ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Pico Product #: 473xxxHF Series Issue Date: May 23, 2011 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the Pico RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Pb (lead) contained in the high temperature melting solder > 85% and is categorized as exempt under section 7a of the RoHS Annex. Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 7 8 Raw Material Part Number 909-371 082xxx-001 692320 910-271 648102 648106-001 648112-001 087340 Raw Material Description Body Element - 99% Cu Sn Plated Solder Caps & Lead Assay Yarn Yarn Yarn Epoxy Powder (HF Gold) 2 Page(s) 3-8 9-15 16-21 22-26 27-33 34-39 40-45 46-52 Test Report Applicant: Number : TWNC00176941 Littelfuse, Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Oct 08, 2010 Sample Description: One (1) group of submitted samples said to be : Part Description : Body Part Number : 909-371 Date Sample Received : Oct 04, 2010 Date Test Started : Oct 05, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176941 Test Conducted (Ⅰ) Test Result Summary : Testing Item Result (ppm) Gray Material Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND 94 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Oct 04, 2010 : Oct 05, 2010 To Oct 07, 2010 Page 2 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176941 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176941 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176941 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill the calorimetric bomb with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 5 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176941 Test Conducted Photo Page 6 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Validi ForQu Please Test Report No.i CE/2010/C0089D4e | 2O1U12108 Page: I of 7 POLYFILAG OBERALLMENDSTRASSE 2OA,CH{3OOZUG/ SWITZERLAND Thefollowingsampte(s)tuas/weresubmitted and identified by/on SampleDe6cription Buye/OrderNo. SampleReceiving Date TestingPeriod Cugg.gMSn 104987 2010t12t01 2010t12t0110 201u 12t08 TestReeult(s) Pleasereferto nextpage(s). l] behalf of the cliont as: g|||d6.||d 66{cd lrtadory cmFnyl trii, { ;,l|t, - f*d aG)r8dd rh s 16! mpod €md ! . 1 , + 1 j , ' 1 t t i : Ji . l . r i i l . r i r r t : = t j : . , t . r . . . . , r { } ! . ftseumed3$cdbylhecomFnysuqadbi9G6a6|cmdfuBdSa t* abrmt tomd do.lm6tu s6i b€ € g *"-,*rn, lb'.qhbds|€*trssdlb'6 ! iddrarzoE.ri*,.o!d!riiwld/r,t6i Ilr: rcnoi, so*r ttt ttltl TestReport No.I CE2010IC0089 Date: 2010/1208 P a g e t 2 o l T POLYFILAG OBEMLLMENOSTRASSE 2OA,CH63OOZUG/ SWITZERLAND ll!][ttt Test Ro€ult{sl PARTNAMENo.1 SILVERCOLOREDMETALWIRE Testltem (s): Unit Cadmium(Q) Method MDL mg/Kg Withreference to IEC62321:2008anC 2 mgag Withreference to tEcG232iJZdd8 andperformed byICP-AES. mg/Kg Withreference to lECGI321l2666?iI perfomed byICP-AES. 2 performed by ICP-AES. Lead (Pb) Mercury(Hg) Hexavaler( Chromium -r(Vt)If Spottest / boilingwaterextraction Halogen Halogen-Fluodne (F) (CASNo.:014762-94-8) Halogen-Chlorine (Cl) (CASNo.:022537-15-1) Halogen-Bromine (Br) (C.AS No.| 010097-32-2) Hexabromobiphenyl Heptabromobiphenyl Oclabromobiphenyl Nonabromobiphenyl Decabromobiphenyl n.o, Withreference to IEC62321:2008€nd 0.02mg/kg Negative performedby Spottest/ boilingwater with50cm, extraclionMethod.(SeeNote6) surtace Withreferenceto BS EN 1458212007. mg/Kg Analysiswasperformedby lC. Halogenlodine (l) (CASNo.i01436244-8) Sumof PBBS Monobromobiphenyl Dibromobiphenyl Tribrcmobiphenyl Tetrabromobiphenyl Pentabromobiphenyl Result No.l n.o. 50 n.d. 50 n.d. 50 n.d. 50 n.d. n.o. mg/Kg n.d. n.d. n.d. n.d. n.d, n.d. n.d. n.d. With referenceto IEC 62321:2008€nd perfomed by GC/MS. n.o. 5 'n1h!Bll6p.nGi€l0ilybhsgmp3G)bddThsb3i@d€nidbtrFd cdFry rr'rrEl. i ]i .r 1r r?rFlri dllli ilr, r jr l.ii,rl-\-+:i nj6d@md€]fudbylbconpanysUqedbbcae6!coidlo^5o's t .f r-lrtz]]!. !,tr : rr Ii.]ri (,e6r]D n.o. tt l TestReport No.: CE/201CyC0089 D?f.e :2O1Oh2tO8P e g e : 3 o f 7 POLYFILAG OBEMLLMENDSTRASSE 2OA,CH63OO ZUG/ SWITZERLANO Test ltem (s): Sumof PBDES It4onobomodiphenyl ether Dbromodiphenyt ether f ribromodiphenyl ether Ietrabromodiphenyi ettter Pentabromodiphenyl ether Unit mg/kg Hexablomodiphenyt ether rtr] lr||tflrltl! Mothod MDL Withreference to tEC62321i2OO8 end performedby GC/[/|S. Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabbmodiphenyl ether 5 5 5 5 5 5 Result No.1 n.d. n.d. n.d. n.d. n.o. n.d. n-d. n.d. n.d. n.d. n.d. Note: 1. mg/kg= ppm i 0.1wt%= lOOOppm 2. n.d.= Not Detecled 3. MDL= MothodDet€ctionLimit 4-"-"=NotRegulated 5. " = Qualitative analysis (NoUnit) 6. Spot-test: Negative= Abs€nceof cr(vr) coating/ surfac€rayer;po.irive = presenceof cr(vr) coating/ surfacerayer; (Thet€stedsampleshouldbefurtherverifiedby boaling-water-extraction methodif thespottestresultcannot be confi|med.) BoiIing-eEter-extraction: Negative= Absenceof Cr(Vl)coating/ surfacetayer; positive= Presenceof Cr(Vl)coating/ surfacelayea; Thedetected concent€tion in boiling-water-extraction solutionis equalor greaterthan0.02mg/kgwith50cm, samDlegurfacearea. cmFiy ror ebdmd lLI1l,: rtnr ..I!!li 1i.'-.:11,l.tlltr ^y3u!,adloisG4e6|cddi66olS ionnd @msnb su! siirri .i : . -i :i: j. : rlanrjt. f u f ' g h a a d @ E d l o n s u 6 l f u l € m o l b e b p o d u d * c a p l n f u l * i h d rHr li i:: 'rri:.4 r +$6rcrrne MembsorhescsGolp665sAl Test Report No.: CEI2010/C0089Date| 2O1Ot12tO8P age:4 ol7 POLYFILAG OBEMLLITIENDSTMSSE2OA,CH-6300ZUG / SWTTZERLAND lllutI|lll|l||tlll 1) Th€s.esafiples were dissoh/€dtotalv by pre-conditioningnEthod according to below flow chart I ur tesl rEthod ercluded) 2) Narneof tho personwho rEde llEasurenEr t Climbgreat yang 3) llarE ofthe personin cha.geof nEasuremeit:TroyChang Cutting/ Preparatbn Aciddigestion by suitaueacid dependedon differentsanDle nEterial(as belowtabte) Microwavedigestionwith HI.IOJHCUHF Addappropdateanbuntof digestionreagent lleat to appropriate tefiperatureto extrerct 'l) AlkaliFusion 2) rclto dissotue Add diphenyl-carbezide for colordevelopnEnt Safipb Matedal DigestionAcid Steel,copper, aluninum,solder Aqua regia,HNO3,HCl,HF,H2O, Gbss HNO3/HF Gold,platinunpalladium, ceraric Aquaregia Situer HNO3 Plastic ft so4, ft or, HNo3,Hcl Others Anyacidto totaldigestion cmp.iyi'j|,j.':i;',tti1:.:}lJ::.;iljiii1i..ftl1.}i{.]] n3dms'€csuadbyihecomp'iy5u$d|oGc*6|cdrddoBols rq 0i.d,6c romd e{ims6 su!6d b r6ms ad codroB rd Erdm. Ibr'qhtsaM@|Fd65tldlful€ M'on6 rary rEcm@rsso6i€ 0o@m6n5d *w sls 6d1.n: 6i.amd rEasure the ab60rbance at 540 nmby W-VIS hm Ard o; s dtui ro rhe ,mMlo d ,ab,q msd dk ^d dssEb Fi€s b a r& Test Report No.: CE/2010/C0089Oate:2OiOhZO8 P a g e : 5 o f 7 POLYFILAG OBEMLLMENDSTRASSE2OA,CH63OOZUG / SWITZERTAND [ [llt]|||tt Analtticalflow chartof halogencontgnt 1) ll€rle of the p€rsonwho rnade nEasurenEnt: Rita Chen 2) t,lanF ofthe personin chargeof ftEasurenEnt:TroyChang Saftplepretreatment / Separation Weighting andputtingsanplein cell OrygenBombCoflbustion /AbsoDtion Dilutionto fixedvoluftE Analysiswaspertorr€d b\, lC ' . + : n6ddmdA3Gbyhecorr ior€edrcnc foma' doondG. subl n Gfio.tsh6 comFiy 3 r id]^gs ar bs rharl'drbadd 0d ms undd66 tra sponebrt 3ro b cttrr ands s tu6 .ji .r ftr rlif . ti,eozrrer&r+86 arrszT !__{,<,, TestReport No.: CE2010/C0089 Datet2010/1|2108page:6 of z POLYFIL AG OBERALLMENDSTMSSE 2OA,CH$3OO ZUG/ SWITZERLAND trl| [tt||||!tllt PBB/PBDEanatyticatFLOWCHART 1) tbnE of thepe6on who fibcle rEasureriEnl. Rormn Wono 2) Mrne of the personin chargeof i€asurenent: troy Cnanpf Firsttestingprocess-----' Odionalscreenprocess--.Confinmtion process - .