance.
Thermal Consideration
The power module operates in a variety of thermal environments. However, sufficient cooling should be provided to help
ensure reliable operation of the unit. Heat is removed by conduction, convention, and radiation to the surrounding
environment. Proper cooling can be verified by measuring the point as the figure below. The temperature at this location
should not exceed 105°C. When operating, adequate cooling must be provided to maintain the test point temperature at or
below 105°C. Although the maximum point temperature of the power modules is 105°C, you can limit this temperature to a
lower value for extremely high reliability.
Figure 2
TOP VIEW
Measurement shown in inches (mm)
TEMPERATURE MEASURING POINT
(888) 597-WALL
www.wallindustries.com
Page 4 of 14
TECHNICAL DATASHEET
Rev. B
JFCW48S12-1300
Heatsink Consideration
Equip heatsink for lower temperature and higher reliability of the module. Considering space and airflow is the way to
choose which heatsink is needed.
Figure 3
Unit: inches (mm)
Output Voltage Adjustment
Output voltage set point adjustment allows the user to increase or decrease the output voltage set point of a module. This is
accomplished by connecting an external resistor between the TRIM pin and either the +Vout or -Vout pins. With an external
resistor between the TRIM and -Vout pin, the output voltage set point increases. With an external resistor between the TRIM
and +Vout pin, the output voltage set point decreases.
Trim Up Equation
Figure 4
10,000  2.5


Rup  Vo , up  2.5  9.5  5110 


Trim Down Equation


(Vo, down  2.5) 10,000
 5110
Rdown 
Vo  (Vo, down)


(888) 597-WALL
www.wallindustries.com
JFCW48S12-1300
Trim
Trimup
Rup
Trimdown
Rdown
1%
12.120V 203.223 kΩ 11.880V 776.557 kΩ
2%
12.240V
99.057 kΩ
11.760V 380.723 kΩ
3%
12.360V
64.334 kΩ
11.640V 248.779 kΩ
4%
12.480V
46.973 kΩ
11.520V 182.807 kΩ
5%
12.600V
36.557 kΩ
11.400V 143.223 kΩ
6%
12.720V
29.612 kΩ
11.280V 116.834 kΩ
7%
12.840V
24.652 kΩ
11.160V 97.985 kΩ
8%
12.960V
20.932 kΩ
11.040V 83.848 kΩ
9%
13.080V
18.038 kΩ
10.920V 72.853 kΩ
10%
13.200V
15.723 kΩ
10.800V 64.057 kΩ
Page 5 of 14
TECHNICAL DATASHEET
Rev. B
JFCW48S12-1300
Remote ON/OFF Control
The remote ON/OFF pin allows the user to turn the DC/DC power module on and off from a remote switch device. The
ON/OFF input can be switched by a number of switching devices. Figure 5 gives several examples of acceptable
configurations. The remote ON/OFF switch is activated by the voltage difference between the ON/OFF pin and the –Vin pin
(with –Vin as the reference voltage). The user-supplied switch must be capable of sinking up to 1mA of current at low-level
logic voltage. The leakage current of the user-supplied switch must be 50μA or less at 15Vdc.
Remote ON/OFF Implementation
Figure 5
Isolated-Closure Remote ON/OFF
Level Control Using TTL Output
Level Control Using Line Voltage
There are two remote control options available: Positive logic and Negative logic
a. The positive logic structure turned the DC/DC module ON when the ON/OFF pin is at high-level logic and turned
the DC/DC module OFF when the ON/OFF pin is at low-level logic.
Figure 6
When JFCW module is turned OFF at Low-level logic
When JFCW module is turned ON at High-level logic
b. The negative logic structure turned the DC/DC module ON when the ON/OFF pin is at low-level logic and turned
the DC/DC module OFF when the ON/OFF pin is at high-level logic.
