Product family datasheet QUICKTRONIC PROFESSIONAL M ECG for CFL Areas of application _ Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100 _ Public buildings _ Sports halls and factories _ Suitable for luminaires of protection class I __ Product benefits _ Long lamp life _ No adverse effect from frequent on/off switching _ Automatic restart after lamp replacement _ Perfect lamp start for applications with motion sensors _ Separate installations thanks to optional cable clamp for K2 and K3 casings _ VDE/VDE EMC certified system Product features _ Supply voltage: 220…240 V _ Line voltage: 198…264 V _ Line frequency: 0 Hz | 50 Hz | 60 Hz _ Lamp start with optimum filament preheating _ Energy Efficiency Index EEI: A2 _ Automatic shutdown of defective lamps and at end of life (EoL T.2) _ Lamp operation: to EN 60929 _ Safety: to EN 61347-2-3 June 20, 2016, 16:48:09 QUICKTRONIC PROFESSIONAL M © 2016, OSRAM GmbH. All rights reserved. Page 1 of 8 Product family datasheet Technical data Electrical data Product description Input voltage AC Nominal voltage Mains frequency Input voltage DC QTP-D/E 2X10…13 1) 198…264 V 220…240 V 50…60 Hz 176…276 V 2) QTP-T/E 1X18,2X18 198…264 V 220…240 V 50…60 Hz 176…264 V QTP-T/E 1X26…42,2X26 1) 198…264 V 220…240 V 50…60 Hz 176…276 V 198…264 V 220…240 V 50…60 Hz 176…276 V 2) 198…264 V 220…240 V 50…60 Hz 176…276 V 2) QTP-D/E 1X10…13 QTP-T/E 2X18 1) 1) 1) Optional cable clamp, see chapter ECG mountings - cable clamp 2) Minimum voltage for lamp ignition: 198 V Light technical data Product description Starting time QTP-D/E 2X10…13 1) 1.0 s QTP-T/E 1X18,2X18 QTP-T/E 1X26…42,2X26 1.0 s 1) QTP-D/E 1X10…13 1) QTP-T/E 2X18 1.0 s 1.0 s 1) 1.0 s __ 1) Optional cable clamp, see chapter ECG mountings - cable clamp Dimensions & weight Product description Length Width Height Mounting hole spacing, length Product weight Cable crosssection, input side QTP-D/E 2X10…13 1) 123.0 mm 79.0 mm 33.0 mm 111.0 mm 190.00 g 0.5…1.5 mm² QTP-T/E 1X18,2X18 103.0 mm 67.0 mm 31.0 mm 94.0 mm 149.00 g 0.5…1.5 mm² 103.0 mm 67.0 mm 31.0 mm 94.0 mm 148.50 g 0.5…1.5 mm² 93.0 mm 58.0 mm 29.0 mm 84.0 mm 100.00 g 0.5…1.5 mm² 123.0 mm 79.0 mm 33.0 mm 129.5 mm 190.00 g 0.5…1.5 mm² QTP-T/E 1X26…42,2X26 1) QTP-D/E 1X10…13 1) QTP-T/E 2X18 1) Product description Cable crosssection, output side QTP-D/E 2X10…13 1) 0.5…1.5 mm² QTP-T/E 1X18,2X18 QTP-T/E 1X26…42,2X26 QTP-D/E 1X10…13 0.5…1.5 mm² 1) 1) QTP-T/E 2X18 1) 0.5…1.5 mm² 0.5…1.5 mm² 0.5…1.5 mm² 1) Optional cable clamp, see chapter ECG mountings - cable clamp June 20, 2016, 16:48:09 QUICKTRONIC PROFESSIONAL M © 2016, OSRAM GmbH. All rights reserved. Page 2 of 8 Product family datasheet Product line drawing QTP-D/E 2X10…13 QTP-T/E 1X18,2X18, QTP-T/E 1X26…42,2X26, QTP-T/E 2X18 __ QTP-D/E 1X10…13 June 20, 2016, 16:48:09 QUICKTRONIC PROFESSIONAL M © 2016, OSRAM GmbH. All rights reserved. Page 3 of 8 Product family datasheet Temperatures & operating conditions Product description Ambient temperature range QTP-D/E 2X10…13 1) -20…+50 °C QTP-T/E 1X18,2X18 -20…+50 °C QTP-T/E 1X26…42,2X26 1) -20…+50 °C QTP-D/E 1X10…13 1) -20…+50 °C QTP-T/E 2X18 1) -20…+50 °C 1) Optional cable clamp, see chapter ECG mountings - cable clamp Lifespan Product description QTP-D/E 2X10…13 ECG lifetime 1) 50000 h 2) QTP-T/E 1X18,2X18 50000 h 2) QTP-T/E 1X26…42,2X26 1) 50000 h 2) QTP-D/E 1X10…13 1) 50000 h 2) QTP-T/E 2X18 1) 50000 h 2) 1) Optional cable clamp, see chapter ECG mountings - cable clamp 2) At T case = 75°C at T point / 10% failure rate c __ Expected Lifetime Product name QTP-T/E 1X18,2X18 Lamp group DULUX T/E 18 W ECG ambient temperature [ta] 40 50 60 Temperature at tc-point [°C] 55 65 70 100000 100000 60000 ECG ambient temperature [ta] 40 50 60 Temperature at tc-point [°C] 55 65 70 100000 100000 60000 ECG