LITTELFUSE FLM25

Axial Lead and Cartridge Fuses
Midget
250 Volt Slo-Blo Type Fuse FLM Series
U® L
®
®
QPL
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
135%
200%
Ampere
Rating
1/10-30
32/10 –30
0–3
Opening
Time
1 hour, Maximum
12 seconds, Minimum
5 seconds, Minimum
AGENCY APPROVALS: Listed by Underwriters Laboratories
and Certified by CSA.
INTERRUPTING RATING: 10,000 amperes at 250 VAC.
FUSES TO MIL SPEC: See F09B type in Military Section.
PATENTED
ORDERING INFORMATION:
38.1
(1.50")
1000
8A
10A
15A
20A
25A
30A
Average Time Current Curves
100
10
1
0.1
0.01
442
10.31
(.406")
1A
1 1/2A
2A
Nominal
Resistance
Cold Ohms
188.0
87.0
35.109
5.413
3.79
2.10
1.54
1.024
.623
.395
.356
.286
.253
.219
.184
.162
.125
.102
.0904
.0735
.0700
.0576
.0517
.0426
.0360
.0413
.0326
.0280
.0277
.02133
.01247
.01066
.00903
.00698
.00530
.00385
.00275
.00226
1/2A
AC Voltage
Rating
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
1/10A
15/100A
1/4A
Ampere
Rating
.100
.150
.200
.250
.300
.400
.500
.600
.800
1
1.125
1.25
1.4
1.5
1.6
1.8
2
2.25
2.5
2.8
3
3.2
3.5
4
4.5
5
5.6
6
6.25
7
8
9
10
12
15
20
25
30
TIME IN SECONDS
Cartridge
Catalog
Number
FLM 1/10
FLM 15/100
FLM 2/10
FLM 1/4
FLM 3/10
FLM 4/10
FLM 1/2
FLM 6/10
FLM 8/10
FLM 1
FLM 11/8
FLM 11/4
FLM 14/10
FLM 11/2
FLM 16/10
FLM 18/10
FLM 2
FLM 21/4
FLM 21/2
FLM 28/10
FLM 3
FLM 32/10
FLM 31/2
FLM 4
FLM 41/2
FLM 5
FLM 56/10
FLM 6
FLM 61/4
FLM 7
FLM 8
FLM 9
FLM 10
FLM 12
FLM 15
FLM 20
FLM 25
FLM 30
w w w. l i t t e l f u s e . c o m
0.1
1
10
CURRENT IN AMPERES
100