Figure 7
When JFCW module is turned ON at Low-level logic
(888) 597-WALL
When JFCW module is turned OFF at High-level logic
www.wallindustries.com
Page 6 of 14
TECHNICAL DATASHEET
JFCW48S12-1300
Rev. B
JFCW48S12-1300 Graphs. All test conditions are at 25°C
Graph 2: Efficiency vs. Input Voltage (Full Load)
Efficiency (%)
Efficiency (%)
Graph 1: Efficiency vs. Output Current
Input Voltage (V)
% Of Full Load
Graph 4: Output Power vs. Ambient Temperature with
Heatsink & Airflow (Nominal Vin)
Output Power (%)
Output Power (%)
Graph 3: Output Power vs. Ambient Temperature & Airflow
(Nominal Vin)
Ambient Temperature, Ta (°C)
Ambient Temperature, Ta (°C)
Graph 6: Typical Output Ripple and Noise
(Nominal Vin and Full Load)
Power Dissipation (W)
Graph 5: Power Dissipation Vs. Output Current
% Of Full Load
(888) 597-WALL
www.wallindustries.com
Page 7 of 14
TECHNICAL DATASHEET
JFCW48S12-1300
Rev. B
JFCW48S12-1300 Graphs (Continued). All test conditions are at 25°C
Graph 7: Typical Input Start-Up and Output Rise Characteristic
(Nominal Vin and Full Load)
Graph 9: Transient Response to Dynamic Load Change from
100% to 75% to 100% of Full Load at Nominal Vin
Graph 8: Using ON/OFF Voltage Start-Up and Vo Rise
Characteristic (Nominal Vin and Full Load)
Graph 10: Conducted Emission of EN55022 Class A
(Nominal Vin and Full Load)
Frequency (MHz)
Graph 11: Conducted Emission of EN55022 Class B
(Nominal Vin and Full Load)
Frequency (MHz)
(888) 597-WALL
www.wallindustries.com
Page 8 of 14
TECHNICAL DATASHEET
JFCW48S12-1300
Rev. B
TEST SETUP:
The JFCW48S12-1300 specifications are tested with the following configurations:
Input Reflected-Ripple Current Measurement Test Setup
CURRENT PROBE MEASURE POINT
Figure 8
+Vin
L
+
BATTERY
+
C2
C1
-Vin
Component
L
C1
C2
Value
12μH
10μF
10μF
Voltage
---100V
100V
Reference
---Aluminum Electrolytic Capacitor
Aluminum Electrolytic Capacitor
Peak-to-Peak Output Ripple & Noise Measurement Setup
Figure 10
Figure 9
Output Voltage and Efficiency Measurement Setup
Figure 11
 Vout  Iout 
Efficiency  
  100%
 Vin  Iin 
NOTE: All measurements are taken at the module terminals
(888) 597-WALL
www.wallindustries.com
Page 9 of 14
TECHNICAL DATASHEET
JFCW48S12-1300
Rev. B
EMC Considerations
Suggested Schematic for EN55022 Conducted Emission Class A Limits
C3
Figure 12
+INPUT
+Vin
C1
+Vout
C2
-INPUT
LOAD
-Vin
-Vout
D/D Converter
C4
Recommended Layout with Input Filter
Figure 13
The following components are needed to meet conducted emissions EN55022 Class A
JFCW24Sxx-xxxx
Component
C1
C2
C3, C4
Value
6.8μF
6.8μF
470pF
Voltage
50V
50V
2KV
Reference
1812 MLCC
1812 MLCC
1808 MLCC
JFCW48Sxx-xxxx
Component
C1
C2
C3, C4
(888) 597-WALL
Value
2.2μF
2.2μF
470pF
Voltage
100V
100V
2KV
www.wallindustries.com
Reference
1812 MLCC
1812 MLCC
1808 MLCC
Page 10 of 14
TECHNICAL DATASHEET
Rev. B
JFCW48S12-1300
EMC Considerations (Continued)
Suggested Schematic for EN55022 Conducted Emission Class B limits
Figure 14
Recommended Layout with Input Filter
Figure 15
The following components are needed to meet conducted emissions EN55022 Class B
Figure 16: Common Choke (L1)
JFCW24Sxx-xxxx
Component
C1, C3
C2
C4, C5
L1
Value
6.8μF
--470pF
325μH
Voltage
50V
--2KV
---
Reference
1812 MLCC
--1808 MLCC
Common Choke
JFCW48Sxx-xxxx
Component
C1, C3
C2
C4, C5
L1
Value
2.2μF
2.2μF
1000pF
325μH
Voltage
100V
100V
2KV
---
Reference
1812 MLCC
1812 MLCC
1808 MLCC
Common Choke
Dimensions: mm
L: 325μH±35% / DCR: 35Ω, max
Height: 8.8mm, max.