> Screenanalysis Sanple extractiod I Soxhtet I=----r----- nEthod I I ConcentratdDilute Extractedsolulion t Filter -I - - - - - - - - - . - - - - - I Analysis by GC/MS - il i i : r t r 1 ; , : , r r t : , : . i i i . l . r i - r t. : : r ; I . . . n1:. ny&qed|oiscme6|cddioBolsg 'd.e@,domd @metu sdi , eoamen{hm a,en,o; s d€". ; h"t.6,rerons f 'ny rh. cnpanys $ s,* d "b a TestReport No.: CE2010/C0089 Dale| 2O1Ot1ZOaP a g e : 7 o f 7 POLYFILAG OBERALLMENDSTMSSE2OA,CHS3OOZUG / SWITZERLAND I|]t|:tt]t||lrl|t c0089 " Endof Report " c d n p ' ^ ri : r ' 1 r r l t . , t r r l i r r . r ' r ?.j, r 1 r l t e i . J . : t 1 l t i r . : r \ n r L ! 1 . , i , . rc ed,mr rdmai @i.d3 rl1r1.. slq s enotumemhh o n t a n dw l h i h 6 r m c d c . d s n r ndb..qducdoxc€p{iful*lbdl lPe.o{'rliwai/irLL:jrt]'ItrlB fr.d,o; E d,en Test Report No: 10222124(1) Date: 19-Jan-11 Page 1 of 6 Kester Components Pte Ltd 500 Chai Chee Lane, Singapore 469024 The following sample(s) was/were submitted and identified by/on behalf of the client as: Sample Description : RK-3-K71 (P/N: 692320 / Lot: 1004401007) Sample Receiving Date Testing Period : : 12-Jan-11 13-Jan-11 to 18-Jan-11 Test Requested : In accordance with the RoHS Directive 2002/95/EC, and its amendment directives. Test Result(s) : Please refer to next page(s). Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS Directive 2002/95/EC and its subsequent amendments. Signed for and on behalf of SGS Testing & Control Services Singapore Pte Ltd Y.C. Tham Laboratory Manager Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group Test Report No: 10222124(1) Date: 19-Jan-11 Page 2 of 6 Test Result(s): Sample Description : Test Item(s): RK-3-K71 (P/N: 692320 / Lot: 1004401007) Unit Method Results MDL RoHS Limit Cadmium(Cd) mg/kg With reference to IEC62321, Ed1:2008. Analysis was performed by ICP/AES n.d. 2 100 Lead (Pb) mg/kg With reference to IEC62321, Ed1:2008. Analysis was performed by ICP/AES 901893.9+ 2 1000 Mercury (Hg) mg/kg With reference to IEC62321, Ed1:2008. Analysis was performed by ICP/AES n.d. 2 1000 Negative 0.02 mg/kg with 50 cm2 surface area # n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. n.d. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 1000 1000 - Hexavalent Chromium (CrVI) (By spot test / boiling water extraction) Sum of PBBs Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Hexabromobiphenyl Pentabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sum of PBDEs Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether ## --- With reference to IEC62321, Ed1:2008 and performed by Spot test / boiling water extraction method. (see Note 9) mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg With reference to IEC62321, mg/kg Ed1:2008. Analysis was mg/kg performed by GC/MS mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group Test Report No: 10222124(1) Date: 19-Jan-11 Page 3 of 6 Note: (1) mg/kg = ppm ; 0.1wt% = 1000ppm (2) n.d.= Not Detected (3) MDL = Method Detection Limit (4) ## = The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled by the European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE will be included in the sum of PBDE after 01.07.2008. (5) “-“ = Not regulated (6) “---“: No unit (Qualitative Test) (7) * : Exceeds limit (8) # : Positive means the presence of CrVI on the tested areas. Negative means the absence of CrVI on the tested areas. (9) Spot-test: Negative = Absence of Cr(VI) coating / surface layer Positive = Presence of Cr(VI) coating / surface layer The tested sample should be further verified by boiling-water-extraction method if the spot test result cannot be confirmed. Boiling-water extraction: Negative = Absence of Cr(VI) coating / surface layer Positive = Presence of Cr(VI) coating / surface layer the detected concentration in boiling-water-extraction solution is equal or greater 2 than 0.02 mg/kg with 50 cm sample surface area. + Exemption: The