EN

Inductive sensors
IWRR 18I97T4/S14
Inductive distance measuring
sensors
dimension drawing
60
43
M18 x 1
SW 24
M12 x 1
general data
photo
mounting type
quasi-flush
special type
Outdoor design
Washdown design
0 ... 7 mm
measuring distance Sd
resolution
repeat accuracy
< 0,005 mm (stat.)
< 0,01 mm (dynam.)
< 0,015 mm
linearity error
± 350 µm
temperature drift
± 10 % (Full Scale)
approvals/certificates
Ecolab
electrical data
response time (factory characteristic)
< 2 ms
voltage supply range +Vs
15 ... 30 VDC
current consumption max. (no load)
40 mA
output circuit
current output
output signal
4 ... 20 mA
load resistance +Vs min.
< 330 Ohm
load resistance +Vs max.
< 1000 Ohm
short circuit protection
yes
reverse polarity protection
yes
connection diagram
IWRR
~
~
~
BN (1)
+VS
WH/BK (2/4)
BU(3)
output
Z
0V
mechanical data
cylindrical threaded
material (sensing face)
LCP
housing material
stainless steel 1.4404 (V4A)
dimension
18 mm
housing length
60 mm
connection types
connector M12
installation drawing
8
4 ±0,2
type
ambient conditions
operating temperature
-40 ... +70 °C
cleaning temperature
70 ... +85 °C (30 min/day)
protection class
IP 68/69K & proTect+
vibration resistance
EN 61373: 2010 (category 3), 5h per axis
(14.4 gRMS, 10-500 Hz, EN 60068-2-64)
EN 61373: 2010 (category 3), 10 bumps per
axis (100 g, 6 ms, EN 60068-2-27)
shock resistance
IWRR 18I97T4/S14
www.baumer.com
Sensor FDA compliant and Ecolab
approved
24/5/2016