Photoelectric sensors OM70-X0500.HI0660.VI OM70-11112069 Distance sensors dimension drawing 26 4,3 5 14 7 9 64 50 74 85 9 LED 4,5 2 19 M12 x 1 55 * emitter axis general data photo version MESAX 70 multi-spot measuring distance Sd 100 ... 500 mm measuring range (width) 13 ... 66 mm adjustment Touch Display, RS485 power on indication LED green resolution 4 ... 25 µm 1) 2) 4) 5) linearity error ± 100 µm 1) 2) 4) 6) repeat accuracy 4 ... 20 µm 1) 2) 4) 5) light source pulsed red laser diode wave length 660 nm laser class 2 beam type multi-spot temperature drift ± 0,04 % Sde/K 1) 2) 4) connection diagram electrical data BN (2) response time / release time 1,3 ms 2) 3) measuring frequency 1540 Hz 2) 3) voltage supply range +Vs 15 ... 28 VDC current consumption max. (no load) 120 mA output circuit analog and RS 485 baud rate 115200, adjustable output signal 4 ... 20 mA / 0 ... 10 VDC output current < 100 mA short circuit protection yes reverse polarity protection yes, Vs to GND Z YE (4) RS 485 GY(5) WH (1) pushPK (6) pull RD (8) BU (7) Z Z +Vs analog out alarm Rx/TxRx/Tx+ sync in 0V laser warning LASER RADIATION DO NOT STARE INTO BEAM Wavelength: 640...670nm IEC 60825-1, Ed. 3, 2014 CLASS 2 LASER PRODUCT mechanical data width / diameter 26 mm height / length 74 mm depth 55 mm type rectangular, front view housing material aluminum front (optics) glass connection types connector M12 8 pin OM70-X0500.HI0660.VI Z GN (3) Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50, dated June 24, 2007 www.baumer.com 30/5/2016 Photoelectric sensors OM70-X0500.HI0660.VI OM70-11112069 Distance sensors ambient conditions ambient light immunity < 35 kLux operating temperature -10 ... +50 °C protection class IP 67 storage temperature -25 ... +75 °C vibration (sinusoidal) IEC 60068-2-6:2008 1.5 mm p-p at f = 10 - 57 Hz, 10 cycles per axis 10 g at f = 58 - 2000 Hz, 10 cycles per axis IEC 60068-2-27:2009 50 g / 11 ms resp. 100 g / 6 ms, 10 jolts per axis and direction 100 g / 2 ms, 5000 jolts per axis and direction shock (semi-sinusoidal) 1) Measurement with Baumer standardized measuring equipment and targets depending on measuring distance Sd 2) Measurement on 90% remission (white) 3) Measurement with reduced Field of View (distance 400 ... 500 mm, width 5 mm) 4) Measurement with measuring type average 5) Measurement with filtering 6) Measuring range (distance) 100 ... 200 mm OM70-X0500.HI0660.VI www.baumer.com 30/5/2016