data sheet - family

Ultrasonic sensors
UNAM 50
Ultrasonic distance measuring
sensors
sample drawing
58,5
70
SW 36
95
14,2
ø 44,5
M30 x 1,5
LED
11
Teach-in
M12 x 1
Teach-in = Teach-in or potentiometer
general data
sample picture
scanning range sd
400 ... 2500 mm
scanning range close limit Sdc
400 ... 2500 mm
scanning range far limit Sde
400 ... 2500 mm
repeat accuracy
< 1 mm
resolution
< 0,3 mm
response time ton
< 160 ms
release time toff
< 160 ms
temperature drift
< 2 % of distance to target So
sonic frequency
120 kHz
adjustment
Teach-in
alignment aid
target indication flashing
light indicator
yellow LED / red LED
electrical data
voltage supply range +Vs
15 ... 30 VDC
output current
< 20 mA
residual ripple
< 10 % Vs
short circuit protection
yes
reverse polarity protection
yes
voltage output
current consumption max. (no load)
35 mA
output signal
0 ... 10 V / 10 ... 0 V
current output
current consumption max. (no load)
55 mA
output signal
4 ... 20 mA / 20 ... 4 mA
load resistance +Vs max.
< 1100 Ohm
load resistance +Vs min.
< 400 Ohm
mechanical data
type
cylindrical threaded
housing material
brass nickel plated
width / diameter
30 mm
height / length
95 mm
ambient conditions
operating temperature
-10 ... +60 °C
protection class
IP 67
1
www.baumer.com
2/6/2015
Ultrasonic sensors
UNAM 50
Ultrasonic distance measuring
sensors
order reference
output circuit
connection types
UNAM 50I6121
current output
cable, 2 m
UNAM 50I6121/S14
current output
connector M12
UNAM 50U6121
voltage output
cable, 2 m
UNAM 50U6121/S14
voltage output
connector M12
2
www.baumer.com
2/6/2015