received sample is exempted under directive 2002/95/EC Annex Article 7: lead in high melting temperature solder type solders (i.e. tin-lead solder alloys containing more than 85% of lead). Lab Analyst(s): Jay, Jojo and Eileen Remarks: Sample received was totally dissolved by preconditioning method. Sample photo: Sample Description : RK-3-K71 (P/N: 692320 / Lot: 1004401007) SGS authenticate the photo on original report only Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group Test Report No: 10222124(1) Date: 19-Jan-11 Page 4 of 6 Process Flow of IEC 62321 (Pb, Cd, Hg & Cr 6+) Cutting / Preparation Cr (Vl) Sample Measurement Hg Pb,Cd Acid digestion by suitable acid depended on different sample material Microwave digestion with HNO3/HCl/HF Add appropriate amount of digestion reagent Heat to appropriate temperature to extract Filtration Solution Residue Cool, filter digestate through filter 1)Alkali Fusion 2)HCl to dissolve Add diphenyl-carbazide for color development ICP-AES Measure the absorbance at 540 nm by UV-VIS Remarks: Sample received was totally dissolved by preconditioning method. (CrVl method excluded) Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group Test Report No: 10222124(1) Date: 19-Jan-11 Page 5 of 6 Process Flow of Cr(Vl) by Boiling Water Extraction (IEC62321) Add appropriate amount of DI water Heat to appropriate temperature to extract Cool, filter digestate through filter Add diphenyl-carbazide for color development A red color indicates the presence of CrVl Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group Test Report No: 10222124(1) Date: 19-Jan-11 Page 6 of 6 Process Flow of PBBs and PBDEs by GC/MS (IEC 62321) First Testing Process → Optional screen process …… Confirmation process ...→ Cutting/Preparation Sample Pre-treatment Screening Analysis Solvent Extraction Concentrate/Dilute extracted solution Filter High Mass Range GC/MS Data ***End of Report*** Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group Test Report Applicant: Number : TWNC00182566 Littelfuse, Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 22, 2010 Sample Description: One (1) group of submitted samples said to be : Part Description : Caps/ Lead Assay (metal) Part Number : 910-271 Date Sample Received : Nov 17, 2010 Date Test Started : NOV 17, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182566 Test Conducted Result (ppm) (1) (2) Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) ND ND ND ND ND ND Negative Negative (< 0.02)(#) (< 0.02)(#) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of testing. # = Due to the insufficient sample area, reduced total sample surface of 10 cm2 was used and the dilution factor was adjusted accordingly. Tested Components (1) Coppery Substrate (2) Silvery Plating Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Nov 17, 2010 : Nov 17, 2010 To Nov 22, 2010 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182566 Test Conducted (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182566 Test Conducted (IV) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End Of Report Page 4 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182566 Test Conducted Photo Page 5 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00176948 Littelfuse, Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Oct 07, 2010 Sample Description: One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648102 Date Sample Received : Oct 04, 2010 Date Test Started : Oct 05, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176948 Test Conducted (Ⅰ) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result (ppm) White Fabric ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Page 2 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176948 Test Conducted (Ⅰ) Test Result Summary : Testing Item Result (ppm) White