EN

Photoelectric sensors
OADM 260I1101/S14C
Distance sensors
dimension drawing
51
4,5
39,5
7
56
3
5,5
13
2
* 52,6
66
4,4
LED
4,5
25,4
M12 x 1
* emitter axis
general data
photo
measuring distance Sd
200 ... 13000 mm
measuring distance Sd (white 90%)
200 ... 13000 mm
measuring distance Sd (grey 18%)
200 ... 9000 mm
measuring distance Sd (black 6%)
200 ... 4000 mm
adjustment
Teach-in: button / external
Teach-in range min.
> 100 mm
power on indication
LED green
soiled lens indicator
LED red
resolution
5 mm
linearity
± 15 mm
repeatability
± 15 mm (with 40 kLux ambient light)
light source
pulsed red laser diode
wave length
660 nm
laser class
2
beam type
point
beam diameter
5 ... 50 mm
connection diagram
electrical data
measuring rate
10 ms
voltage supply range +Vs
15 ... 28 VDC
current consumption max. (no load)
250 mA (typ. 110 mA @ 24V)
output circuit
analog
output signal
4 ... 20 mA
load resistance (analog I)
< (+Vs - 6 V) / 0,02 A
output current
< 100 mA
alarm output
push-pull
short circuit protection
yes
reverse polarity protection
yes, Vs to GND
BU (3)
Z
Z
+VS
analog
alarm
ext. teach
0V
laser warning
LASER RADIATION
DO NOT STARE INTO BEAM
Wavelength: 620...680nm
Max. av. Output: < 1mW
IEC 60825-1, Ed. 2, 2007
CLASS 2 LASER PRODUCT
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice No. 50, dated June 24, 2007
mechanical data
width / diameter
25,4 mm
height / length
66 mm
depth
51 mm
type
rectangular
housing material
aluminum
front (optics)
glass
connection types
connector M12 5 pin, rotatable
OADM 260I1101/S14C
Analog
Push Pull
BN (1)
WH (2)
BK (4)
GY (5)
www.baumer.com
28/4/2015
Photoelectric sensors
OADM 260I1101/S14C
Distance sensors
ambient conditions
ambient light immunity
< 40 kLux
operating temperature
-25 ... +50 °C
protection class
IP 67
typ. temp. coefficient
0,4 mm /°C
OADM 260I1101/S14C
www.baumer.com
28/4/2015