ambient temperature [ta] 40 50 60 Temperature at tc-point [°C] 55 65 70 100000 100000 60000 ECG ambient temperature [ta] 40 50 60 Temperature at tc-point [°C] 55 65 70 100000 100000 60000 Lifetime [h] Product name Lamp group DULUX D/E 26 W Lifetime [h] QTP-T/E 1X26…42,2X26 DULUX T/E 42 W Lifetime [h] DULUX T/E 26 W Lifetime [h] June 20, 2016, 16:48:09 QUICKTRONIC PROFESSIONAL M © 2016, OSRAM GmbH. All rights reserved. Page 4 of 8 Product family datasheet Capabilities Product description Suitable for fixtures with prot. class End of lamp life safety shutdown QTP-D/E 2X10…13 1) I / II EOL T.2 QTP-T/E 1X18,2X18 I / II EOL T.2 QTP-T/E 1X26…42,2X26 1) I / II EOL T.2 I / II EOL T.2 I / II EOL T.2 QTP-D/E 1X10…13 1) QTP-T/E 2X18 1) 1) Optional cable clamp, see chapter ECG mountings - cable clamp Certificates & standards Product description Approval marks – approval EEI – Energy Label Protection class QTP-D/E 2X10…13 1) VDE / VDE-EMC / ENEC 10 / GOST / RCM A2 III QTP-T/E 1X18,2X18 VDE / VDE-EMC / ENEC 10 / GOST / RCM A2 BAT III QTP-T/E 1X26…42,2X26 1) VDE / ENEC 10 / VDE-EMC / GOST / RCM A2 BAT III VDE / VDE-EMC / ENEC 10 / GOST / RCM A2 III VDE / VDE-EMC / ENEC 10 A2 III QTP-D/E 1X10…13 1) QTP-T/E 2X18 1) __ 1) Optional cable clamp, see chapter ECG mountings - cable clamp June 20, 2016, 16:48:09 QUICKTRONIC PROFESSIONAL M © 2016, OSRAM GmbH. All rights reserved. Page 5 of 8 Product family datasheet Wiring Diagram QTP-D/E 2X10…13, QTP-T/E 2X18 QTP-T/E 1X18,2X18, QTP-T/E 1X26…42,2X26 QTP-T/E 1X18,2X18, QTP-T/E 1X26…42,2X26 QTP-D/E 1X10…13 __ Application advice For more detailed application information and graphics please see product datasheet. June 20, 2016, 16:48:09 QUICKTRONIC PROFESSIONAL M © 2016, OSRAM GmbH. All rights reserved. Page 6 of 8 Product family datasheet Sales and Technical Support Sales and Technical Support www.osram.com Country specific information Product description Product code METEL code SEG number STK number UK Org QTP-D/E 2X10…13 4008321181596 OSRQTPDE2X1013 7980277 4031139 - QTP-T/E 1X18,2X18 4008321537065 - 7980338 4030041 - QTP-T/E 1X26…42,2X26 4008321537089 - 7980339 4030031 - QTP-D/E 1X10…13 4008321181572 OSRQTPDE1X1013 7980275 4031141 - QTP-T/E 2X18 4008321181619 OSRQTPTE2X18 - - - Download Data File Certificates ENEC-Marks approval __ Certificates EMC-Marks approval QTP-M Certificates INOTEC Certificates Manufacturer´s declaration LampECG combinations: Frequent switching Certificates VDE-EMC-Certificate QTP DL_TE Declarations of conformity CE conformity Operating instructions EAC QTP-DE + QTP-TE CAD data 3-dim CAD QTP-DE CAD data 3-dim CAD QTP-DE CAD data PDF 123x79x33 9900041 CAD data PDF CAD QTP-DE Product Datasheet ECG lifetime - QUICKTRONIC non DIM CAD data 3-dim 93x58x29 9900039 June 20, 2016, 16:48:09 QUICKTRONIC PROFESSIONAL M © 2016, OSRAM GmbH. All rights reserved. Page 7 of 8 Product family datasheet CAD data 3-dim 93x58x29 9900039 CAD data 3-dim 93x58x29 9900039 CAD data PDF 93x58x29 9900039 Logistical Data __ Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height) Volume Gross weight 4008321181596 QTP-D/E 2X10…13 Shipping carton box 20 428 mm x 78 mm x 257 mm 8.58 dm³ 4017.67 g 4008321537065 QTP-T/E 1X18,2X18 Shipping carton box 20 360 mm x 101 mm x 230 mm 8.36 dm³ 3266.00 g 4008321537089 QTP-T/E 1X26…42,2X26 Shipping carton box 20 355 mm x 96 mm x 220 mm 7.50 dm³ 3192.00 g 4008321181572 QTP-D/E 1X10…13 Shipping carton box 20 315 mm x 66 mm x 196 mm 4.07 dm³ 2127.00 g 4008321181619 QTP-T/E 2X18 Shipping carton box 20 428 mm x 78 mm x 257 mm 8.58 dm³ 4072.25 g The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit. Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. June 20, 2016, 16:48:09 QUICKTRONIC PROFESSIONAL M © 2016, OSRAM GmbH. All rights reserved. Page 8 of 8