Fabric Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Oct 04, 2010 : Oct 05, 2010 To Oct 07, 2010 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 3 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176948 Test Conducted (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176948 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Cr Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Weigh sample and add organic solvent By spot test Negative Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176948 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill the calorimetric bomb with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 6 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00176948 Test Conducted Photo Page 7 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00183561 Littelfuse, Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 30, 2010 Sample Description: One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648106-001 Date Sample Received : Nov 25, 2010 Date Test Started : Nov 25, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183561 Test Conducted (Ⅰ) Test Result Summary : Testing Item Result (ppm) White Yarn Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Nov 25, 2010 : Nov 25, 2010 To Nov 29, 2010 Page 2 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183561 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183561 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183561 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 5 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183561 Test Conducted Photo Page 6 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00183563 Littelfuse, Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 30, 2010 Sample Description: One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648112-001 Date Sample Received : Nov 25, 2010 Date Test Started : Nov 25, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183563 Test Conducted (Ⅰ) Test Result Summary : Testing Item Result (ppm) White Yarn Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Nov 25, 2010 : Nov 25, 2010 To Nov 29, 2010 Page 2 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183563 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183563 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183563 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 5 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00183563 Test Conducted Photo Page 6 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00182411 Littelfuse, Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 22, 2010 Sample Description: One (1) group of submitted samples said to be : Part Description : Epoxy Powder (Gold-HF) Part Number : 087340 Date Sample Received : Nov 16, 2010 Date Test Started : Nov 17, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182411 Test Conducted (Ⅰ) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result (ppm) Yellow Powder ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Page 2 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182411 Test Conducted (Ⅰ) Test Result Summary : Testing Item Result (ppm) Yellow Powder Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND 651 ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Nov 16, 2010 : Nov 17, 2010 To Nov 19, 2010 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 3 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182411 Test Conducted (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182411 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182411 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill the calorimetric bomb with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 6 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00182411 Test Conducted Photo Page 7 Of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401