30-08-2005 12:35:44 Project: IR REFLOW TESTING 250 T(°C) Company: SEMTECH CORP Operator: QA/REL TECH Process: IR REFLOW Product: TO-263 PACKAGE Created: 21-11-02 11:14:59 Updated: 01-06-05 16:53:52 Oven: SMRO-0252 200 150 Comment: TEMP RANGE = 225°C +0 / -5 °C 100 Ventilator: OFF Speed: 17 (cm/min) Zones Upper Lower #1 370 370 #2 215 215 #3 280 280 #4 335 335 50 t(s) 50 Name - Probe Nr. 3147-1-3 Curve1 Max. Temp. reached, t=[0s-497s] Temp. Reached at 224 351.47 100 Time above 150°C Reached at - Duration 149.52 147 18 -5.00 250.20 389 200 Time above 183°C Reached at - Duration Max. Slope, T=[150°C-183°C] Slope - Reached at - Duration Slope - Reached at - Duration 0.33 150 1 267.47 250 300 Time above 225°C Reached at - Duration 121.52 -- 302 3 -5.00 -- 389 400 450 500 Max. Slope, T<150°C Slope - Reached at - Duration Slope - Reached at - Duration 3.00 Max. Slope, T=[183°C-225°C] Slope - Reached at - Duration Slope - Reached at - Duration 1.00 350 1 38 1 -7.00 403 1 Max. Slope, T>225°C Slope - Reached at - Duration Slope - Reached at - Duration -- -- -- -- -- --