Test conditions: 100KHz / 100mV
Recommended through hole: Φ0.8mm
(888) 597-WALL
www.wallindustries.com
Page 11 of 14
TECHNICAL DATASHEET
JFCW48S12-1300
Rev. B
Recommended Pad Layout
Figure 17
1. All dimensions in inches [mm]
2. Tolerance: x.xxx±0.010 inches
xx.xx±0.25 mm
Pad Size (Lead Free Recommended)
Pin Through Hole: Ø 0.047 in (1.2mm)
Top View Pad: Ø 0.079 in (2.0mm)
Bottom View Pad: Ø 0.118 in (3.0mm)
Soldering and Reflow Considerations:
Lead Free Wave Solder Profile for JFCW-Single Output Models
Figure 18
TEMPERATURE (°C)
Zone
Preheat Zone
Actual Heating
Reference Parameter
Rise temp. speed: 3°C/sec max.
Preheat temp: 100~130°C
Peak temp: 250~260°C
Peak time (T1+T2 time): 4~6 sec
Reference Solder: Sn-Ag-Cu; Sn-Cu
Hand Welding: Soldering Iron: Power 90W
Welding Time: 2~4 sec
Temp: 380~400°C
TIME (SEC)
Packaging Information:
Figure 19
300
Unit: mm
26.5
19
10 PCS per Tube
6
(888) 597-WALL
www.wallindustries.com
Page 12 of 14
TECHNICAL DATASHEET
JFCW48S12-1300
Rev. B
Safety and Installation Instructions:
Fusing Consideration
Caution: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of sophisticated power architecture. For maximum flexibility internal fusing is not
included; however, to achieve maximum safety and system protection always use an input line fuse. The safety
agencies require a normal-blow fuse with maximum rating of 3A for JFCW24Sxx-xxx modules and 1.5A for
JFCW48Sxx-xxx. Based on the information provided in this data sheet on inrush energy and maximum DC input
current; the same type of fuse with lower rating can be used. Refer to the fuse manufacturer’s data for further
information.
MTBF and Reliability
The MTBF of the JFCW single output series of DC/DC converters has been calculated using Bellcore
TR-NWT-000332 Case I: 50% stress, Operating Temperature at 40°C (Ground fixed and controlled environment).
The resulting figure for MTBF is 1,330,000 hours.
MIL-HDBK 217F NOTICE2 FULL LOAD, Operating Temperature at 25°C. The resulting figure for MTBF is
563,000 hours.
Ordering Information:
Part Number Example:
JFCW
48
S
12
- 1300
R
Series
Designation
Nominal
Input Voltage
Single Output
Nominal
Output Voltage
Output Current
Suffix
R
No Suffix
D
G
RF
F
(888) 597-WALL
www.wallindustries.com
Option
Negative Remote ON/OFF
Positive Remote ON/OFF
Without ON/OFF pin
Without ON/OFF & TRIM pin
Negative Remote ON/OFF without TRIM pin
Positive Remote ON/OFF without TRIM pin
Page 13 of 14
TECHNICAL DATASHEET
Rev. B
JFCW48S12-1300
Company Information:
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and
development engineers will provide a solution that exceeds your performance requirements on time and on budget.
Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well
documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for
working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements.
We will continue to provide ongoing support for your project above and beyond the design and production phases.
Give us a call today to discuss your future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
(888) 597-WALL
(603)778-2300
(888)587-9255
(603)778-9797
[email protected]
www.wallindustries.com
5 Watson Brook Rd.
Exeter, NH 03833
www.wallindustries.com